Early Experience with High-density Electroanatomical Mapping Using the Rhythmia™ Mapping System in Congenital and Pediatric Heart Disease

The Rhythmia™ system (Boston Scientific, Natick, MA, USA) facilitates the rapid acquisition of high-resolution electroanatomical and activation maps. However, there are limited data on its efficacy and safety in pediatric and adult congenital heart disease (CHD) patients. In a retrospective, observa...

Descripción completa

Detalles Bibliográficos
Autores principales: Saef, Joshua M., Burke, Brendan J., Tchou, Patrick J., Aziz, Peter F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MediaSphere Medical 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8476094/
https://www.ncbi.nlm.nih.gov/pubmed/34595049
http://dx.doi.org/10.19102/icrm.2021.120901
Descripción
Sumario:The Rhythmia™ system (Boston Scientific, Natick, MA, USA) facilitates the rapid acquisition of high-resolution electroanatomical and activation maps. However, there are limited data on its efficacy and safety in pediatric and adult congenital heart disease (CHD) patients. In a retrospective, observational cohort study, adult CHD and pediatric patients followed by pediatric cardiology underwent electrophysiologic study using the Rhythmia™ electroanatomic mapping system. Variables examined included the number of electroanatomical maps required, acquisition time, procedure time, fluoroscopy time, radiation dosage, and rate of recurrent arrhythmia. Twelve consecutive patients, including six male patients (50%), were included with an average age of 27.7 years (range: 11–64 years). Seven (58%) of these patients had a diagnosis of CHD [moderate complexity in two (17%) and great complexity in five patients (42%)] and 10 (83%) patients underwent ablation. A total of 37 high-density maps were created in 12 procedures, with a median of 8,140 mapping points, taking a median of 631 seconds. The median procedure time was 189.5 minutes. The median fluoroscopy time was 0.9 minutes, with eight (67%) patients receiving no fluoroscopy at all. Recurrence occurred in one patient (8%) over a median follow-up duration of 16 months (interquartile range: 12.8–17.3 months). No adverse periprocedural events were recorded. This study suggests the use of high-density electroanatomic mapping in adult CHD patients showed potential for rapid acquisition of highly detailed maps with minimal fluoroscopy time or risk of periprocedural events in the studied population.