System introduction and evaluation of the first Chinese chest EIT device for ICU applications
Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system design o...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8481301/ https://www.ncbi.nlm.nih.gov/pubmed/34588556 http://dx.doi.org/10.1038/s41598-021-98793-0 |
_version_ | 1784576659391774720 |
---|---|
author | Qu, Shuo-Yao Dai, Meng Wu, Shuo Lv, Zhi-Rang Ti, Xin-Yu Fu, Feng |
author_facet | Qu, Shuo-Yao Dai, Meng Wu, Shuo Lv, Zhi-Rang Ti, Xin-Yu Fu, Feng |
author_sort | Qu, Shuo-Yao |
collection | PubMed |
description | Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system design of the hardware and software was briefly introduced. The performance of the system was compared to PulmoVista 500 (Dräger Medical) in healthy volunteers. The EIT system Pulmo EIT-100 consists of impedance measurement module, power supply module, PC all-in-one machine, medical cart and accessories. The performance of the system current source and voltage measurement unit was tested. A total of 50 healthy lung volunteers were prospectively examined. Subjects were asked to perform repetitive slow vital capacity (SVC) maneuvers with a spirometer. EIT measurements were performed in the following sequence during each SVC with: (1) Pulmo EIT-100, (2) PulmonVista500, (3) Pulmo EIT-100 and (4) PulmonVista500. Linearity and regional ventilation distribution of the reconstructed images from two devices were compared. The output frequency stability of the current source was 2 ppm. The amplitude error within one hour was less than 0.32‰. The output impedance of the current source was about 50kΩ. The signal-to-noise ratio of each measurement channel was ≥ 60 dB. For fixed resistance measurements, the measured values drifted about 0.08% within one hour. For human subjects, the correlations between the spirometry volume and EIT impedance from two devices were both 0.99 ± 0.01. No statistical significances were found in the parameters investigated. The repeatability (variability) of measures from the same device was comparable. Our EIT device delivers reliable data and might be used for patient measurement in a clinical setting. |
format | Online Article Text |
id | pubmed-8481301 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-84813012021-10-01 System introduction and evaluation of the first Chinese chest EIT device for ICU applications Qu, Shuo-Yao Dai, Meng Wu, Shuo Lv, Zhi-Rang Ti, Xin-Yu Fu, Feng Sci Rep Article Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system design of the hardware and software was briefly introduced. The performance of the system was compared to PulmoVista 500 (Dräger Medical) in healthy volunteers. The EIT system Pulmo EIT-100 consists of impedance measurement module, power supply module, PC all-in-one machine, medical cart and accessories. The performance of the system current source and voltage measurement unit was tested. A total of 50 healthy lung volunteers were prospectively examined. Subjects were asked to perform repetitive slow vital capacity (SVC) maneuvers with a spirometer. EIT measurements were performed in the following sequence during each SVC with: (1) Pulmo EIT-100, (2) PulmonVista500, (3) Pulmo EIT-100 and (4) PulmonVista500. Linearity and regional ventilation distribution of the reconstructed images from two devices were compared. The output frequency stability of the current source was 2 ppm. The amplitude error within one hour was less than 0.32‰. The output impedance of the current source was about 50kΩ. The signal-to-noise ratio of each measurement channel was ≥ 60 dB. For fixed resistance measurements, the measured values drifted about 0.08% within one hour. For human subjects, the correlations between the spirometry volume and EIT impedance from two devices were both 0.99 ± 0.01. No statistical significances were found in the parameters investigated. The repeatability (variability) of measures from the same device was comparable. Our EIT device delivers reliable data and might be used for patient measurement in a clinical setting. Nature Publishing Group UK 2021-09-29 /pmc/articles/PMC8481301/ /pubmed/34588556 http://dx.doi.org/10.1038/s41598-021-98793-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Qu, Shuo-Yao Dai, Meng Wu, Shuo Lv, Zhi-Rang Ti, Xin-Yu Fu, Feng System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title | System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title_full | System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title_fullStr | System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title_full_unstemmed | System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title_short | System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title_sort | system introduction and evaluation of the first chinese chest eit device for icu applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8481301/ https://www.ncbi.nlm.nih.gov/pubmed/34588556 http://dx.doi.org/10.1038/s41598-021-98793-0 |
work_keys_str_mv | AT qushuoyao systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications AT daimeng systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications AT wushuo systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications AT lvzhirang systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications AT tixinyu systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications AT fufeng systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications |