Cargando…
Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques
OBJECTIVE: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance i...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8477698/ https://www.ncbi.nlm.nih.gov/pubmed/34595367 http://dx.doi.org/10.1177/2473974X211045312 |
_version_ | 1784575896642912256 |
---|---|
author | Taeger, Johannes Müller-Graff, Franz Tassilo Ilgen, Lukas Schendzielorz, Phillip Hagen, Rudolf Neun, Tilman Rak, Kristen |
author_facet | Taeger, Johannes Müller-Graff, Franz Tassilo Ilgen, Lukas Schendzielorz, Phillip Hagen, Rudolf Neun, Tilman Rak, Kristen |
author_sort | Taeger, Johannes |
collection | PubMed |
description | OBJECTIVE: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI). Therefore, the presented study aims to fill this gap by estimating CDL in MRI and comparing it with multislice computed tomography (CT). STUDY DESIGN: Retrospective data analyses of 42 cochleae. SETTING: Tertiary care medical center. METHODS: Diameter (A value) and width (B value) of the cochlea were measured in HOROS software. The CDL and the 2-turn length were determined by the elliptic circular approximation (ECA). In addition, the CDL, the 2-turn length, and the angular length were determined via HOROS software by the multiplanar reconstruction (MPR) method. RESULTS: CDL values were significantly shorter in MRI by MPR (d = 1.38 mm, P < .001) but not by ECA. Similar 2-turn length measurements were significantly lower in MRI by MPR (d = 1.67 mm) and ECA (d = 1.19 mm, both P < .001). In contrast, angular length was significantly higher in MRI (d = 26.79°, P < .001). When the values were set in relation to the frequencies of the cochlea, no clinically relevant differences were estimated (58 Hz at 28-mm CDL). CONCLUSION: In the presented study, CDL was investigated in CT and MRI by using different approaches. Since no clinically relevant differences were found, diagnostics with radiation may be omitted prior to cochlear implantation; thus, a concept of radiation-free cochlear implantation could be established. |
format | Online Article Text |
id | pubmed-8477698 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-84776982021-09-29 Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques Taeger, Johannes Müller-Graff, Franz Tassilo Ilgen, Lukas Schendzielorz, Phillip Hagen, Rudolf Neun, Tilman Rak, Kristen OTO Open Original Research OBJECTIVE: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI). Therefore, the presented study aims to fill this gap by estimating CDL in MRI and comparing it with multislice computed tomography (CT). STUDY DESIGN: Retrospective data analyses of 42 cochleae. SETTING: Tertiary care medical center. METHODS: Diameter (A value) and width (B value) of the cochlea were measured in HOROS software. The CDL and the 2-turn length were determined by the elliptic circular approximation (ECA). In addition, the CDL, the 2-turn length, and the angular length were determined via HOROS software by the multiplanar reconstruction (MPR) method. RESULTS: CDL values were significantly shorter in MRI by MPR (d = 1.38 mm, P < .001) but not by ECA. Similar 2-turn length measurements were significantly lower in MRI by MPR (d = 1.67 mm) and ECA (d = 1.19 mm, both P < .001). In contrast, angular length was significantly higher in MRI (d = 26.79°, P < .001). When the values were set in relation to the frequencies of the cochlea, no clinically relevant differences were estimated (58 Hz at 28-mm CDL). CONCLUSION: In the presented study, CDL was investigated in CT and MRI by using different approaches. Since no clinically relevant differences were found, diagnostics with radiation may be omitted prior to cochlear implantation; thus, a concept of radiation-free cochlear implantation could be established. SAGE Publications 2021-09-24 /pmc/articles/PMC8477698/ /pubmed/34595367 http://dx.doi.org/10.1177/2473974X211045312 Text en © The Authors 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Research Taeger, Johannes Müller-Graff, Franz Tassilo Ilgen, Lukas Schendzielorz, Phillip Hagen, Rudolf Neun, Tilman Rak, Kristen Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques |
title | Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques |
title_full | Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques |
title_fullStr | Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques |
title_full_unstemmed | Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques |
title_short | Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques |
title_sort | cochlear duct length measurements in computed tomography and magnetic resonance imaging using newly developed techniques |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8477698/ https://www.ncbi.nlm.nih.gov/pubmed/34595367 http://dx.doi.org/10.1177/2473974X211045312 |
work_keys_str_mv | AT taegerjohannes cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques AT mullergrafffranztassilo cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques AT ilgenlukas cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques AT schendzielorzphillip cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques AT hagenrudolf cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques AT neuntilman cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques AT rakkristen cochlearductlengthmeasurementsincomputedtomographyandmagneticresonanceimagingusingnewlydevelopedtechniques |