Cargando…
Differentiation of uterine low-grade endometrial stromal sarcoma from rare leiomyoma variants by magnetic resonance imaging
The purpose of this study is to evaluate utility of MRI in differentiation of uterine low-grade endometrial stromal sarcoma (LGESS) from rare leiomyoma variants. This multi-center retrospective study included consecutive 25 patients with uterine LGESS and 42 patients with rare leiomyoma variants who...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8476551/ https://www.ncbi.nlm.nih.gov/pubmed/34580348 http://dx.doi.org/10.1038/s41598-021-98473-z |
_version_ | 1784575641484525568 |
---|---|
author | Himoto, Yuki Kido, Aki Sakata, Akihiko Moribata, Yusaku Kurata, Yasuhisa Suzuki, Ayako Matsumura, Noriomi Shitano, Fuki Kawahara, Seiya Kubo, Shigeto Umeoka, Shigeaki Minamiguchi, Sachiko Mandai, Masaki |
author_facet | Himoto, Yuki Kido, Aki Sakata, Akihiko Moribata, Yusaku Kurata, Yasuhisa Suzuki, Ayako Matsumura, Noriomi Shitano, Fuki Kawahara, Seiya Kubo, Shigeto Umeoka, Shigeaki Minamiguchi, Sachiko Mandai, Masaki |
author_sort | Himoto, Yuki |
collection | PubMed |
description | The purpose of this study is to evaluate utility of MRI in differentiation of uterine low-grade endometrial stromal sarcoma (LGESS) from rare leiomyoma variants. This multi-center retrospective study included consecutive 25 patients with uterine LGESS and 42 patients with rare leiomyoma variants who had pretreatment MRI. Two radiologists (R1/R2) independently evaluated MRI features, which were analyzed statistically using Fisher’s exact test or Student's t-test. Subsequently, using a five-point Likert scale, the two radiologists evaluated the diagnostic performance of a pre-defined MRI system using features reported as characteristics of LGESS in previous case series: uterine tumor with high signal intensity (SI) on diffusion-weighted images and with either worm-like nodular extension, intra-tumoral low SI bands, or low SI rim on T2-weighted images. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of the two readers’ Likert scales were analyzed. Intra-tumoral low SI bands (p < 0.001), cystic/necrotic change (p ≤ 0.02), absence of speckled appearance (p < 0.001) on T2-weighted images, and a low apparent diffusion coefficient value (p ≤ 0.02) were significantly associated with LGESS. The pre-defined MRI system showed very good diagnostic performance: AUC 0.86/0.89, sensitivity 0.95/0.95, and specificity 0.67/0.69 for R1/R2. MRI can be useful to differentiate uterine LGESS from rare leiomyoma variants. |
format | Online Article Text |
id | pubmed-8476551 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-84765512021-09-29 Differentiation of uterine low-grade endometrial stromal sarcoma from rare leiomyoma variants by magnetic resonance imaging Himoto, Yuki Kido, Aki Sakata, Akihiko Moribata, Yusaku Kurata, Yasuhisa Suzuki, Ayako Matsumura, Noriomi Shitano, Fuki Kawahara, Seiya Kubo, Shigeto Umeoka, Shigeaki Minamiguchi, Sachiko Mandai, Masaki Sci Rep Article The purpose of this study is to evaluate utility of MRI in differentiation of uterine low-grade endometrial stromal sarcoma (LGESS) from rare leiomyoma variants. This multi-center retrospective study included consecutive 25 patients with uterine LGESS and 42 patients with rare leiomyoma variants who had pretreatment MRI. Two radiologists (R1/R2) independently evaluated MRI features, which were analyzed statistically using Fisher’s exact test or Student's t-test. Subsequently, using a five-point Likert scale, the two radiologists evaluated the diagnostic performance of a pre-defined MRI system using features reported as characteristics of LGESS in previous case series: uterine tumor with high signal intensity (SI) on diffusion-weighted images and with either worm-like nodular extension, intra-tumoral low SI bands, or low SI rim on T2-weighted images. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of the two readers’ Likert scales were analyzed. Intra-tumoral low SI bands (p < 0.001), cystic/necrotic change (p ≤ 0.02), absence of speckled appearance (p < 0.001) on T2-weighted images, and a low apparent diffusion coefficient value (p ≤ 0.02) were significantly associated with LGESS. The pre-defined MRI system showed very good diagnostic performance: AUC 0.86/0.89, sensitivity 0.95/0.95, and specificity 0.67/0.69 for R1/R2. MRI can be useful to differentiate uterine LGESS from rare leiomyoma variants. Nature Publishing Group UK 2021-09-27 /pmc/articles/PMC8476551/ /pubmed/34580348 http://dx.doi.org/10.1038/s41598-021-98473-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Himoto, Yuki Kido, Aki Sakata, Akihiko Moribata, Yusaku Kurata, Yasuhisa Suzuki, Ayako Matsumura, Noriomi Shitano, Fuki Kawahara, Seiya Kubo, Shigeto Umeoka, Shigeaki Minamiguchi, Sachiko Mandai, Masaki Differentiation of uterine low-grade endometrial stromal sarcoma from rare leiomyoma variants by magnetic resonance imaging |
title | Differentiation of uterine low-grade endometrial stromal sarcoma from rare leiomyoma variants by magnetic resonance imaging |
title_full | Differentiation of uterine low-grade endometrial stromal sarcoma from rare leiomyoma variants by magnetic resonance imaging |
title_fullStr | Differentiation of uterine low-grade endometrial stromal sarcoma from rare leiomyoma variants by magnetic resonance imaging |
title_full_unstemmed | Differentiation of uterine low-grade endometrial stromal sarcoma from rare leiomyoma variants by magnetic resonance imaging |
title_short | Differentiation of uterine low-grade endometrial stromal sarcoma from rare leiomyoma variants by magnetic resonance imaging |
title_sort | differentiation of uterine low-grade endometrial stromal sarcoma from rare leiomyoma variants by magnetic resonance imaging |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8476551/ https://www.ncbi.nlm.nih.gov/pubmed/34580348 http://dx.doi.org/10.1038/s41598-021-98473-z |
work_keys_str_mv | AT himotoyuki differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT kidoaki differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT sakataakihiko differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT moribatayusaku differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT kuratayasuhisa differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT suzukiayako differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT matsumuranoriomi differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT shitanofuki differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT kawaharaseiya differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT kuboshigeto differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT umeokashigeaki differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT minamiguchisachiko differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging AT mandaimasaki differentiationofuterinelowgradeendometrialstromalsarcomafromrareleiomyomavariantsbymagneticresonanceimaging |