Cargando…

Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques

OBJECTIVE: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance i...

Descripción completa

Detalles Bibliográficos
Autores principales: Taeger, Johannes, Müller-Graff, Franz Tassilo, Ilgen, Lukas, Schendzielorz, Phillip, Hagen, Rudolf, Neun, Tilman, Rak, Kristen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8477698/
https://www.ncbi.nlm.nih.gov/pubmed/34595367
http://dx.doi.org/10.1177/2473974X211045312
_version_ 1784575896642912256
author Taeger, Johannes
Müller-Graff, Franz Tassilo
Ilgen, Lukas
Schendzielorz, Phillip
Hagen, Rudolf
Neun, Tilman
Rak, Kristen
author_facet Taeger, Johannes
Müller-Graff, Franz Tassilo
Ilgen, Lukas
Schendzielorz, Phillip
Hagen, Rudolf
Neun, Tilman
Rak, Kristen
author_sort Taeger, Johannes
collection PubMed
description OBJECTIVE: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI). Therefore, the presented study aims to fill this gap by estimating CDL in MRI and comparing it with multislice computed tomography (CT). STUDY DESIGN: Retrospective data analyses of 42 cochleae. SETTING: Tertiary care medical center. METHODS: Diameter (A value) and width (B value) of the cochlea were measured in HOROS software. The CDL and the 2-turn length were determined by the elliptic circular approximation (ECA). In addition, the CDL, the 2-turn length, and the angular length were determined via HOROS software by the multiplanar reconstruction (MPR) method. RESULTS: CDL values were significantly shorter in MRI by MPR (d = 1.38 mm, P < .001) but not by ECA. Similar 2-turn length measurements were significantly lower in MRI by MPR (d = 1.67 mm) and ECA (d = 1.19 mm, both P < .001). In contrast, angular length was significantly higher in MRI (d = 26.79°, P < .001). When the values were set in relation to the frequencies of the cochlea, no clinically relevant differences were estimated (58 Hz at 28-mm CDL). CONCLUSION: In the presented study, CDL was investigated in CT and MRI by using different approaches. Since no clinically relevant differences were found, diagnostics with radiation may be omitted prior to cochlear implantation; thus, a concept of radiation-free cochlear implantation could be established.
format Online
Article
Text
id pubmed-8477698
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-84776982021-09-29 Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques Taeger, Johannes Müller-Graff, Franz Tassilo Ilgen, Lukas Schendzielorz, Phillip Hagen, Rudolf Neun, Tilman Rak, Kristen OTO Open Original Research OBJECTIVE: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI). Therefore, the presented study aims to fill this gap by estimating CDL in MRI and comparing it with multislice computed tomography (CT). STUDY DESIGN: Retrospective data analyses of 42 cochleae. SETTING: Tertiary care medical center. METHODS: Diameter (A value) and width (B value) of the cochlea were measured in HOROS software. The CDL and the 2-turn length were determined by the elliptic circular approximation (ECA). In addition, the CDL, the 2-turn length, and the angular length were determined via HOROS software by the multiplanar reconstruction (MPR) method. RESULTS: CDL values were significantly shorter in MRI by MPR (d = 1.38 mm, P < .001) but not by ECA. Similar 2-turn length measurements were significantly lower in MRI by MPR (d = 1.67 mm) and ECA (d = 1.19 mm, both P < .001). In contrast, angular length was significantly higher in MRI (d = 26.79°, P < .001). When the values were set in relation to the frequencies of the cochlea, no clinically relevant differences were estimated (58 Hz at 28-mm CDL). CONCLUSION: In the presented study, CDL was investigated in CT and MRI by using different approaches. Since no clinically relevant differences were found, diagnostics with radiation may be omitted prior to cochlear implantation; thus, a concept of radiation-free cochlear implantation could be established. SAGE Publications 2021-09-24 /pmc/articles/PMC8477698/ /pubmed/34595367 http://dx.doi.org/10.1177/2473974X211045312 Text en © The Authors 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Taeger, Johannes
Müller-Graff, Franz Tassilo
Ilgen, Lukas
Schendzielorz, Phillip
Hagen, Rudolf
Neun, Tilman
Rak, Kristen
Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques
title Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques
title_full Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques
title_fullStr Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques
title_full_unstemmed Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques
title_short Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques
title_sort cochlear duct length measurements in computed tomography and magnetic resonance imaging using newly developed techniques
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8477698/
https://www.ncbi.nlm.nih.gov/pubmed/34595367
http://dx.doi.org/10.1177/2473974X211045312
work_keys_str_mv AT taegerjohannes cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques
AT mullergrafffranztassilo cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques
AT ilgenlukas cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques
AT schendzielorzphillip cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques
AT hagenrudolf cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques
AT neuntilman cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques
AT rakkristen cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques