Cargando…
New cut-off point for D-dimer in the diagnosis of pulmonary embolism during pregnancy
BACKGROUND: Considering that pulmonary embolism (PE) is one of the leading causes of mortality among pregnant women and that the D-dimer level in pregnancy can be highly fluctuating, a new and reliable D-dimer reference value is essential to identifying PE in this group of patients. Hence, the prese...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Hematology; Korean Society of Blood and Marrow Transplantation; Korean Society of Pediatric Hematology-Oncology; Korean Society on Thrombosis and Hemostasis
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8478618/ https://www.ncbi.nlm.nih.gov/pubmed/34400590 http://dx.doi.org/10.5045/br.2021.2021069 |
_version_ | 1784576101267275776 |
---|---|
author | Sadeghi, Somayeh Golshani, Marjan Safaeian, Bahareh |
author_facet | Sadeghi, Somayeh Golshani, Marjan Safaeian, Bahareh |
author_sort | Sadeghi, Somayeh |
collection | PubMed |
description | BACKGROUND: Considering that pulmonary embolism (PE) is one of the leading causes of mortality among pregnant women and that the D-dimer level in pregnancy can be highly fluctuating, a new and reliable D-dimer reference value is essential to identifying PE in this group of patients. Hence, the present study aimed to evaluate the diagnostic effect of D-dimer testing in pregnant women with suspected PE. METHODS: This study recruited 100 women with confirmed pregnancy or six weeks after delivery or abortion with suspected PE symptoms. Wells criteria, D-dimer values, and pregnancy trimesters were recorded. Definitive PE results were obtained using multidetector computed tomography (MDCT) or pulmonary ventilation/perfusion scans. RESULTS: D-dimer cut-off point in PE diagnosis was higher than 1,447 mg/L [sensitivity, 87.5%; specificity, 63.04%; area under the curve (AUC)=0.735; P=0.003]. In addition, the combination of Wells criteria with the D-dimer test indicated that the cut-off points of D-dimer in PE likely and unlikely women were 1,962 and 1,447 mg/L, respectively, and had acceptable and significant diagnostic value in PE detection. In addition, the diagnostic value of D-dimer in pregnancy trimesters was not found to be significant (P>0.05). CONCLUSION: The new cut-off points of 1,447 and 1,962 mg/L were determined for D-dimer in pregnant women with likely and unlikely PE, respectively. Moreover, the new cut-off points in the first and second trimesters of pregnancy were 1,701 mg/L and 1,451 mg/L, respectively, which indicated no statistically acceptable diagnostic value. |
format | Online Article Text |
id | pubmed-8478618 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Korean Society of Hematology; Korean Society of Blood and Marrow Transplantation; Korean Society of Pediatric Hematology-Oncology; Korean Society on Thrombosis and Hemostasis |
record_format | MEDLINE/PubMed |
spelling | pubmed-84786182021-10-09 New cut-off point for D-dimer in the diagnosis of pulmonary embolism during pregnancy Sadeghi, Somayeh Golshani, Marjan Safaeian, Bahareh Blood Res Original Article BACKGROUND: Considering that pulmonary embolism (PE) is one of the leading causes of mortality among pregnant women and that the D-dimer level in pregnancy can be highly fluctuating, a new and reliable D-dimer reference value is essential to identifying PE in this group of patients. Hence, the present study aimed to evaluate the diagnostic effect of D-dimer testing in pregnant women with suspected PE. METHODS: This study recruited 100 women with confirmed pregnancy or six weeks after delivery or abortion with suspected PE symptoms. Wells criteria, D-dimer values, and pregnancy trimesters were recorded. Definitive PE results were obtained using multidetector computed tomography (MDCT) or pulmonary ventilation/perfusion scans. RESULTS: D-dimer cut-off point in PE diagnosis was higher than 1,447 mg/L [sensitivity, 87.5%; specificity, 63.04%; area under the curve (AUC)=0.735; P=0.003]. In addition, the combination of Wells criteria with the D-dimer test indicated that the cut-off points of D-dimer in PE likely and unlikely women were 1,962 and 1,447 mg/L, respectively, and had acceptable and significant diagnostic value in PE detection. In addition, the diagnostic value of D-dimer in pregnancy trimesters was not found to be significant (P>0.05). CONCLUSION: The new cut-off points of 1,447 and 1,962 mg/L were determined for D-dimer in pregnant women with likely and unlikely PE, respectively. Moreover, the new cut-off points in the first and second trimesters of pregnancy were 1,701 mg/L and 1,451 mg/L, respectively, which indicated no statistically acceptable diagnostic value. Korean Society of Hematology; Korean Society of Blood and Marrow Transplantation; Korean Society of Pediatric Hematology-Oncology; Korean Society on Thrombosis and Hemostasis 2021-09-30 2021-09-30 /pmc/articles/PMC8478618/ /pubmed/34400590 http://dx.doi.org/10.5045/br.2021.2021069 Text en © 2021 Korean Society of Hematology https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Sadeghi, Somayeh Golshani, Marjan Safaeian, Bahareh New cut-off point for D-dimer in the diagnosis of pulmonary embolism during pregnancy |
title | New cut-off point for D-dimer in the diagnosis of pulmonary embolism during pregnancy |
title_full | New cut-off point for D-dimer in the diagnosis of pulmonary embolism during pregnancy |
title_fullStr | New cut-off point for D-dimer in the diagnosis of pulmonary embolism during pregnancy |
title_full_unstemmed | New cut-off point for D-dimer in the diagnosis of pulmonary embolism during pregnancy |
title_short | New cut-off point for D-dimer in the diagnosis of pulmonary embolism during pregnancy |
title_sort | new cut-off point for d-dimer in the diagnosis of pulmonary embolism during pregnancy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8478618/ https://www.ncbi.nlm.nih.gov/pubmed/34400590 http://dx.doi.org/10.5045/br.2021.2021069 |
work_keys_str_mv | AT sadeghisomayeh newcutoffpointforddimerinthediagnosisofpulmonaryembolismduringpregnancy AT golshanimarjan newcutoffpointforddimerinthediagnosisofpulmonaryembolismduringpregnancy AT safaeianbahareh newcutoffpointforddimerinthediagnosisofpulmonaryembolismduringpregnancy |