Cargando…
Evaluating differences in respiratory motion estimates during radiotherapy: a single planning 4DMRI versus daily 4DMRI
BACKGROUND: In radiotherapy, respiratory-induced tumor motion is typically measured using a single four-dimensional computed tomography acquisition (4DCT). Irregular breathing leads to inaccurate motion estimates, potentially resulting in undertreatment of the tumor and unnecessary dose to healthy t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8474826/ https://www.ncbi.nlm.nih.gov/pubmed/34565384 http://dx.doi.org/10.1186/s13014-021-01915-1 |
_version_ | 1784575306049257472 |
---|---|
author | den Boer, Duncan Veldman, Johannes K. van Tienhoven, Geertjan Bel, Arjan van Kesteren, Zdenko |
author_facet | den Boer, Duncan Veldman, Johannes K. van Tienhoven, Geertjan Bel, Arjan van Kesteren, Zdenko |
author_sort | den Boer, Duncan |
collection | PubMed |
description | BACKGROUND: In radiotherapy, respiratory-induced tumor motion is typically measured using a single four-dimensional computed tomography acquisition (4DCT). Irregular breathing leads to inaccurate motion estimates, potentially resulting in undertreatment of the tumor and unnecessary dose to healthy tissue. The aim of the research was to determine if a daily pre-treatment 4DMRI-strategy led to a significantly improved motion estimate compared to single planning 4DMRI (with or without outlier rejection). METHODS: 4DMRI data sets from 10 healthy volunteers were acquired. The first acquisition simulated a planning MRI, the respiratory motion estimate (constructed from the respiratory signal, i.e. the 1D navigator) was compared to the respiratory signal in the subsequent scans (simulating 5–29 treatment fractions). The same procedure was performed using the first acquisition of each day as an estimate for the subsequent acquisitions that day (2 per day, 4–20 per volunteer), simulating a daily MRI strategy. This was done for three outlier strategies: no outlier rejection (NoOR); excluding 5% of the respiratory signal whilst minimizing the range (Min95) and excluding the datapoints outside the mean end-inhalation and end-exhalation positions (MeanIE). RESULTS: The planning MRI median motion estimates were 27 mm for NoOR, 18 mm for Min95, and 13 mm for MeanIE. The daily MRI median motion estimates were 29 mm for NoOR, 19 mm for Min95 and 15 mm for MeanIE. The percentage of time outside the motion estimate were for the planning MRI: 2%, 10% and 32% for NoOR, Min95 and MeanIE respectively. These values were reduced with the daily MRI strategy: 0%, 6% and 17%. Applying Min95 accounted for a 30% decrease in motion estimate compared to NoOR. CONCLUSION: A daily MRI improved the estimation of respiratory motion as compared to a single 4D (planning) MRI significantly. Combining the Min95 technique with a daily 4DMRI resulted in a decrease of inclusion time of 6% with a 30% decrease of motion. Outlier rejection alone on a planning MRI often led to underestimation of the movement and could potentially lead to an underdosage. Trial registration: protocol W15_373#16.007 SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-021-01915-1. |
format | Online Article Text |
id | pubmed-8474826 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-84748262021-09-28 Evaluating differences in respiratory motion estimates during radiotherapy: a single planning 4DMRI versus daily 4DMRI den Boer, Duncan Veldman, Johannes K. van Tienhoven, Geertjan Bel, Arjan van Kesteren, Zdenko Radiat Oncol Research BACKGROUND: In radiotherapy, respiratory-induced tumor motion is typically measured using a single four-dimensional computed tomography acquisition (4DCT). Irregular breathing leads to inaccurate motion estimates, potentially resulting in undertreatment of the tumor and unnecessary dose to healthy tissue. The aim of the research was to determine if a daily pre-treatment 4DMRI-strategy led to a significantly improved motion estimate compared to single planning 4DMRI (with or without outlier rejection). METHODS: 4DMRI data sets from 10 healthy volunteers were acquired. The first acquisition simulated a planning MRI, the respiratory motion estimate (constructed from the respiratory signal, i.e. the 1D navigator) was compared to the respiratory signal in the subsequent scans (simulating 5–29 treatment fractions). The same procedure was performed using the first acquisition of each day as an estimate for the subsequent acquisitions that day (2 per day, 4–20 per volunteer), simulating a daily MRI strategy. This was done for three outlier strategies: no outlier rejection (NoOR); excluding 5% of the respiratory signal whilst minimizing the range (Min95) and excluding the datapoints outside the mean end-inhalation and end-exhalation positions (MeanIE). RESULTS: The planning MRI median motion estimates were 27 mm for NoOR, 18 mm for Min95, and 13 mm for MeanIE. The daily MRI median motion estimates were 29 mm for NoOR, 19 mm for Min95 and 15 mm for MeanIE. The percentage of time outside the motion estimate were for the planning MRI: 2%, 10% and 32% for NoOR, Min95 and MeanIE respectively. These values were reduced with the daily MRI strategy: 0%, 6% and 17%. Applying Min95 accounted for a 30% decrease in motion estimate compared to NoOR. CONCLUSION: A daily MRI improved the estimation of respiratory motion as compared to a single 4D (planning) MRI significantly. Combining the Min95 technique with a daily 4DMRI resulted in a decrease of inclusion time of 6% with a 30% decrease of motion. Outlier rejection alone on a planning MRI often led to underestimation of the movement and could potentially lead to an underdosage. Trial registration: protocol W15_373#16.007 SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-021-01915-1. BioMed Central 2021-09-26 /pmc/articles/PMC8474826/ /pubmed/34565384 http://dx.doi.org/10.1186/s13014-021-01915-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research den Boer, Duncan Veldman, Johannes K. van Tienhoven, Geertjan Bel, Arjan van Kesteren, Zdenko Evaluating differences in respiratory motion estimates during radiotherapy: a single planning 4DMRI versus daily 4DMRI |
title | Evaluating differences in respiratory motion estimates during radiotherapy: a single planning 4DMRI versus daily 4DMRI |
title_full | Evaluating differences in respiratory motion estimates during radiotherapy: a single planning 4DMRI versus daily 4DMRI |
title_fullStr | Evaluating differences in respiratory motion estimates during radiotherapy: a single planning 4DMRI versus daily 4DMRI |
title_full_unstemmed | Evaluating differences in respiratory motion estimates during radiotherapy: a single planning 4DMRI versus daily 4DMRI |
title_short | Evaluating differences in respiratory motion estimates during radiotherapy: a single planning 4DMRI versus daily 4DMRI |
title_sort | evaluating differences in respiratory motion estimates during radiotherapy: a single planning 4dmri versus daily 4dmri |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8474826/ https://www.ncbi.nlm.nih.gov/pubmed/34565384 http://dx.doi.org/10.1186/s13014-021-01915-1 |
work_keys_str_mv | AT denboerduncan evaluatingdifferencesinrespiratorymotionestimatesduringradiotherapyasingleplanning4dmriversusdaily4dmri AT veldmanjohannesk evaluatingdifferencesinrespiratorymotionestimatesduringradiotherapyasingleplanning4dmriversusdaily4dmri AT vantienhovengeertjan evaluatingdifferencesinrespiratorymotionestimatesduringradiotherapyasingleplanning4dmriversusdaily4dmri AT belarjan evaluatingdifferencesinrespiratorymotionestimatesduringradiotherapyasingleplanning4dmriversusdaily4dmri AT vankesterenzdenko evaluatingdifferencesinrespiratorymotionestimatesduringradiotherapyasingleplanning4dmriversusdaily4dmri |