Cargando…

Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study

BACKGROUND: The increase in cardiovascular disease cases that require minimally invasive treatment is inducing a new need to train physicians to perform them safely and effectively. Nevertheless, adaptation to simulation-based training has been slow, especially for complex procedures. OBJECTIVES: We...

Descripción completa

Detalles Bibliográficos
Autores principales: Zimmermann, Jan Michael, Arduini, Mattia, Vicentini, Luca, Maisano, Francesco, Meboldt, Mirko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8481152/
https://www.ncbi.nlm.nih.gov/pubmed/34100226
http://dx.doi.org/10.1007/s13239-021-00549-4
_version_ 1784576622042546176
author Zimmermann, Jan Michael
Arduini, Mattia
Vicentini, Luca
Maisano, Francesco
Meboldt, Mirko
author_facet Zimmermann, Jan Michael
Arduini, Mattia
Vicentini, Luca
Maisano, Francesco
Meboldt, Mirko
author_sort Zimmermann, Jan Michael
collection PubMed
description BACKGROUND: The increase in cardiovascular disease cases that require minimally invasive treatment is inducing a new need to train physicians to perform them safely and effectively. Nevertheless, adaptation to simulation-based training has been slow, especially for complex procedures. OBJECTIVES: We describe a newly developed mitral valve repair (MVR) simulator, equipped with new objective performance assessment methods, with an emphasis on its use for training the MitraClip™ procedure. METHODS: The MVR contains phantoms of all anatomical structures encountered during mitral valve repair with a transvenous, transseptal approach. In addition, several cameras, line lasers, and ultraviolet lights are used to mimic echocardiographic and fluoroscopic imaging and with a remote eye tracker the cognitive behaviour of the operator is recorded. A pilot study with a total of 9 interventional cardiologists, cardiac surgeons and technical experts was conducted. All participants performed the MitraClip procedure on the MVR simulator using standard interventional tools. Subsequently, each participant completed a structured questionnaire to assess the simulator. RESULTS: The simulator functioned well, and the implemented objective performance assessment methods worked reliably. Key performance metrics such as x-ray usage were comparable with results from studies assessing these metrics in real interventions. Fluoroscopy imaging is realistic for the transseptal puncture but reaches its limits during the final steps of the procedure. CONCLUSION: The functionality and objective performance assessment of the MVR simulator were demonstrated. Especially for complex procedures such as the MitraClip procedure, this simulator offers a suitable platform for risk-free training and education. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13239-021-00549-4.
format Online
Article
Text
id pubmed-8481152
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-84811522021-10-08 Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study Zimmermann, Jan Michael Arduini, Mattia Vicentini, Luca Maisano, Francesco Meboldt, Mirko Cardiovasc Eng Technol Original Article BACKGROUND: The increase in cardiovascular disease cases that require minimally invasive treatment is inducing a new need to train physicians to perform them safely and effectively. Nevertheless, adaptation to simulation-based training has been slow, especially for complex procedures. OBJECTIVES: We describe a newly developed mitral valve repair (MVR) simulator, equipped with new objective performance assessment methods, with an emphasis on its use for training the MitraClip™ procedure. METHODS: The MVR contains phantoms of all anatomical structures encountered during mitral valve repair with a transvenous, transseptal approach. In addition, several cameras, line lasers, and ultraviolet lights are used to mimic echocardiographic and fluoroscopic imaging and with a remote eye tracker the cognitive behaviour of the operator is recorded. A pilot study with a total of 9 interventional cardiologists, cardiac surgeons and technical experts was conducted. All participants performed the MitraClip procedure on the MVR simulator using standard interventional tools. Subsequently, each participant completed a structured questionnaire to assess the simulator. RESULTS: The simulator functioned well, and the implemented objective performance assessment methods worked reliably. Key performance metrics such as x-ray usage were comparable with results from studies assessing these metrics in real interventions. Fluoroscopy imaging is realistic for the transseptal puncture but reaches its limits during the final steps of the procedure. CONCLUSION: The functionality and objective performance assessment of the MVR simulator were demonstrated. Especially for complex procedures such as the MitraClip procedure, this simulator offers a suitable platform for risk-free training and education. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13239-021-00549-4. Springer International Publishing 2021-06-07 2021 /pmc/articles/PMC8481152/ /pubmed/34100226 http://dx.doi.org/10.1007/s13239-021-00549-4 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Zimmermann, Jan Michael
Arduini, Mattia
Vicentini, Luca
Maisano, Francesco
Meboldt, Mirko
Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study
title Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study
title_full Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study
title_fullStr Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study
title_full_unstemmed Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study
title_short Transcatheter Mitral Valve Repair Simulator Equipped with Eye Tracking Based Performance Assessment Capabilities: A Pilot Study
title_sort transcatheter mitral valve repair simulator equipped with eye tracking based performance assessment capabilities: a pilot study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8481152/
https://www.ncbi.nlm.nih.gov/pubmed/34100226
http://dx.doi.org/10.1007/s13239-021-00549-4
work_keys_str_mv AT zimmermannjanmichael transcathetermitralvalverepairsimulatorequippedwitheyetrackingbasedperformanceassessmentcapabilitiesapilotstudy
AT arduinimattia transcathetermitralvalverepairsimulatorequippedwitheyetrackingbasedperformanceassessmentcapabilitiesapilotstudy
AT vicentiniluca transcathetermitralvalverepairsimulatorequippedwitheyetrackingbasedperformanceassessmentcapabilitiesapilotstudy
AT maisanofrancesco transcathetermitralvalverepairsimulatorequippedwitheyetrackingbasedperformanceassessmentcapabilitiesapilotstudy
AT meboldtmirko transcathetermitralvalverepairsimulatorequippedwitheyetrackingbasedperformanceassessmentcapabilitiesapilotstudy