Cargando…
Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study
BACKGROUND: The increase in cardiovascular disease cases that require minimally invasive treatment is inducing a new need to train physicians to perform them safely and effectively. Nevertheless, adaptation to simulation-based training has been slow, especially for complex procedures. OBJECTIVES: We...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8481152/ https://www.ncbi.nlm.nih.gov/pubmed/34100226 http://dx.doi.org/10.1007/s13239-021-00549-4 |
_version_ | 1784576622042546176 |
---|---|
author | Zimmermann, Jan Michael Arduini, Mattia Vicentini, Luca Maisano, Francesco Meboldt, Mirko |
author_facet | Zimmermann, Jan Michael Arduini, Mattia Vicentini, Luca Maisano, Francesco Meboldt, Mirko |
author_sort | Zimmermann, Jan Michael |
collection | PubMed |
description | BACKGROUND: The increase in cardiovascular disease cases that require minimally invasive treatment is inducing a new need to train physicians to perform them safely and effectively. Nevertheless, adaptation to simulation-based training has been slow, especially for complex procedures. OBJECTIVES: We describe a newly developed mitral valve repair (MVR) simulator, equipped with new objective performance assessment methods, with an emphasis on its use for training the MitraClip™ procedure. METHODS: The MVR contains phantoms of all anatomical structures encountered during mitral valve repair with a transvenous, transseptal approach. In addition, several cameras, line lasers, and ultraviolet lights are used to mimic echocardiographic and fluoroscopic imaging and with a remote eye tracker the cognitive behaviour of the operator is recorded. A pilot study with a total of 9 interventional cardiologists, cardiac surgeons and technical experts was conducted. All participants performed the MitraClip procedure on the MVR simulator using standard interventional tools. Subsequently, each participant completed a structured questionnaire to assess the simulator. RESULTS: The simulator functioned well, and the implemented objective performance assessment methods worked reliably. Key performance metrics such as x-ray usage were comparable with results from studies assessing these metrics in real interventions. Fluoroscopy imaging is realistic for the transseptal puncture but reaches its limits during the final steps of the procedure. CONCLUSION: The functionality and objective performance assessment of the MVR simulator were demonstrated. Especially for complex procedures such as the MitraClip procedure, this simulator offers a suitable platform for risk-free training and education. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13239-021-00549-4. |
format | Online Article Text |
id | pubmed-8481152 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-84811522021-10-08 Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study Zimmermann, Jan Michael Arduini, Mattia Vicentini, Luca Maisano, Francesco Meboldt, Mirko Cardiovasc Eng Technol Original Article BACKGROUND: The increase in cardiovascular disease cases that require minimally invasive treatment is inducing a new need to train physicians to perform them safely and effectively. Nevertheless, adaptation to simulation-based training has been slow, especially for complex procedures. OBJECTIVES: We describe a newly developed mitral valve repair (MVR) simulator, equipped with new objective performance assessment methods, with an emphasis on its use for training the MitraClip™ procedure. METHODS: The MVR contains phantoms of all anatomical structures encountered during mitral valve repair with a transvenous, transseptal approach. In addition, several cameras, line lasers, and ultraviolet lights are used to mimic echocardiographic and fluoroscopic imaging and with a remote eye tracker the cognitive behaviour of the operator is recorded. A pilot study with a total of 9 interventional cardiologists, cardiac surgeons and technical experts was conducted. All participants performed the MitraClip procedure on the MVR simulator using standard interventional tools. Subsequently, each participant completed a structured questionnaire to assess the simulator. RESULTS: The simulator functioned well, and the implemented objective performance assessment methods worked reliably. Key performance metrics such as x-ray usage were comparable with results from studies assessing these metrics in real interventions. Fluoroscopy imaging is realistic for the transseptal puncture but reaches its limits during the final steps of the procedure. CONCLUSION: The functionality and objective performance assessment of the MVR simulator were demonstrated. Especially for complex procedures such as the MitraClip procedure, this simulator offers a suitable platform for risk-free training and education. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13239-021-00549-4. Springer International Publishing 2021-06-07 2021 /pmc/articles/PMC8481152/ /pubmed/34100226 http://dx.doi.org/10.1007/s13239-021-00549-4 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Zimmermann, Jan Michael Arduini, Mattia Vicentini, Luca Maisano, Francesco Meboldt, Mirko Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study |
title | Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study |
title_full | Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study |
title_fullStr | Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study |
title_full_unstemmed | Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study |
title_short | Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study |
title_sort | transcatheter mitral valve repair simulator equipped with eye tracking based performance assessment capabilities: a pilot study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8481152/ https://www.ncbi.nlm.nih.gov/pubmed/34100226 http://dx.doi.org/10.1007/s13239-021-00549-4 |
work_keys_str_mv | AT zimmermannjanmichael transcathetermitralvalverepairsimulatorequippedwitheyetrackingbasedperformanceassessmentcapabilitiesapilotstudy AT arduinimattia transcathetermitralvalverepairsimulatorequippedwitheyetrackingbasedperformanceassessmentcapabilitiesapilotstudy AT vicentiniluca transcathetermitralvalverepairsimulatorequippedwitheyetrackingbasedperformanceassessmentcapabilitiesapilotstudy AT maisanofrancesco transcathetermitralvalverepairsimulatorequippedwitheyetrackingbasedperformanceassessmentcapabilitiesapilotstudy AT meboldtmirko transcathetermitralvalverepairsimulatorequippedwitheyetrackingbasedperformanceassessmentcapabilitiesapilotstudy |