Cargando…

Benefits of a Switch from Intermittently Scanned Continuous Glucose Monitoring (isCGM) to Real-Time (rt) CGM in Diabetes Type 1 Suboptimal Controlled Patients in Real-Life: A One-Year Prospective Study (§)

The switch from intermittently scanned continuous glucose monitoring (isCGM) to real-time (rt) CGM could improve glycemic management in suboptimal controlled type 1 diabetes patients, but long-term study is lacking. We evaluated retrospectively the ambulatory glucose profile (AGP) in such patients a...

Descripción completa

Detalles Bibliográficos
Autores principales: Préau, Yannis, Galie, Sébastien, Schaepelynck, Pauline, Armand, Martine, Raccah, Denis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473395/
https://www.ncbi.nlm.nih.gov/pubmed/34577338
http://dx.doi.org/10.3390/s21186131
_version_ 1784574981200412672
author Préau, Yannis
Galie, Sébastien
Schaepelynck, Pauline
Armand, Martine
Raccah, Denis
author_facet Préau, Yannis
Galie, Sébastien
Schaepelynck, Pauline
Armand, Martine
Raccah, Denis
author_sort Préau, Yannis
collection PubMed
description The switch from intermittently scanned continuous glucose monitoring (isCGM) to real-time (rt) CGM could improve glycemic management in suboptimal controlled type 1 diabetes patients, but long-term study is lacking. We evaluated retrospectively the ambulatory glucose profile (AGP) in such patients after switching from Free Style Libre 1 (FSL1) to Dexcom G4 (DG4) biosensors over 1 year. Patients (n = 21, 43 ± 15 years, BMI 25 ± 5, HbA1c 8.1 ± 1.0%) had severe hypoglycemia and/or HbA1c ≥ 8%. AGP metrics (time-in-range (TIR) 70–180 mg/dL, time-below-range (TBR) <70 mg/dL or <54 mg/dL, glucose coefficient of variation (%CV), time-above-range (TAR) >180 mg/dL or >250 mg/dL, glucose management indicator (GMI), average glucose) were collected the last 3 months of FSL1 use (M0) and of DG4 for 3, 6 (M6) and 12 (M12) months of use. Values were means ± standard deviation or medians [Q1;Q3]. At M12 versus M0, the higher TIR (50 ± 17 vs. 45 ± 16, p = 0.036), and lower TBR < 70 mg/dL (2.5 [1.6;5.5] vs. 7.0 [4.5;12.5], p = 0.0007), TBR < 54 mg/dL (0.7 [0.4;0.8] vs. 2.3 [0.8;7.0], p = 0.007) and %CV (39 ± 5 vs. 45 ± 8, p = 0.0009), evidenced a long-term effectiveness of the switch. Compared to M6, TBR < 70 mg/dL decreased, %CV remained stable, while the improvement on hyperglycemia exposure decreased (higher GMI, TAR and average glucose). This switch was a relevant therapeutic option, though a loss of benefit on hyperglycemia stressed the need for optimized management of threshold alarms. Nevertheless, few patients attained the recommended values for AGP metrics, and the reasons why some patients are “responders” vs. “non-responders” warrant to be investigated.
format Online
Article
Text
id pubmed-8473395
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84733952021-09-28 Benefits of a Switch from Intermittently Scanned Continuous Glucose Monitoring (isCGM) to Real-Time (rt) CGM in Diabetes Type 1 Suboptimal Controlled Patients in Real-Life: A One-Year Prospective Study (§) Préau, Yannis Galie, Sébastien Schaepelynck, Pauline Armand, Martine Raccah, Denis Sensors (Basel) Article The switch from intermittently scanned continuous glucose monitoring (isCGM) to real-time (rt) CGM could improve glycemic management in suboptimal controlled type 1 diabetes patients, but long-term study is lacking. We evaluated retrospectively the ambulatory glucose profile (AGP) in such patients after switching from Free Style Libre 1 (FSL1) to Dexcom G4 (DG4) biosensors over 1 year. Patients (n = 21, 43 ± 15 years, BMI 25 ± 5, HbA1c 8.1 ± 1.0%) had severe hypoglycemia and/or HbA1c ≥ 8%. AGP metrics (time-in-range (TIR) 70–180 mg/dL, time-below-range (TBR) <70 mg/dL or <54 mg/dL, glucose coefficient of variation (%CV), time-above-range (TAR) >180 mg/dL or >250 mg/dL, glucose management indicator (GMI), average glucose) were collected the last 3 months of FSL1 use (M0) and of DG4 for 3, 6 (M6) and 12 (M12) months of use. Values were means ± standard deviation or medians [Q1;Q3]. At M12 versus M0, the higher TIR (50 ± 17 vs. 45 ± 16, p = 0.036), and lower TBR < 70 mg/dL (2.5 [1.6;5.5] vs. 7.0 [4.5;12.5], p = 0.0007), TBR < 54 mg/dL (0.7 [0.4;0.8] vs. 2.3 [0.8;7.0], p = 0.007) and %CV (39 ± 5 vs. 45 ± 8, p = 0.0009), evidenced a long-term effectiveness of the switch. Compared to M6, TBR < 70 mg/dL decreased, %CV remained stable, while the improvement on hyperglycemia exposure decreased (higher GMI, TAR and average glucose). This switch was a relevant therapeutic option, though a loss of benefit on hyperglycemia stressed the need for optimized management of threshold alarms. Nevertheless, few patients attained the recommended values for AGP metrics, and the reasons why some patients are “responders” vs. “non-responders” warrant to be investigated. MDPI 2021-09-13 /pmc/articles/PMC8473395/ /pubmed/34577338 http://dx.doi.org/10.3390/s21186131 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Préau, Yannis
Galie, Sébastien
Schaepelynck, Pauline
Armand, Martine
Raccah, Denis
Benefits of a Switch from Intermittently Scanned Continuous Glucose Monitoring (isCGM) to Real-Time (rt) CGM in Diabetes Type 1 Suboptimal Controlled Patients in Real-Life: A One-Year Prospective Study (§)
title Benefits of a Switch from Intermittently Scanned Continuous Glucose Monitoring (isCGM) to Real-Time (rt) CGM in Diabetes Type 1 Suboptimal Controlled Patients in Real-Life: A One-Year Prospective Study (§)
title_full Benefits of a Switch from Intermittently Scanned Continuous Glucose Monitoring (isCGM) to Real-Time (rt) CGM in Diabetes Type 1 Suboptimal Controlled Patients in Real-Life: A One-Year Prospective Study (§)
title_fullStr Benefits of a Switch from Intermittently Scanned Continuous Glucose Monitoring (isCGM) to Real-Time (rt) CGM in Diabetes Type 1 Suboptimal Controlled Patients in Real-Life: A One-Year Prospective Study (§)
title_full_unstemmed Benefits of a Switch from Intermittently Scanned Continuous Glucose Monitoring (isCGM) to Real-Time (rt) CGM in Diabetes Type 1 Suboptimal Controlled Patients in Real-Life: A One-Year Prospective Study (§)
title_short Benefits of a Switch from Intermittently Scanned Continuous Glucose Monitoring (isCGM) to Real-Time (rt) CGM in Diabetes Type 1 Suboptimal Controlled Patients in Real-Life: A One-Year Prospective Study (§)
title_sort benefits of a switch from intermittently scanned continuous glucose monitoring (iscgm) to real-time (rt) cgm in diabetes type 1 suboptimal controlled patients in real-life: a one-year prospective study (§)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473395/
https://www.ncbi.nlm.nih.gov/pubmed/34577338
http://dx.doi.org/10.3390/s21186131
work_keys_str_mv AT preauyannis benefitsofaswitchfromintermittentlyscannedcontinuousglucosemonitoringiscgmtorealtimertcgmindiabetestype1suboptimalcontrolledpatientsinreallifeaoneyearprospectivestudy
AT galiesebastien benefitsofaswitchfromintermittentlyscannedcontinuousglucosemonitoringiscgmtorealtimertcgmindiabetestype1suboptimalcontrolledpatientsinreallifeaoneyearprospectivestudy
AT schaepelynckpauline benefitsofaswitchfromintermittentlyscannedcontinuousglucosemonitoringiscgmtorealtimertcgmindiabetestype1suboptimalcontrolledpatientsinreallifeaoneyearprospectivestudy
AT armandmartine benefitsofaswitchfromintermittentlyscannedcontinuousglucosemonitoringiscgmtorealtimertcgmindiabetestype1suboptimalcontrolledpatientsinreallifeaoneyearprospectivestudy
AT raccahdenis benefitsofaswitchfromintermittentlyscannedcontinuousglucosemonitoringiscgmtorealtimertcgmindiabetestype1suboptimalcontrolledpatientsinreallifeaoneyearprospectivestudy