In vitro erosive dental wear measured with a 3D intraoral scanner – a pilot study

INTRODUCTION: Erosive tooth wear is a common condition in modern societies. Without preventive measures, it can lead to dentine hypersensitivity, loss of vertical dimension of occlusion and aesthetic problems [1]. Suitable diagnostic tools need to be developed for use in prevalence studies in order...

Descripción completa

Detalles Bibliográficos
Autores principales: Gouveia, Rita, Vieira, Ana Maria, Mendes, José João, Rua, João
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8480822/
http://dx.doi.org/10.1080/07853890.2021.1897348
_version_ 1784576546218967040
author Gouveia, Rita
Vieira, Ana Maria
Mendes, José João
Rua, João
author_facet Gouveia, Rita
Vieira, Ana Maria
Mendes, José João
Rua, João
author_sort Gouveia, Rita
collection PubMed
description INTRODUCTION: Erosive tooth wear is a common condition in modern societies. Without preventive measures, it can lead to dentine hypersensitivity, loss of vertical dimension of occlusion and aesthetic problems [1]. Suitable diagnostic tools need to be developed for use in prevalence studies in order to compare the results of different investigations as well as for monitoring the progression of tooth wear, as highlighted in the European Consensus statement on management guidelines for severe tooth wear [2]. The use of 3 D intraoral scans has increased, however surface alignment for comparison of sequential scans is a complex process. The goal of this in vitro pilot study was to develop a protocol for a future study on the accuracy of an intraoral scanner and software for the measurement of erosive wear. Focus was made on the development of a reliable method for superimposition and subtraction of intraoral scans, facilitating the measurement of wear progression using volume change. MATERIALS AND METHODS: Ethical approval was obtained. An extracted sound third molar was cut in the mesiodistal direction, approximately 4 mm above the cementoenamel junction. The apical part was discarded. The coronal part was bonded to a ceramic block with pre-heated composite resin and scanned at baseline with an intraoral scanner (IOS) (3 M True Definition Scanner, 3 M, USA). Erosion was simulated by immersion of the sample in the soft drink Sprite® (not degassed, pH of 2,81), under controlled agitation, 7 times 1 h. A baseline scan was made before erosion and the scans were repeated after each erosive challenge of 1 h. All measurements were made with Geomagic Control (3 D Systems, Darmstadt, Germany). The scans were imported one by one and aligned with a baseline scan. Then with all the scans aligned with the baseline, they were altogether cut at the same plane resulting in 3 D images for which was possible to determine the volume (Figure 1). Wear was calculated using volume change. RESULTS: Calculated volume change after 1, 2, 3, 4, 5, 6, and 7 h erosion was −5.63, 3.48, 0.02, −2.48, −3.32, −1.62 and −3.12 mm(3), respectively. Macroscopic enamel demineralisation was observed with the naked eye after 2 h erosion. Areas of enamel loss were clearly observed in the scans and seemed to increase in area and depth with increasing erosion time (Figure 2). DISCUSSION AND CONCLUSIONS: Under the limitations of this pilot study, it can be concluded that the present protocol allows enamel loss detection with the IOS, and that the customised alignment of the scans is necessary for reliable volume measurements.
format Online
Article
Text
id pubmed-8480822
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-84808222022-03-03 In vitro erosive dental wear measured with a 3D intraoral scanner – a pilot study Gouveia, Rita Vieira, Ana Maria Mendes, José João Rua, João Ann Med Abstract 219 INTRODUCTION: Erosive tooth wear is a common condition in modern societies. Without preventive measures, it can lead to dentine hypersensitivity, loss of vertical dimension of occlusion and aesthetic problems [1]. Suitable diagnostic tools need to be developed for use in prevalence studies in order to compare the results of different investigations as well as for monitoring the progression of tooth wear, as highlighted in the European Consensus statement on management guidelines for severe tooth wear [2]. The use of 3 D intraoral scans has increased, however surface alignment for comparison of sequential scans is a complex process. The goal of this in vitro pilot study was to develop a protocol for a future study on the accuracy of an intraoral scanner and software for the measurement of erosive wear. Focus was made on the development of a reliable method for superimposition and subtraction of intraoral scans, facilitating the measurement of wear progression using volume change. MATERIALS AND METHODS: Ethical approval was obtained. An extracted sound third molar was cut in the mesiodistal direction, approximately 4 mm above the cementoenamel junction. The apical part was discarded. The coronal part was bonded to a ceramic block with pre-heated composite resin and scanned at baseline with an intraoral scanner (IOS) (3 M True Definition Scanner, 3 M, USA). Erosion was simulated by immersion of the sample in the soft drink Sprite® (not degassed, pH of 2,81), under controlled agitation, 7 times 1 h. A baseline scan was made before erosion and the scans were repeated after each erosive challenge of 1 h. All measurements were made with Geomagic Control (3 D Systems, Darmstadt, Germany). The scans were imported one by one and aligned with a baseline scan. Then with all the scans aligned with the baseline, they were altogether cut at the same plane resulting in 3 D images for which was possible to determine the volume (Figure 1). Wear was calculated using volume change. RESULTS: Calculated volume change after 1, 2, 3, 4, 5, 6, and 7 h erosion was −5.63, 3.48, 0.02, −2.48, −3.32, −1.62 and −3.12 mm(3), respectively. Macroscopic enamel demineralisation was observed with the naked eye after 2 h erosion. Areas of enamel loss were clearly observed in the scans and seemed to increase in area and depth with increasing erosion time (Figure 2). DISCUSSION AND CONCLUSIONS: Under the limitations of this pilot study, it can be concluded that the present protocol allows enamel loss detection with the IOS, and that the customised alignment of the scans is necessary for reliable volume measurements. Taylor & Francis 2021-09-28 /pmc/articles/PMC8480822/ http://dx.doi.org/10.1080/07853890.2021.1897348 Text en © 2021 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Abstract 219
Gouveia, Rita
Vieira, Ana Maria
Mendes, José João
Rua, João
In vitro erosive dental wear measured with a 3D intraoral scanner – a pilot study
title In vitro erosive dental wear measured with a 3D intraoral scanner – a pilot study
title_full In vitro erosive dental wear measured with a 3D intraoral scanner – a pilot study
title_fullStr In vitro erosive dental wear measured with a 3D intraoral scanner – a pilot study
title_full_unstemmed In vitro erosive dental wear measured with a 3D intraoral scanner – a pilot study
title_short In vitro erosive dental wear measured with a 3D intraoral scanner – a pilot study
title_sort in vitro erosive dental wear measured with a 3d intraoral scanner – a pilot study
topic Abstract 219
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8480822/
http://dx.doi.org/10.1080/07853890.2021.1897348
work_keys_str_mv AT gouveiarita invitroerosivedentalwearmeasuredwitha3dintraoralscannerapilotstudy
AT vieiraanamaria invitroerosivedentalwearmeasuredwitha3dintraoralscannerapilotstudy
AT mendesjosejoao invitroerosivedentalwearmeasuredwitha3dintraoralscannerapilotstudy
AT ruajoao invitroerosivedentalwearmeasuredwitha3dintraoralscannerapilotstudy