Cargando…

Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNO(3) for the Accurate Detection of Low X-ray Doses

Currently, the uncontrolled exposure of individuals to X-rays during medical examinations represents a substantial danger that threatens both medical professionals and patients. Therefore, radiation dosimetry for low X-ray doses is a very important control of radiation practice in medical diagnostic...

Descripción completa

Detalles Bibliográficos
Autores principales: Alashrah, Saleh, El-Ghoul, Yassine, Almutairi, Faisal Muteb, Omer, Mohammed Ahmed Ali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473152/
https://www.ncbi.nlm.nih.gov/pubmed/34578041
http://dx.doi.org/10.3390/polym13183140
_version_ 1784574917767856128
author Alashrah, Saleh
El-Ghoul, Yassine
Almutairi, Faisal Muteb
Omer, Mohammed Ahmed Ali
author_facet Alashrah, Saleh
El-Ghoul, Yassine
Almutairi, Faisal Muteb
Omer, Mohammed Ahmed Ali
author_sort Alashrah, Saleh
collection PubMed
description Currently, the uncontrolled exposure of individuals to X-rays during medical examinations represents a substantial danger that threatens both medical professionals and patients. Therefore, radiation dosimetry for low X-ray doses is a very important control of radiation practice in medical diagnostic radiology. In line with this, the current study proposes a valuable dosimeter-based PVA thin film doubly doped with silver nitrate salt and nitro blue tetrazolium dye. The nanocomposite film was prepared via a simple casting method and the different processing parameters were optimized. The performance of radiation detection was evaluated according to optical, chromic, chemical and structural changes after exposure to variable low X-ray doses (0, 2, 4, 10 and 20 mGy). The different film labels exhibited an excellent stability behavior in dark and light upon 30 days of storage. The UV-Vis spectrophotometric study showed a gradual increase in the maximum absorbance as a function of the dose and the corresponding response curve confirmed this linear variation (R = 0.998). A clear structural modification was recorded via X-ray diffraction (XRD) analysis revealing the increase in crystallinity with the level of the dose received by the nanocomposite films. Microscopic surface analysis via SEM assessments revealed a significant morphological change in PVA/Ag(+)/NBT films exposed to increased radiation doses and typical dendrites growing in needle- or tree-like microstructures appeared with a high X-ray dose. Finally, the nanocomposite films before and after irradiation were evaluated via a spectrocolorimetric study and the different CIELab coordinates, the color difference, as well as the color strength, showed a linear correlation with the intensity of the applied dose. This new dosimeter design could, therefore, provide a promising and efficient alternative for prompt and accurate detection of low X-rays doses in diagnostic radiology.
format Online
Article
Text
id pubmed-8473152
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84731522021-09-28 Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNO(3) for the Accurate Detection of Low X-ray Doses Alashrah, Saleh El-Ghoul, Yassine Almutairi, Faisal Muteb Omer, Mohammed Ahmed Ali Polymers (Basel) Article Currently, the uncontrolled exposure of individuals to X-rays during medical examinations represents a substantial danger that threatens both medical professionals and patients. Therefore, radiation dosimetry for low X-ray doses is a very important control of radiation practice in medical diagnostic radiology. In line with this, the current study proposes a valuable dosimeter-based PVA thin film doubly doped with silver nitrate salt and nitro blue tetrazolium dye. The nanocomposite film was prepared via a simple casting method and the different processing parameters were optimized. The performance of radiation detection was evaluated according to optical, chromic, chemical and structural changes after exposure to variable low X-ray doses (0, 2, 4, 10 and 20 mGy). The different film labels exhibited an excellent stability behavior in dark and light upon 30 days of storage. The UV-Vis spectrophotometric study showed a gradual increase in the maximum absorbance as a function of the dose and the corresponding response curve confirmed this linear variation (R = 0.998). A clear structural modification was recorded via X-ray diffraction (XRD) analysis revealing the increase in crystallinity with the level of the dose received by the nanocomposite films. Microscopic surface analysis via SEM assessments revealed a significant morphological change in PVA/Ag(+)/NBT films exposed to increased radiation doses and typical dendrites growing in needle- or tree-like microstructures appeared with a high X-ray dose. Finally, the nanocomposite films before and after irradiation were evaluated via a spectrocolorimetric study and the different CIELab coordinates, the color difference, as well as the color strength, showed a linear correlation with the intensity of the applied dose. This new dosimeter design could, therefore, provide a promising and efficient alternative for prompt and accurate detection of low X-rays doses in diagnostic radiology. MDPI 2021-09-17 /pmc/articles/PMC8473152/ /pubmed/34578041 http://dx.doi.org/10.3390/polym13183140 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Alashrah, Saleh
El-Ghoul, Yassine
Almutairi, Faisal Muteb
Omer, Mohammed Ahmed Ali
Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNO(3) for the Accurate Detection of Low X-ray Doses
title Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNO(3) for the Accurate Detection of Low X-ray Doses
title_full Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNO(3) for the Accurate Detection of Low X-ray Doses
title_fullStr Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNO(3) for the Accurate Detection of Low X-ray Doses
title_full_unstemmed Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNO(3) for the Accurate Detection of Low X-ray Doses
title_short Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNO(3) for the Accurate Detection of Low X-ray Doses
title_sort development, characterization and valuable use of novel dosimeter film based on pva polymer doped nitro blue tetrazolium dye and agno(3) for the accurate detection of low x-ray doses
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473152/
https://www.ncbi.nlm.nih.gov/pubmed/34578041
http://dx.doi.org/10.3390/polym13183140
work_keys_str_mv AT alashrahsaleh developmentcharacterizationandvaluableuseofnoveldosimeterfilmbasedonpvapolymerdopednitrobluetetrazoliumdyeandagno3fortheaccuratedetectionoflowxraydoses
AT elghoulyassine developmentcharacterizationandvaluableuseofnoveldosimeterfilmbasedonpvapolymerdopednitrobluetetrazoliumdyeandagno3fortheaccuratedetectionoflowxraydoses
AT almutairifaisalmuteb developmentcharacterizationandvaluableuseofnoveldosimeterfilmbasedonpvapolymerdopednitrobluetetrazoliumdyeandagno3fortheaccuratedetectionoflowxraydoses
AT omermohammedahmedali developmentcharacterizationandvaluableuseofnoveldosimeterfilmbasedonpvapolymerdopednitrobluetetrazoliumdyeandagno3fortheaccuratedetectionoflowxraydoses