Cargando…
Ten‐Year Clinical Outcomes of Biodegradable Versus Durable Polymer New‐Generation Drug‐Eluting Stent in Patients With Coronary Artery Disease With and Without Diabetes Mellitus
BACKGROUND: Extended long‐term follow‐up data of new‐generation drug‐eluting stents in patients with diabetes mellitus is scant. The aim of this study is to assess the 10‐year clinical outcome of new‐generation biodegradable polymer‐based sirolimus‐eluting stents (Yukon Choice PC) versus permanent p...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8477883/ https://www.ncbi.nlm.nih.gov/pubmed/34075784 http://dx.doi.org/10.1161/JAHA.120.020165 |
_version_ | 1784575940037181440 |
---|---|
author | Lenz, Tobias Koch, Tobias Joner, Michael Xhepa, Erion Wiebe, Jens Coughlan, J. J. Aytekin, Alp Ibrahim, Tareq Fusaro, Massimiliano Cassese, Salvatore Laugwitz, Karl‐Ludwig Schunkert, Heribert Kastrati, Adnan Kufner, Sebastian |
author_facet | Lenz, Tobias Koch, Tobias Joner, Michael Xhepa, Erion Wiebe, Jens Coughlan, J. J. Aytekin, Alp Ibrahim, Tareq Fusaro, Massimiliano Cassese, Salvatore Laugwitz, Karl‐Ludwig Schunkert, Heribert Kastrati, Adnan Kufner, Sebastian |
author_sort | Lenz, Tobias |
collection | PubMed |
description | BACKGROUND: Extended long‐term follow‐up data of new‐generation drug‐eluting stents in patients with diabetes mellitus is scant. The aim of this study is to assess the 10‐year clinical outcome of new‐generation biodegradable polymer‐based sirolimus‐eluting stents (Yukon Choice PC) versus permanent polymer‐based everolimus‐eluting stents (XIENCE) in patients with and without diabetes mellitus. METHODS AND RESULTS: In a prespecified subgroup analysis, outcomes of patients with or without diabetes mellitus treated with drug‐eluting stents were compared. The primary end point of this analysis was major adverse cardiac event, the composite of death, myocardial infarction, or target lesion revascularization. The analysis includes a total of 1951 patients (560 patients with and 1391 patients without diabetes mellitus) randomized to treatment with Yukon Choice PC (n=1299) or Xience (n=652). Regarding the primary end point, at 10 years patients with diabetes mellitus showed significantly higher major adverse cardiac event rates than patients without diabetes mellitus (P<0.001; hazard ratio [HR], 1.41; 95% CI, 1.22–1.63). There was no significant difference between patients treated with Yukon Choice PC versus Xience, neither in the subgroup of patients with (P=0.91; HR, 1.01; 95% CI, 0.79–1.30) nor without diabetes mellitus (P=0.50; HR, 0.94; 95% CI, 0.79–1.21). Rates of definite/probable stent thrombosis were 2.3% in patients with and 1.9% in patients without diabetes mellitus (HR, 1.27; 95% CI, 0.34–2.60; P=0.52), without significant differences between study devices. CONCLUSIONS: The clinical outcome of patients with diabetes after percutaneous coronary intervention with different new‐generation drug‐eluting stents is considerably worse than that of patients without diabetes mellitus, with event rates constantly increasing out to 10 years. REGISTRATION: URL: https://clinicaltrials.gov. Unique Identifier: NCT00598676. |
format | Online Article Text |
id | pubmed-8477883 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-84778832021-10-01 Ten‐Year Clinical Outcomes of Biodegradable Versus Durable Polymer New‐Generation Drug‐Eluting Stent in Patients With Coronary Artery Disease With and Without Diabetes Mellitus Lenz, Tobias Koch, Tobias Joner, Michael Xhepa, Erion Wiebe, Jens Coughlan, J. J. Aytekin, Alp Ibrahim, Tareq Fusaro, Massimiliano Cassese, Salvatore Laugwitz, Karl‐Ludwig Schunkert, Heribert Kastrati, Adnan Kufner, Sebastian J Am Heart Assoc Original Research BACKGROUND: Extended long‐term follow‐up data of new‐generation drug‐eluting stents in patients with diabetes mellitus is scant. The aim of this study is to assess the 10‐year clinical outcome of new‐generation biodegradable polymer‐based sirolimus‐eluting stents (Yukon Choice PC) versus permanent polymer‐based everolimus‐eluting stents (XIENCE) in patients with and without diabetes mellitus. METHODS AND RESULTS: In a prespecified subgroup analysis, outcomes of patients with or without diabetes mellitus treated with drug‐eluting stents were compared. The primary end point of this analysis was major adverse cardiac event, the composite of death, myocardial infarction, or target lesion revascularization. The analysis includes a total of 1951 patients (560 patients with and 1391 patients without diabetes mellitus) randomized to treatment with Yukon Choice PC (n=1299) or Xience (n=652). Regarding the primary end point, at 10 years patients with diabetes mellitus showed significantly higher major adverse cardiac event rates than patients without diabetes mellitus (P<0.001; hazard ratio [HR], 1.41; 95% CI, 1.22–1.63). There was no significant difference between patients treated with Yukon Choice PC versus Xience, neither in the subgroup of patients with (P=0.91; HR, 1.01; 95% CI, 0.79–1.30) nor without diabetes mellitus (P=0.50; HR, 0.94; 95% CI, 0.79–1.21). Rates of definite/probable stent thrombosis were 2.3% in patients with and 1.9% in patients without diabetes mellitus (HR, 1.27; 95% CI, 0.34–2.60; P=0.52), without significant differences between study devices. CONCLUSIONS: The clinical outcome of patients with diabetes after percutaneous coronary intervention with different new‐generation drug‐eluting stents is considerably worse than that of patients without diabetes mellitus, with event rates constantly increasing out to 10 years. REGISTRATION: URL: https://clinicaltrials.gov. Unique Identifier: NCT00598676. John Wiley and Sons Inc. 2021-06-02 /pmc/articles/PMC8477883/ /pubmed/34075784 http://dx.doi.org/10.1161/JAHA.120.020165 Text en © 2021 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Research Lenz, Tobias Koch, Tobias Joner, Michael Xhepa, Erion Wiebe, Jens Coughlan, J. J. Aytekin, Alp Ibrahim, Tareq Fusaro, Massimiliano Cassese, Salvatore Laugwitz, Karl‐Ludwig Schunkert, Heribert Kastrati, Adnan Kufner, Sebastian Ten‐Year Clinical Outcomes of Biodegradable Versus Durable Polymer New‐Generation Drug‐Eluting Stent in Patients With Coronary Artery Disease With and Without Diabetes Mellitus |
title | Ten‐Year Clinical Outcomes of Biodegradable Versus Durable Polymer New‐Generation Drug‐Eluting Stent in Patients With Coronary Artery Disease With and Without Diabetes Mellitus |
title_full | Ten‐Year Clinical Outcomes of Biodegradable Versus Durable Polymer New‐Generation Drug‐Eluting Stent in Patients With Coronary Artery Disease With and Without Diabetes Mellitus |
title_fullStr | Ten‐Year Clinical Outcomes of Biodegradable Versus Durable Polymer New‐Generation Drug‐Eluting Stent in Patients With Coronary Artery Disease With and Without Diabetes Mellitus |
title_full_unstemmed | Ten‐Year Clinical Outcomes of Biodegradable Versus Durable Polymer New‐Generation Drug‐Eluting Stent in Patients With Coronary Artery Disease With and Without Diabetes Mellitus |
title_short | Ten‐Year Clinical Outcomes of Biodegradable Versus Durable Polymer New‐Generation Drug‐Eluting Stent in Patients With Coronary Artery Disease With and Without Diabetes Mellitus |
title_sort | ten‐year clinical outcomes of biodegradable versus durable polymer new‐generation drug‐eluting stent in patients with coronary artery disease with and without diabetes mellitus |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8477883/ https://www.ncbi.nlm.nih.gov/pubmed/34075784 http://dx.doi.org/10.1161/JAHA.120.020165 |
work_keys_str_mv | AT lenztobias tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT kochtobias tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT jonermichael tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT xhepaerion tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT wiebejens tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT coughlanjj tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT aytekinalp tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT ibrahimtareq tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT fusaromassimiliano tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT cassesesalvatore tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT laugwitzkarlludwig tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT schunkertheribert tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT kastratiadnan tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT kufnersebastian tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus AT tenyearclinicaloutcomesofbiodegradableversusdurablepolymernewgenerationdrugelutingstentinpatientswithcoronaryarterydiseasewithandwithoutdiabetesmellitus |