Cargando…

Characterization of Aerosol Generation During Various Intensities of Exercise

BACKGROUND: Characterization of aerosol generation during exercise can inform the development of safety recommendations in the face of COVID-19. RESEARCH QUESTION: Does exercise at various intensities produce aerosols in significant quantities? STUDY DESIGN AND METHODS: In this experimental study, s...

Descripción completa

Detalles Bibliográficos
Autores principales: Sajgalik, Pavol, Garzona-Navas, Andres, Csécs, Ibolya, Askew, J. Wells, Lopez-Jimenez, Francisco, Niven, Alexander S., Johnson, Bruce D., Allison, Thomas G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American College of Chest Physicians. Published by Elsevier Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473677/
https://www.ncbi.nlm.nih.gov/pubmed/33957100
http://dx.doi.org/10.1016/j.chest.2021.04.041
Descripción
Sumario:BACKGROUND: Characterization of aerosol generation during exercise can inform the development of safety recommendations in the face of COVID-19. RESEARCH QUESTION: Does exercise at various intensities produce aerosols in significant quantities? STUDY DESIGN AND METHODS: In this experimental study, subjects were eight healthy volunteers (six men, two women) who were 20 to 63 years old. The 20-minute test protocol of 5 minutes rest, four 3-minute stages of exercise at 25%, 50%, 75%, and 100% of age-predicted heart rate reserve, and 3 minutes active recovery was performed in a clean, controlled environment. Aerosols were measured by four particle counters that were place to surround the subject. RESULTS: Age averaged 41 ± 14 years. Peak heart rate was 173 ± 17 beat/min (97% predicted); peak maximal oxygen uptake was 33.9 ± 7.5 mL/kg/min; and peak respiratory exchange ratio was 1.22 ± 0.10. Maximal ventilation averaged 120 ± 23 L/min, while cumulative ventilation reached 990 ± 192 L. Concentrations increased exponentially from start to 20 minutes (geometric mean ± geometric SD particles/liter): Fluke >0.3 μm = 66 ± 1.8 → 1605 ± 3.8; 0.3-1.0 μm = 35 ± 2.2 → 1095 ± 4.6; Fluke 1.0-5.0 μm = 21 ± 2.0 → 358 ± 2.3; P-Trak anterior = 637 ± 2.3 → 5148 ± 3.0; P-Trak side = 708 ± 2.7 → 6844 ± 2.7; P-Track back = 519 ± 3.1 → 5853 ± 2.8. All increases were significant at a probability value of <.05. Exercise at or above 50% of predicted heart rate reserve showed statistically significant increases in aerosol concentration. INTERPRETATION: Our data suggest exercise testing is an aerosol-generating procedure and, by extension, other activities that involve exercise intensities at or above 50% of predicted heart rate reserve. Results can guide recommendations for safety of exercise testing and other indoor exercise activities.