Cargando…
Development and Evaluation of an Improved Apparatus for Measuring the Emissivity at High Temperatures
An improved apparatus for measuring the spectral directional emissivity in the wavelength range between 1 µm and 20 µm at temperatures up to 2400 K is presented in this paper. As a heating unit an inductor is used to warm up the specimen, as well as the blackbody reference to the specified temperatu...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473261/ https://www.ncbi.nlm.nih.gov/pubmed/34577459 http://dx.doi.org/10.3390/s21186252 |
_version_ | 1784574947696312320 |
---|---|
author | Arduini, Mariacarla Manara, Jochen Stark, Thomas Ebert, Hans-Peter Hartmann, Jürgen |
author_facet | Arduini, Mariacarla Manara, Jochen Stark, Thomas Ebert, Hans-Peter Hartmann, Jürgen |
author_sort | Arduini, Mariacarla |
collection | PubMed |
description | An improved apparatus for measuring the spectral directional emissivity in the wavelength range between 1 µm and 20 µm at temperatures up to 2400 K is presented in this paper. As a heating unit an inductor is used to warm up the specimen, as well as the blackbody reference to the specified temperatures. The heating unit is placed in a double-walled vacuum vessel. A defined temperature, as well as a homogenous temperature distribution of the whole surrounding is ensured by a heat transfer fluid flowing through the gap of the double-walled vessel. Additionally, the surrounding is coated with a high-emitting paint and serves as blackbody-like surrounding to ensure defined boundary conditions. For measuring the spectral directional emissivity at different emission angles, a movable mirror is installed in front of the specimen, which can be adjusted by a rotatable arrangement guiding the emitted radiation into the attached FTIR-spectrometer. The setup of the emissivity measurement apparatus (EMMA) and the measurement procedure are introduced, and the derived measurement results are presented. For evaluating the apparatus, measurements were performed on different materials. The determined emissivities agree well with values published in literature within the derived relative uncertainties below 4% for most wavelengths. |
format | Online Article Text |
id | pubmed-8473261 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84732612021-09-28 Development and Evaluation of an Improved Apparatus for Measuring the Emissivity at High Temperatures Arduini, Mariacarla Manara, Jochen Stark, Thomas Ebert, Hans-Peter Hartmann, Jürgen Sensors (Basel) Article An improved apparatus for measuring the spectral directional emissivity in the wavelength range between 1 µm and 20 µm at temperatures up to 2400 K is presented in this paper. As a heating unit an inductor is used to warm up the specimen, as well as the blackbody reference to the specified temperatures. The heating unit is placed in a double-walled vacuum vessel. A defined temperature, as well as a homogenous temperature distribution of the whole surrounding is ensured by a heat transfer fluid flowing through the gap of the double-walled vessel. Additionally, the surrounding is coated with a high-emitting paint and serves as blackbody-like surrounding to ensure defined boundary conditions. For measuring the spectral directional emissivity at different emission angles, a movable mirror is installed in front of the specimen, which can be adjusted by a rotatable arrangement guiding the emitted radiation into the attached FTIR-spectrometer. The setup of the emissivity measurement apparatus (EMMA) and the measurement procedure are introduced, and the derived measurement results are presented. For evaluating the apparatus, measurements were performed on different materials. The determined emissivities agree well with values published in literature within the derived relative uncertainties below 4% for most wavelengths. MDPI 2021-09-17 /pmc/articles/PMC8473261/ /pubmed/34577459 http://dx.doi.org/10.3390/s21186252 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Arduini, Mariacarla Manara, Jochen Stark, Thomas Ebert, Hans-Peter Hartmann, Jürgen Development and Evaluation of an Improved Apparatus for Measuring the Emissivity at High Temperatures |
title | Development and Evaluation of an Improved Apparatus for Measuring the Emissivity at High Temperatures |
title_full | Development and Evaluation of an Improved Apparatus for Measuring the Emissivity at High Temperatures |
title_fullStr | Development and Evaluation of an Improved Apparatus for Measuring the Emissivity at High Temperatures |
title_full_unstemmed | Development and Evaluation of an Improved Apparatus for Measuring the Emissivity at High Temperatures |
title_short | Development and Evaluation of an Improved Apparatus for Measuring the Emissivity at High Temperatures |
title_sort | development and evaluation of an improved apparatus for measuring the emissivity at high temperatures |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473261/ https://www.ncbi.nlm.nih.gov/pubmed/34577459 http://dx.doi.org/10.3390/s21186252 |
work_keys_str_mv | AT arduinimariacarla developmentandevaluationofanimprovedapparatusformeasuringtheemissivityathightemperatures AT manarajochen developmentandevaluationofanimprovedapparatusformeasuringtheemissivityathightemperatures AT starkthomas developmentandevaluationofanimprovedapparatusformeasuringtheemissivityathightemperatures AT eberthanspeter developmentandevaluationofanimprovedapparatusformeasuringtheemissivityathightemperatures AT hartmannjurgen developmentandevaluationofanimprovedapparatusformeasuringtheemissivityathightemperatures |