Cargando…
Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review
The aim of this review was to assess the evidence for deep learning (DL) analysis of resting electrocardiograms (ECGs) to predict structural cardiac pathologies such as left ventricular (LV) systolic dysfunction, myocardial hypertrophy, and ischaemic heart disease. A systematic literature search was...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8482047/ https://www.ncbi.nlm.nih.gov/pubmed/34604757 http://dx.doi.org/10.1093/ehjdh/ztab048 |
_version_ | 1784576812691488768 |
---|---|
author | Al Hinai, Ghalib Jammoul, Samer Vajihi, Zara Afilalo, Jonathan |
author_facet | Al Hinai, Ghalib Jammoul, Samer Vajihi, Zara Afilalo, Jonathan |
author_sort | Al Hinai, Ghalib |
collection | PubMed |
description | The aim of this review was to assess the evidence for deep learning (DL) analysis of resting electrocardiograms (ECGs) to predict structural cardiac pathologies such as left ventricular (LV) systolic dysfunction, myocardial hypertrophy, and ischaemic heart disease. A systematic literature search was conducted to identify published original articles on end-to-end DL analysis of resting ECG signals for the detection of structural cardiac pathologies. Studies were excluded if the ECG was acquired by ambulatory, stress, intracardiac, or implantable devices, and if the pathology of interest was arrhythmic in nature. After duplicate reviewers screened search results, 12 articles met the inclusion criteria and were included. Three articles used DL to detect LV systolic dysfunction, achieving an area under the curve (AUC) of 0.89–0.93 and an accuracy of 98%. One study used DL to detect LV hypertrophy, achieving an AUC of 0.87 and an accuracy of 87%. Six articles used DL to detect acute myocardial infarction, achieving an AUC of 0.88–1.00 and an accuracy of 83–99.9%. Two articles used DL to detect stable ischaemic heart disease, achieving an accuracy of 95–99.9%. Deep learning models, particularly those that used convolutional neural networks, outperformed rules-based models and other machine learning models. Deep learning is a promising technique to analyse resting ECG signals for the detection of structural cardiac pathologies, which has clinical applicability for more effective screening of asymptomatic populations and expedited diagnostic work-up of symptomatic patients at risk for cardiovascular disease. |
format | Online Article Text |
id | pubmed-8482047 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-84820472021-09-30 Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review Al Hinai, Ghalib Jammoul, Samer Vajihi, Zara Afilalo, Jonathan Eur Heart J Digit Health Reviews The aim of this review was to assess the evidence for deep learning (DL) analysis of resting electrocardiograms (ECGs) to predict structural cardiac pathologies such as left ventricular (LV) systolic dysfunction, myocardial hypertrophy, and ischaemic heart disease. A systematic literature search was conducted to identify published original articles on end-to-end DL analysis of resting ECG signals for the detection of structural cardiac pathologies. Studies were excluded if the ECG was acquired by ambulatory, stress, intracardiac, or implantable devices, and if the pathology of interest was arrhythmic in nature. After duplicate reviewers screened search results, 12 articles met the inclusion criteria and were included. Three articles used DL to detect LV systolic dysfunction, achieving an area under the curve (AUC) of 0.89–0.93 and an accuracy of 98%. One study used DL to detect LV hypertrophy, achieving an AUC of 0.87 and an accuracy of 87%. Six articles used DL to detect acute myocardial infarction, achieving an AUC of 0.88–1.00 and an accuracy of 83–99.9%. Two articles used DL to detect stable ischaemic heart disease, achieving an accuracy of 95–99.9%. Deep learning models, particularly those that used convolutional neural networks, outperformed rules-based models and other machine learning models. Deep learning is a promising technique to analyse resting ECG signals for the detection of structural cardiac pathologies, which has clinical applicability for more effective screening of asymptomatic populations and expedited diagnostic work-up of symptomatic patients at risk for cardiovascular disease. Oxford University Press 2021-08-07 /pmc/articles/PMC8482047/ /pubmed/34604757 http://dx.doi.org/10.1093/ehjdh/ztab048 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Reviews Al Hinai, Ghalib Jammoul, Samer Vajihi, Zara Afilalo, Jonathan Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review |
title | Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review |
title_full | Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review |
title_fullStr | Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review |
title_full_unstemmed | Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review |
title_short | Deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review |
title_sort | deep learning analysis of resting electrocardiograms for the detection of myocardial dysfunction, hypertrophy, and ischaemia: a systematic review |
topic | Reviews |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8482047/ https://www.ncbi.nlm.nih.gov/pubmed/34604757 http://dx.doi.org/10.1093/ehjdh/ztab048 |
work_keys_str_mv | AT alhinaighalib deeplearninganalysisofrestingelectrocardiogramsforthedetectionofmyocardialdysfunctionhypertrophyandischaemiaasystematicreview AT jammoulsamer deeplearninganalysisofrestingelectrocardiogramsforthedetectionofmyocardialdysfunctionhypertrophyandischaemiaasystematicreview AT vajihizara deeplearninganalysisofrestingelectrocardiogramsforthedetectionofmyocardialdysfunctionhypertrophyandischaemiaasystematicreview AT afilalojonathan deeplearninganalysisofrestingelectrocardiogramsforthedetectionofmyocardialdysfunctionhypertrophyandischaemiaasystematicreview |