Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings

Indoor environmental conditions can significantly affect occupants’ health and comfort. These conditions are especially important in educational buildings, where students, teachers and staff spend long periods of the day and are vulnerable to these factors. Recently, indoor air quality has been a fo...

Descripción completa

Detalles Bibliográficos
Autores principales: de la Hoz-Torres, María L., Aguilar, Antonio J., Ruiz, Diego P., Martínez-Aires, María Dolores
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473345/
https://www.ncbi.nlm.nih.gov/pubmed/34577328
http://dx.doi.org/10.3390/s21186122
_version_ 1784574968478040064
author de la Hoz-Torres, María L.
Aguilar, Antonio J.
Ruiz, Diego P.
Martínez-Aires, María Dolores
author_facet de la Hoz-Torres, María L.
Aguilar, Antonio J.
Ruiz, Diego P.
Martínez-Aires, María Dolores
author_sort de la Hoz-Torres, María L.
collection PubMed
description Indoor environmental conditions can significantly affect occupants’ health and comfort. These conditions are especially important in educational buildings, where students, teachers and staff spend long periods of the day and are vulnerable to these factors. Recently, indoor air quality has been a focus of attention to ensure that disease transmission in these spaces is minimised. In order to increase the knowledge in this field, experimental tests have been carried out to characterise the impact of natural ventilation strategies on indoor air quality and the acoustic environment. This study has evaluated three ventilation scenarios in four different classrooms in buildings of the University of Granada, considering different window and door opening configurations. Ventilation rates were estimated using the CO(2) Decay Method, and background noise recordings were made in each classroom for acoustic tests. Results show that specific natural ventilation strategies have a relevant impact that is worth considering on the background noise in indoor spaces. In this sense ventilation rates provided by the different configurations varied between 3.7 and 39.8 air changes per hour (ACH) and the acoustic tests show a background noise ranging from 43 to 54 dBA in these scenarios. Consequently, managers and teachers should take into account not only the ACH, but also other collateral impacts on the indoor environmental conditions such as the thermal comfort or the acoustic environment.
format Online
Article
Text
id pubmed-8473345
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84733452021-09-28 Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings de la Hoz-Torres, María L. Aguilar, Antonio J. Ruiz, Diego P. Martínez-Aires, María Dolores Sensors (Basel) Article Indoor environmental conditions can significantly affect occupants’ health and comfort. These conditions are especially important in educational buildings, where students, teachers and staff spend long periods of the day and are vulnerable to these factors. Recently, indoor air quality has been a focus of attention to ensure that disease transmission in these spaces is minimised. In order to increase the knowledge in this field, experimental tests have been carried out to characterise the impact of natural ventilation strategies on indoor air quality and the acoustic environment. This study has evaluated three ventilation scenarios in four different classrooms in buildings of the University of Granada, considering different window and door opening configurations. Ventilation rates were estimated using the CO(2) Decay Method, and background noise recordings were made in each classroom for acoustic tests. Results show that specific natural ventilation strategies have a relevant impact that is worth considering on the background noise in indoor spaces. In this sense ventilation rates provided by the different configurations varied between 3.7 and 39.8 air changes per hour (ACH) and the acoustic tests show a background noise ranging from 43 to 54 dBA in these scenarios. Consequently, managers and teachers should take into account not only the ACH, but also other collateral impacts on the indoor environmental conditions such as the thermal comfort or the acoustic environment. MDPI 2021-09-12 /pmc/articles/PMC8473345/ /pubmed/34577328 http://dx.doi.org/10.3390/s21186122 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
de la Hoz-Torres, María L.
Aguilar, Antonio J.
Ruiz, Diego P.
Martínez-Aires, María Dolores
Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings
title Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings
title_full Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings
title_fullStr Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings
title_full_unstemmed Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings
title_short Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings
title_sort analysis of impact of natural ventilation strategies in ventilation rates and indoor environmental acoustics using sensor measurement data in educational buildings
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473345/
https://www.ncbi.nlm.nih.gov/pubmed/34577328
http://dx.doi.org/10.3390/s21186122
work_keys_str_mv AT delahoztorresmarial analysisofimpactofnaturalventilationstrategiesinventilationratesandindoorenvironmentalacousticsusingsensormeasurementdataineducationalbuildings
AT aguilarantonioj analysisofimpactofnaturalventilationstrategiesinventilationratesandindoorenvironmentalacousticsusingsensormeasurementdataineducationalbuildings
AT ruizdiegop analysisofimpactofnaturalventilationstrategiesinventilationratesandindoorenvironmentalacousticsusingsensormeasurementdataineducationalbuildings
AT martinezairesmariadolores analysisofimpactofnaturalventilationstrategiesinventilationratesandindoorenvironmentalacousticsusingsensormeasurementdataineducationalbuildings