Cargando…
Control of the temperature responsiveness of poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) copolymer using ultrasonic irradiation
Poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) (poly(NIPAM-co-HEMA)) is a temperature-responsive copolymer that is expected to be applicable as an advanced functional polymeric material in various fields. In this study, a novel method was developed to control the responsive temperature o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473767/ https://www.ncbi.nlm.nih.gov/pubmed/34562737 http://dx.doi.org/10.1016/j.ultsonch.2021.105752 |
_version_ | 1784575064852660224 |
---|---|
author | Kubo, Masaki Higuchi, Masato Koshimura, Tomoyuki Shoji, Eita Tsukada, Takao |
author_facet | Kubo, Masaki Higuchi, Masato Koshimura, Tomoyuki Shoji, Eita Tsukada, Takao |
author_sort | Kubo, Masaki |
collection | PubMed |
description | Poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) (poly(NIPAM-co-HEMA)) is a temperature-responsive copolymer that is expected to be applicable as an advanced functional polymeric material in various fields. In this study, a novel method was developed to control the responsive temperature of poly(NIPAM-co-HEMA) using an ultrasonic polymerization technique. Initially, the behavior of the reaction was investigated using NIPAM and HEMA monomers under ultrasonic irradiation. A high ultrasonic power was found to produce a high reaction rate and low number average molecular weight of the copolymer. The polydispersity of the synthesized copolymer was approximately 1.5 for all ultrasonic powers examined. In the early stage of the reaction, the molar fraction of NIPAM in the copolymer was lower than the initial molar fraction of the monomers. It was concluded that ultrasonic irradiation affected the initiation reaction and polymer degradation, but did not affect the propagation reaction. Furthermore, the effect of the ultrasonic irradiation conditions on the temperature responsiveness of the copolymer was investigated. The lower critical solution temperature (LCST) of the copolymer was found to increase with increasing ultrasonic irradiation time. In addition, in the early stages of the reaction, the measured values of the LCST were higher than the estimated values using copolymer composition. This can be attributed to some parts of the copolymer chain possessing a higher NIPAM fraction than the overall fraction due to different reactivities of the monomers and terminated radicals. This hypothesis was indirectly verified by the synthesis of a block copolymer from the PNIPAM homopolymer and HEMA monomer. |
format | Online Article Text |
id | pubmed-8473767 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-84737672021-10-01 Control of the temperature responsiveness of poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) copolymer using ultrasonic irradiation Kubo, Masaki Higuchi, Masato Koshimura, Tomoyuki Shoji, Eita Tsukada, Takao Ultrason Sonochem Original Research Article Poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) (poly(NIPAM-co-HEMA)) is a temperature-responsive copolymer that is expected to be applicable as an advanced functional polymeric material in various fields. In this study, a novel method was developed to control the responsive temperature of poly(NIPAM-co-HEMA) using an ultrasonic polymerization technique. Initially, the behavior of the reaction was investigated using NIPAM and HEMA monomers under ultrasonic irradiation. A high ultrasonic power was found to produce a high reaction rate and low number average molecular weight of the copolymer. The polydispersity of the synthesized copolymer was approximately 1.5 for all ultrasonic powers examined. In the early stage of the reaction, the molar fraction of NIPAM in the copolymer was lower than the initial molar fraction of the monomers. It was concluded that ultrasonic irradiation affected the initiation reaction and polymer degradation, but did not affect the propagation reaction. Furthermore, the effect of the ultrasonic irradiation conditions on the temperature responsiveness of the copolymer was investigated. The lower critical solution temperature (LCST) of the copolymer was found to increase with increasing ultrasonic irradiation time. In addition, in the early stages of the reaction, the measured values of the LCST were higher than the estimated values using copolymer composition. This can be attributed to some parts of the copolymer chain possessing a higher NIPAM fraction than the overall fraction due to different reactivities of the monomers and terminated radicals. This hypothesis was indirectly verified by the synthesis of a block copolymer from the PNIPAM homopolymer and HEMA monomer. Elsevier 2021-09-13 /pmc/articles/PMC8473767/ /pubmed/34562737 http://dx.doi.org/10.1016/j.ultsonch.2021.105752 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Kubo, Masaki Higuchi, Masato Koshimura, Tomoyuki Shoji, Eita Tsukada, Takao Control of the temperature responsiveness of poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) copolymer using ultrasonic irradiation |
title | Control of the temperature responsiveness of poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) copolymer using ultrasonic irradiation |
title_full | Control of the temperature responsiveness of poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) copolymer using ultrasonic irradiation |
title_fullStr | Control of the temperature responsiveness of poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) copolymer using ultrasonic irradiation |
title_full_unstemmed | Control of the temperature responsiveness of poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) copolymer using ultrasonic irradiation |
title_short | Control of the temperature responsiveness of poly(N-isopropylacrylamide-co-2-hydroxyethyl methacrylate) copolymer using ultrasonic irradiation |
title_sort | control of the temperature responsiveness of poly(n-isopropylacrylamide-co-2-hydroxyethyl methacrylate) copolymer using ultrasonic irradiation |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473767/ https://www.ncbi.nlm.nih.gov/pubmed/34562737 http://dx.doi.org/10.1016/j.ultsonch.2021.105752 |
work_keys_str_mv | AT kubomasaki controlofthetemperatureresponsivenessofpolynisopropylacrylamideco2hydroxyethylmethacrylatecopolymerusingultrasonicirradiation AT higuchimasato controlofthetemperatureresponsivenessofpolynisopropylacrylamideco2hydroxyethylmethacrylatecopolymerusingultrasonicirradiation AT koshimuratomoyuki controlofthetemperatureresponsivenessofpolynisopropylacrylamideco2hydroxyethylmethacrylatecopolymerusingultrasonicirradiation AT shojieita controlofthetemperatureresponsivenessofpolynisopropylacrylamideco2hydroxyethylmethacrylatecopolymerusingultrasonicirradiation AT tsukadatakao controlofthetemperatureresponsivenessofpolynisopropylacrylamideco2hydroxyethylmethacrylatecopolymerusingultrasonicirradiation |