OBJECTIVES: The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures (PROMs) compared to conventional impression (CI) techniques, taking into account the size of the scanned area. The secon...

Descripción completa

Detalles Bibliográficos
Autores principales: Siqueira, Rafael, Galli, Matthew, Chen, Zhaozhao, Mendonça, Gustavo, Meirelles, Luiz, Wang, Hom-Lay, Chan, Hsun-Liang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8475874/
https://www.ncbi.nlm.nih.gov/pubmed/34568955
http://dx.doi.org/10.1007/s00784-021-04157-3
_version_ 1784575490103705600
author Siqueira, Rafael
Galli, Matthew
Chen, Zhaozhao
Mendonça, Gustavo
Meirelles, Luiz
Wang, Hom-Lay
Chan, Hsun-Liang
author_facet Siqueira, Rafael
Galli, Matthew
Chen, Zhaozhao
Mendonça, Gustavo
Meirelles, Luiz
Wang, Hom-Lay
Chan, Hsun-Liang
author_sort Siqueira, Rafael
collection PubMed
description OBJECTIVES: The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures (PROMs) compared to conventional impression (CI) techniques, taking into account the size of the scanned area. The secondary aim was to verify the effectiveness of IOS procedures based on available prosthodontic outcomes. MATERIALS AND METHODS: Electronic and manual literature searches were performed to collect evidence concerning the outcomes of IOS and CI performed during the treatment of partially and complete edentulous patients for tooth- or implant-supported restorations. Qualitative analysis was conducted to evaluate the time efficiency and PROMs produced by the two different techniques. Clinical prosthodontic outcomes were analyzed among the included studies when available. RESULTS: Seventeen studies (9 randomized controlled trials and 8 prospective clinical studies) were selected for qualitative synthesis. The 17 included studies provided data from 430 IOS and 370 CI performed in 437 patients. A total of 7 different IOS systems and their various updated versions were used for digital impressions. The results demonstrated that IOS was overall faster than CI independent of whether quadrant or complete-arch scanning was utilized, regardless of the nature of the restoration (tooth or implant supported). IOS was generally preferred over CI regardless of the size of the scanned area and nature of the restoration (tooth- or implant-supported). Similar prosthodontic outcomes were reported for workflows implementing CI and IOS. CONCLUSIONS: Within the limitations of this systematic review, IOS is faster than CI, independent of whether a quadrant or complete arch scan is conducted. IOS can improve the patient experience measured by overall preference and comfort and is able to provide reliable prosthodontic outcomes. CLINICAL RELEVANCE: Reduced procedure working time associated with the use of IOS can improve clinical efficiency and the patient experience during impression procedures. Patient-reported outcome measures (PROMs) are an essential component of evidence-based dental practice as they allow the evaluation of therapeutic modalities from the perspective of the patient. IOS is generally preferred by patients over conventional impressions. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00784-021-04157-3.
format Online
Article
Text
id pubmed-8475874
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-84758742021-09-28 Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review Siqueira, Rafael Galli, Matthew Chen, Zhaozhao Mendonça, Gustavo Meirelles, Luiz Wang, Hom-Lay Chan, Hsun-Liang Clin Oral Investig Review OBJECTIVES: The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures (PROMs) compared to conventional impression (CI) techniques, taking into account the size of the scanned area. The secondary aim was to verify the effectiveness of IOS procedures based on available prosthodontic outcomes. MATERIALS AND METHODS: Electronic and manual literature searches were performed to collect evidence concerning the outcomes of IOS and CI performed during the treatment of partially and complete edentulous patients for tooth- or implant-supported restorations. Qualitative analysis was conducted to evaluate the time efficiency and PROMs produced by the two different techniques. Clinical prosthodontic outcomes were analyzed among the included studies when available. RESULTS: Seventeen studies (9 randomized controlled trials and 8 prospective clinical studies) were selected for qualitative synthesis. The 17 included studies provided data from 430 IOS and 370 CI performed in 437 patients. A total of 7 different IOS systems and their various updated versions were used for digital impressions. The results demonstrated that IOS was overall faster than CI independent of whether quadrant or complete-arch scanning was utilized, regardless of the nature of the restoration (tooth or implant supported). IOS was generally preferred over CI regardless of the size of the scanned area and nature of the restoration (tooth- or implant-supported). Similar prosthodontic outcomes were reported for workflows implementing CI and IOS. CONCLUSIONS: Within the limitations of this systematic review, IOS is faster than CI, independent of whether a quadrant or complete arch scan is conducted. IOS can improve the patient experience measured by overall preference and comfort and is able to provide reliable prosthodontic outcomes. CLINICAL RELEVANCE: Reduced procedure working time associated with the use of IOS can improve clinical efficiency and the patient experience during impression procedures. Patient-reported outcome measures (PROMs) are an essential component of evidence-based dental practice as they allow the evaluation of therapeutic modalities from the perspective of the patient. IOS is generally preferred by patients over conventional impressions. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00784-021-04157-3. Springer Berlin Heidelberg 2021-09-27 2021 /pmc/articles/PMC8475874/ /pubmed/34568955 http://dx.doi.org/10.1007/s00784-021-04157-3 Text en © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2021 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Review
Siqueira, Rafael
Galli, Matthew
Chen, Zhaozhao
Mendonça, Gustavo
Meirelles, Luiz
Wang, Hom-Lay
Chan, Hsun-Liang
Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review
title Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review
title_full Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review
title_fullStr Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review
title_full_unstemmed Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review
title_short Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review
title_sort intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8475874/
https://www.ncbi.nlm.nih.gov/pubmed/34568955
http://dx.doi.org/10.1007/s00784-021-04157-3
work_keys_str_mv AT siqueirarafael intraoralscanningreducesproceduretimeandimprovespatientcomfortinfixedprosthodonticsandimplantdentistryasystematicreview
AT gallimatthew intraoralscanningreducesproceduretimeandimprovespatientcomfortinfixedprosthodonticsandimplantdentistryasystematicreview
AT chenzhaozhao intraoralscanningreducesproceduretimeandimprovespatientcomfortinfixedprosthodonticsandimplantdentistryasystematicreview
AT mendoncagustavo intraoralscanningreducesproceduretimeandimprovespatientcomfortinfixedprosthodonticsandimplantdentistryasystematicreview
AT meirellesluiz intraoralscanningreducesproceduretimeandimprovespatientcomfortinfixedprosthodonticsandimplantdentistryasystematicreview
AT wanghomlay intraoralscanningreducesproceduretimeandimprovespatientcomfortinfixedprosthodonticsandimplantdentistryasystematicreview
AT chanhsunliang intraoralscanningreducesproceduretimeandimprovespatientcomfortinfixedprosthodonticsandimplantdentistryasystematicreview