Cargando…

Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review

The aim of this review was to assess the evidence for deep learning (DL) analysis of resting electrocardiograms (ECGs) to predict structural cardiac pathologies such as left ventricular (LV) systolic dysfunction, myocardial hypertrophy, and ischaemic heart disease. A systematic literature search was...

Descripción completa

Detalles Bibliográficos
Autores principales: Al Hinai, Ghalib, Jammoul, Samer, Vajihi, Zara, Afilalo, Jonathan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8482047/
https://www.ncbi.nlm.nih.gov/pubmed/34604757
http://dx.doi.org/10.1093/ehjdh/ztab048
_version_ 1784576812691488768
author Al Hinai, Ghalib
Jammoul, Samer
Vajihi, Zara
Afilalo, Jonathan
author_facet Al Hinai, Ghalib
Jammoul, Samer
Vajihi, Zara
Afilalo, Jonathan
author_sort Al Hinai, Ghalib
collection PubMed
description The aim of this review was to assess the evidence for deep learning (DL) analysis of resting electrocardiograms (ECGs) to predict structural cardiac pathologies such as left ventricular (LV) systolic dysfunction, myocardial hypertrophy, and ischaemic heart disease. A systematic literature search was conducted to identify published original articles on end-to-end DL analysis of resting ECG signals for the detection of structural cardiac pathologies. Studies were excluded if the ECG was acquired by ambulatory, stress, intracardiac, or implantable devices, and if the pathology of interest was arrhythmic in nature. After duplicate reviewers screened search results, 12 articles met the inclusion criteria and were included. Three articles used DL to detect LV systolic dysfunction, achieving an area under the curve (AUC) of 0.89–0.93 and an accuracy of 98%. One study used DL to detect LV hypertrophy, achieving an AUC of 0.87 and an accuracy of 87%. Six articles used DL to detect acute myocardial infarction, achieving an AUC of 0.88–1.00 and an accuracy of 83–99.9%. Two articles used DL to detect stable ischaemic heart disease, achieving an accuracy of 95–99.9%. Deep learning models, particularly those that used convolutional neural networks, outperformed rules-based models and other machine learning models. Deep learning is a promising technique to analyse resting ECG signals for the detection of structural cardiac pathologies, which has clinical applicability for more effective screening of asymptomatic populations and expedited diagnostic work-up of symptomatic patients at risk for cardiovascular disease.
format Online
Article
Text
id pubmed-8482047
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-84820472021-09-30 Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review Al Hinai, Ghalib Jammoul, Samer Vajihi, Zara Afilalo, Jonathan Eur Heart J Digit Health Reviews The aim of this review was to assess the evidence for deep learning (DL) analysis of resting electrocardiograms (ECGs) to predict structural cardiac pathologies such as left ventricular (LV) systolic dysfunction, myocardial hypertrophy, and ischaemic heart disease. A systematic literature search was conducted to identify published original articles on end-to-end DL analysis of resting ECG signals for the detection of structural cardiac pathologies. Studies were excluded if the ECG was acquired by ambulatory, stress, intracardiac, or implantable devices, and if the pathology of interest was arrhythmic in nature. After duplicate reviewers screened search results, 12 articles met the inclusion criteria and were included. Three articles used DL to detect LV systolic dysfunction, achieving an area under the curve (AUC) of 0.89–0.93 and an accuracy of 98%. One study used DL to detect LV hypertrophy, achieving an AUC of 0.87 and an accuracy of 87%. Six articles used DL to detect acute myocardial infarction, achieving an AUC of 0.88–1.00 and an accuracy of 83–99.9%. Two articles used DL to detect stable ischaemic heart disease, achieving an accuracy of 95–99.9%. Deep learning models, particularly those that used convolutional neural networks, outperformed rules-based models and other machine learning models. Deep learning is a promising technique to analyse resting ECG signals for the detection of structural cardiac pathologies, which has clinical applicability for more effective screening of asymptomatic populations and expedited diagnostic work-up of symptomatic patients at risk for cardiovascular disease. Oxford University Press 2021-08-07 /pmc/articles/PMC8482047/ /pubmed/34604757 http://dx.doi.org/10.1093/ehjdh/ztab048 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Reviews
Al Hinai, Ghalib
Jammoul, Samer
Vajihi, Zara
Afilalo, Jonathan
Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review
title Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review
title_full Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review
title_fullStr Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review
title_full_unstemmed Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review
title_short Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review
title_sort deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review
topic Reviews
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8482047/
https://www.ncbi.nlm.nih.gov/pubmed/34604757
http://dx.doi.org/10.1093/ehjdh/ztab048
work_keys_str_mv AT alhinaighalib deeplearninganalysisofrestingelectrocardiogramsforthedetectionofmyocardialdysfunctionhypertrophyandischaemiaasystematicreview
AT jammoulsamer deeplearninganalysisofrestingelectrocardiogramsforthedetectionofmyocardialdysfunctionhypertrophyandischaemiaasystematicreview
AT vajihizara deeplearninganalysisofrestingelectrocardiogramsforthedetectionofmyocardialdysfunctionhypertrophyandischaemiaasystematicreview
AT afilalojonathan deeplearninganalysisofrestingelectrocardiogramsforthedetectionofmyocardialdysfunctionhypertrophyandischaemiaasystematicreview