Indoor environmental conditions can significantly affect occupants’ health and comfort. These conditions are especially important in educational buildings, where students, teachers and staff spend long periods of the day and are vulnerable to these factors. Recently, indoor air quality has been a fo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473345/ https://www.ncbi.nlm.nih.gov/pubmed/34577328 http://dx.doi.org/10.3390/s21186122 |
_version_ | 1784574968478040064 |
---|---|
author | de la Hoz-Torres, María L. Aguilar, Antonio J. Ruiz, Diego P. Martínez-Aires, María Dolores |
author_facet | de la Hoz-Torres, María L. Aguilar, Antonio J. Ruiz, Diego P. Martínez-Aires, María Dolores |
author_sort | de la Hoz-Torres, María L. |
collection | PubMed |
description | Indoor environmental conditions can significantly affect occupants’ health and comfort. These conditions are especially important in educational buildings, where students, teachers and staff spend long periods of the day and are vulnerable to these factors. Recently, indoor air quality has been a focus of attention to ensure that disease transmission in these spaces is minimised. In order to increase the knowledge in this field, experimental tests have been carried out to characterise the impact of natural ventilation strategies on indoor air quality and the acoustic environment. This study has evaluated three ventilation scenarios in four different classrooms in buildings of the University of Granada, considering different window and door opening configurations. Ventilation rates were estimated using the CO(2) Decay Method, and background noise recordings were made in each classroom for acoustic tests. Results show that specific natural ventilation strategies have a relevant impact that is worth considering on the background noise in indoor spaces. In this sense ventilation rates provided by the different configurations varied between 3.7 and 39.8 air changes per hour (ACH) and the acoustic tests show a background noise ranging from 43 to 54 dBA in these scenarios. Consequently, managers and teachers should take into account not only the ACH, but also other collateral impacts on the indoor environmental conditions such as the thermal comfort or the acoustic environment. |
format | Online Article Text |
id | pubmed-8473345 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84733452021-09-28 Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings de la Hoz-Torres, María L. Aguilar, Antonio J. Ruiz, Diego P. Martínez-Aires, María Dolores Sensors (Basel) Article Indoor environmental conditions can significantly affect occupants’ health and comfort. These conditions are especially important in educational buildings, where students, teachers and staff spend long periods of the day and are vulnerable to these factors. Recently, indoor air quality has been a focus of attention to ensure that disease transmission in these spaces is minimised. In order to increase the knowledge in this field, experimental tests have been carried out to characterise the impact of natural ventilation strategies on indoor air quality and the acoustic environment. This study has evaluated three ventilation scenarios in four different classrooms in buildings of the University of Granada, considering different window and door opening configurations. Ventilation rates were estimated using the CO(2) Decay Method, and background noise recordings were made in each classroom for acoustic tests. Results show that specific natural ventilation strategies have a relevant impact that is worth considering on the background noise in indoor spaces. In this sense ventilation rates provided by the different configurations varied between 3.7 and 39.8 air changes per hour (ACH) and the acoustic tests show a background noise ranging from 43 to 54 dBA in these scenarios. Consequently, managers and teachers should take into account not only the ACH, but also other collateral impacts on the indoor environmental conditions such as the thermal comfort or the acoustic environment. MDPI 2021-09-12 /pmc/articles/PMC8473345/ /pubmed/34577328 http://dx.doi.org/10.3390/s21186122 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article de la Hoz-Torres, María L. Aguilar, Antonio J. Ruiz, Diego P. Martínez-Aires, María Dolores Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings |
title | Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings |
title_full | Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings |
title_fullStr | Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings |
title_full_unstemmed | Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings |
title_short | Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings |
title_sort | analysis of impact of natural ventilation strategies in ventilation rates and indoor environmental acoustics using sensor measurement data in educational buildings |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473345/ https://www.ncbi.nlm.nih.gov/pubmed/34577328 http://dx.doi.org/10.3390/s21186122 |
work_keys_str_mv | AT delahoztorresmarial analysisofimpactofnaturalventilationstrategiesinventilationratesandindoorenvironmentalacousticsusingsensormeasurementdataineducationalbuildings AT aguilarantonioj analysisofimpactofnaturalventilationstrategiesinventilationratesandindoorenvironmentalacousticsusingsensormeasurementdataineducationalbuildings AT ruizdiegop analysisofimpactofnaturalventilationstrategiesinventilationratesandindoorenvironmentalacousticsusingsensormeasurementdataineducationalbuildings AT martinezairesmariadolores analysisofimpactofnaturalventilationstrategiesinventilationratesandindoorenvironmentalacousticsusingsensormeasurementdataineducationalbuildings |