Cargando…
VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype
The COVID-19 pandemic has caused personal protective equipment shortages worldwide and required healthcare workers to develop novel ways of protecting themselves. Anesthesiologists in particular are exposed to increased risks of contamination when performing interventions such as airway manipulation...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8475855/ https://www.ncbi.nlm.nih.gov/pubmed/34562184 http://dx.doi.org/10.1007/s10877-021-00759-0 |
_version_ | 1784575486857314304 |
---|---|
author | Issa, Rami Urbanowicz, Robert Richebé, Philippe Blain, Julie Ferreira Benevides, Alexandre Tanoubi, Issam |
author_facet | Issa, Rami Urbanowicz, Robert Richebé, Philippe Blain, Julie Ferreira Benevides, Alexandre Tanoubi, Issam |
author_sort | Issa, Rami |
collection | PubMed |
description | The COVID-19 pandemic has caused personal protective equipment shortages worldwide and required healthcare workers to develop novel ways of protecting themselves. Anesthesiologists in particular are exposed to increased risks of contamination when performing interventions such as airway manipulations. We developed and tested an aerosolization protective device which contains aerosols around the patient’s airway and helps eliminate particles using negative pressure. This intubation box is a polymethyl methacrylate prism with openings for gloves, integrated suction and ventilation connectors. We conducted a randomised controlled series of tests to detect 0.5 µm particles after a simulated cough inside the intubation box, using a high-fidelity simulation mannequin. Setting and main outcome: We measured particle concentrations inside the box with and without suction turned on, in both negative and positive pressure operating rooms. We also obtained particle concentrations outside our box and compared them to non-airtight barrier devices. One minute following simulated cough, the mean number of particles per cubic foot in our box with suction on is around 45% that with the suction off (1,462,373 vs 3,272,080, P < 0.0001) in the negative pressure room, and four times lower than with the suction off (760,380 vs 3,088,700, P < 0.0001) in the positive pressure room. After a simulated cough inside the box, particles can be detected in front of the anesthesiologist’s face with a non-airtight device, while none are detected when our box is sealed and its suction turned on. The use of our negative pressure intubation box prevents contamination of surroundings and increases particle elimination, regardless of room pressure. |
format | Online Article Text |
id | pubmed-8475855 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-84758552021-09-28 VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype Issa, Rami Urbanowicz, Robert Richebé, Philippe Blain, Julie Ferreira Benevides, Alexandre Tanoubi, Issam J Clin Monit Comput Original Research The COVID-19 pandemic has caused personal protective equipment shortages worldwide and required healthcare workers to develop novel ways of protecting themselves. Anesthesiologists in particular are exposed to increased risks of contamination when performing interventions such as airway manipulations. We developed and tested an aerosolization protective device which contains aerosols around the patient’s airway and helps eliminate particles using negative pressure. This intubation box is a polymethyl methacrylate prism with openings for gloves, integrated suction and ventilation connectors. We conducted a randomised controlled series of tests to detect 0.5 µm particles after a simulated cough inside the intubation box, using a high-fidelity simulation mannequin. Setting and main outcome: We measured particle concentrations inside the box with and without suction turned on, in both negative and positive pressure operating rooms. We also obtained particle concentrations outside our box and compared them to non-airtight barrier devices. One minute following simulated cough, the mean number of particles per cubic foot in our box with suction on is around 45% that with the suction off (1,462,373 vs 3,272,080, P < 0.0001) in the negative pressure room, and four times lower than with the suction off (760,380 vs 3,088,700, P < 0.0001) in the positive pressure room. After a simulated cough inside the box, particles can be detected in front of the anesthesiologist’s face with a non-airtight device, while none are detected when our box is sealed and its suction turned on. The use of our negative pressure intubation box prevents contamination of surroundings and increases particle elimination, regardless of room pressure. Springer Netherlands 2021-09-25 2022 /pmc/articles/PMC8475855/ /pubmed/34562184 http://dx.doi.org/10.1007/s10877-021-00759-0 Text en © The Author(s), under exclusive licence to Springer Nature B.V. 2021 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Original Research Issa, Rami Urbanowicz, Robert Richebé, Philippe Blain, Julie Ferreira Benevides, Alexandre Tanoubi, Issam VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype |
title | VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype |
title_full | VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype |
title_fullStr | VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype |
title_full_unstemmed | VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype |
title_short | VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype |
title_sort | vacuum intubation (vaccin) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8475855/ https://www.ncbi.nlm.nih.gov/pubmed/34562184 http://dx.doi.org/10.1007/s10877-021-00759-0 |
work_keys_str_mv | AT issarami vacuumintubationvaccinboxrestrictstheexhaledairdispersiongeneratedbysimulatedcoughdescriptionandsimulationbasedtestsofaninnovativeaerosolizationprotectiveprototype AT urbanowiczrobert vacuumintubationvaccinboxrestrictstheexhaledairdispersiongeneratedbysimulatedcoughdescriptionandsimulationbasedtestsofaninnovativeaerosolizationprotectiveprototype AT richebephilippe vacuumintubationvaccinboxrestrictstheexhaledairdispersiongeneratedbysimulatedcoughdescriptionandsimulationbasedtestsofaninnovativeaerosolizationprotectiveprototype AT blainjulie vacuumintubationvaccinboxrestrictstheexhaledairdispersiongeneratedbysimulatedcoughdescriptionandsimulationbasedtestsofaninnovativeaerosolizationprotectiveprototype AT ferreirabenevidesalexandre vacuumintubationvaccinboxrestrictstheexhaledairdispersiongeneratedbysimulatedcoughdescriptionandsimulationbasedtestsofaninnovativeaerosolizationprotectiveprototype AT tanoubiissam vacuumintubationvaccinboxrestrictstheexhaledairdispersiongeneratedbysimulatedcoughdescriptionandsimulationbasedtestsofaninnovativeaerosolizationprotectiveprototype |