Cargando…
Comparison of conventional and wide field direct ophthalmoscopy on medical students’ self-confidence for fundus examination: a 1-year follow-up
BACKGROUND: Fundus examination is an easy, quick and effective way to diagnose sight- and life-threatening diseases. However, medical students and physicians report lack of proficiency and self-confidence in perform fundoscopy. The aim of this study was to compare students’ self-confidence in fundus...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8474948/ https://www.ncbi.nlm.nih.gov/pubmed/34565378 http://dx.doi.org/10.1186/s12909-021-02942-y |
_version_ | 1784575336989589504 |
---|---|
author | Ayub, Gabriel Souza, Rafael Boava de Albuquerque, Andrelisa Marina de Vasconcellos, José Paulo Cabral |
author_facet | Ayub, Gabriel Souza, Rafael Boava de Albuquerque, Andrelisa Marina de Vasconcellos, José Paulo Cabral |
author_sort | Ayub, Gabriel |
collection | PubMed |
description | BACKGROUND: Fundus examination is an easy, quick and effective way to diagnose sight- and life-threatening diseases. However, medical students and physicians report lack of proficiency and self-confidence in perform fundoscopy. The aim of this study was to compare students’ self-confidence in fundus examination, using two different direct ophthalmoscopes, 1 month and 1 year after practical training. METHODS: In this prospective cohort, medical students (MS) of the same class were divided in small groups for PanOptic (PO) or conventional (CO) direct ophthalmoscope training. The intervention group encompassed MS of the 4th -year (class of 2019), and the control group encompassed MS of year behind (class of 2020). A questionnaire to measure self-confidence in fundoscopy technique assessing optic nerve, cup-to-disc ratio and macula was translated and validated to Portuguese, and applied 1-month and 1-year after practical training. RESULTS: One-hundred and sixty-seven MS were enrolled (35 PO group, 38 CO group, and 94 control group). PO group had a significantly higher overall self-confidence comparing either control or CO groups, respectively (3.57 ± 0.65 vs. 2.97 ± 1.03 vs. 2.46 ± 0.87, p < 0.01) as well as in evaluate cup-to-disc ratio (3.09 ± 0.75 vs. 2.32 ± 0.87 vs. 1.46 ± 0.81, p < 0.01), optic disc margins (3.26 ± 0.85 vs. 2.71 ± 0.96 vs. 2.01 ± 0.97, p < 0.01) and macula (3.43 ± 1.12 vs. 2.89 ± 1.08 vs. 2.02 ± 0.89, p < 0.01) 1-month after practical training. One-year after intervention, CO group showed a significantly higher score compared to PO group in overall self-confidence (3.31 ± 0.69 vs. 3.18 ± 0.73, p = 0.03) and in optic disc margins assessing (3.16 ± 0.85 vs. 2.95 ± 0.78, p = 0.03), but not significant in the evaluation of cup-to-disc ratio (2.78 ± 0.97 vs. 2.68 ± 0.94, p = 0.08), and macula (3.34 ± 0.79 vs. 3.27 ± 0.98, p = 0.07). CONCLUSIONS: Students were more confident in use PO as an instrument to perform direct ophthalmoscopy immediately after practical training, but confidence level of CO was higher compared to PO one year after practical training. These findings would help medical schools decide which ophthalmoscope to choose to teach fundus examination. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12909-021-02942-y. |
format | Online Article Text |
id | pubmed-8474948 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-84749482021-09-28 Comparison of conventional and wide field direct ophthalmoscopy on medical students’ self-confidence for fundus examination: a 1-year follow-up Ayub, Gabriel Souza, Rafael Boava de Albuquerque, Andrelisa Marina de Vasconcellos, José Paulo Cabral BMC Med Educ Research Article BACKGROUND: Fundus examination is an easy, quick and effective way to diagnose sight- and life-threatening diseases. However, medical students and physicians report lack of proficiency and self-confidence in perform fundoscopy. The aim of this study was to compare students’ self-confidence in fundus examination, using two different direct ophthalmoscopes, 1 month and 1 year after practical training. METHODS: In this prospective cohort, medical students (MS) of the same class were divided in small groups for PanOptic (PO) or conventional (CO) direct ophthalmoscope training. The intervention group encompassed MS of the 4th -year (class of 2019), and the control group encompassed MS of year behind (class of 2020). A questionnaire to measure self-confidence in fundoscopy technique assessing optic nerve, cup-to-disc ratio and macula was translated and validated to Portuguese, and applied 1-month and 1-year after practical training. RESULTS: One-hundred and sixty-seven MS were enrolled (35 PO group, 38 CO group, and 94 control group). PO group had a significantly higher overall self-confidence comparing either control or CO groups, respectively (3.57 ± 0.65 vs. 2.97 ± 1.03 vs. 2.46 ± 0.87, p < 0.01) as well as in evaluate cup-to-disc ratio (3.09 ± 0.75 vs. 2.32 ± 0.87 vs. 1.46 ± 0.81, p < 0.01), optic disc margins (3.26 ± 0.85 vs. 2.71 ± 0.96 vs. 2.01 ± 0.97, p < 0.01) and macula (3.43 ± 1.12 vs. 2.89 ± 1.08 vs. 2.02 ± 0.89, p < 0.01) 1-month after practical training. One-year after intervention, CO group showed a significantly higher score compared to PO group in overall self-confidence (3.31 ± 0.69 vs. 3.18 ± 0.73, p = 0.03) and in optic disc margins assessing (3.16 ± 0.85 vs. 2.95 ± 0.78, p = 0.03), but not significant in the evaluation of cup-to-disc ratio (2.78 ± 0.97 vs. 2.68 ± 0.94, p = 0.08), and macula (3.34 ± 0.79 vs. 3.27 ± 0.98, p = 0.07). CONCLUSIONS: Students were more confident in use PO as an instrument to perform direct ophthalmoscopy immediately after practical training, but confidence level of CO was higher compared to PO one year after practical training. These findings would help medical schools decide which ophthalmoscope to choose to teach fundus examination. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12909-021-02942-y. BioMed Central 2021-09-26 /pmc/articles/PMC8474948/ /pubmed/34565378 http://dx.doi.org/10.1186/s12909-021-02942-y Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Ayub, Gabriel Souza, Rafael Boava de Albuquerque, Andrelisa Marina de Vasconcellos, José Paulo Cabral Comparison of conventional and wide field direct ophthalmoscopy on medical students’ self-confidence for fundus examination: a 1-year follow-up |
title | Comparison of conventional and wide field direct ophthalmoscopy on medical students’ self-confidence for fundus examination: a 1-year follow-up |
title_full | Comparison of conventional and wide field direct ophthalmoscopy on medical students’ self-confidence for fundus examination: a 1-year follow-up |
title_fullStr | Comparison of conventional and wide field direct ophthalmoscopy on medical students’ self-confidence for fundus examination: a 1-year follow-up |
title_full_unstemmed | Comparison of conventional and wide field direct ophthalmoscopy on medical students’ self-confidence for fundus examination: a 1-year follow-up |
title_short | Comparison of conventional and wide field direct ophthalmoscopy on medical students’ self-confidence for fundus examination: a 1-year follow-up |
title_sort | comparison of conventional and wide field direct ophthalmoscopy on medical students’ self-confidence for fundus examination: a 1-year follow-up |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8474948/ https://www.ncbi.nlm.nih.gov/pubmed/34565378 http://dx.doi.org/10.1186/s12909-021-02942-y |
work_keys_str_mv | AT ayubgabriel comparisonofconventionalandwidefielddirectophthalmoscopyonmedicalstudentsselfconfidenceforfundusexaminationa1yearfollowup AT souzarafaelboava comparisonofconventionalandwidefielddirectophthalmoscopyonmedicalstudentsselfconfidenceforfundusexaminationa1yearfollowup AT dealbuquerqueandrelisamarina comparisonofconventionalandwidefielddirectophthalmoscopyonmedicalstudentsselfconfidenceforfundusexaminationa1yearfollowup AT devasconcellosjosepaulocabral comparisonofconventionalandwidefielddirectophthalmoscopyonmedicalstudentsselfconfidenceforfundusexaminationa1yearfollowup |