Cargando…
Topography-Guided Trans-Epithelial No-Touch Photorefractive Keratectomy for High Irregular Astigmatism After Penetrating Keratoplasty: A Prospective 12-Months Follow-Up
PURPOSE: To describe the efficacy and safety of topography-guided trans-epithelial no-touch photorefractive keratectomy (PRK) for the correction of highly irregular astigmatism after penetrating keratoplasty (PK). PATIENTS AND METHODS: A prospective study was conducted on 12 eyes of 12 patients affe...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8478484/ https://www.ncbi.nlm.nih.gov/pubmed/34594105 http://dx.doi.org/10.2147/TCRM.S329932 |
Sumario: | PURPOSE: To describe the efficacy and safety of topography-guided trans-epithelial no-touch photorefractive keratectomy (PRK) for the correction of highly irregular astigmatism after penetrating keratoplasty (PK). PATIENTS AND METHODS: A prospective study was conducted on 12 eyes of 12 patients affected by highly irregular astigmatism after PK for keratoconus. Each patient underwent a single-step topography-guided trans-epithelial ablation (CIPTA(®)2 software, iVis Technologies). Corneal topography data as well as uncorrected (UDVA) and corrected distance visual acuity (CDVA) and spherical equivalent (SEQ) were collected preoperatively (T0) and at 1 (T1), 3 (T2) and 12 (T3) months after surgery. RESULTS: Mean UDVA and CDVA significantly improved, respectively, from 1.22±0.17 and 0.18±0.03LogMAR at T0 to 0.63±0.17 (CI 95%, P<0.001) and 0.04±0.03LogMAR at T3 (CI 95%, P<0.001). Mean SEQ significantly decreased from −3.75±1.32 to –1.60±1.32D (CI 95%, P<0.02). Mean subjective refractive astigmatism (SRAST) and mean keratometry astigmatism (SimK) significantly decreased, respectively, from 7.83±0.98 and 8.10±1.48D to 2.83±0.98 and 5.29±1.48D (CI 95%, P<0.001). Corneal Morphological Irregularity index (CMI) significantly decreased from 62.76±7.26 µm to 23.24±7.26 µm (CI 95%, P<0.001). Apart from a single episode of graft rejection 5 days after ablation, successfully reverted with topical steroids, no other complications were noted. A mild corneal haze was observed in two eyes (16.7%) at 3 months post-PRK, and no regression was observed at 12 months. CONCLUSION: Our study demonstrates the safety and long-term effectiveness of a trans-epithelial topography-guided ablation in the treatment of post-PK highly irregular astigmatism. |
---|