Aerosol SARS-CoV-2 in hospitals and long-term care homes during the COVID-19 pandemic

BACKGROUND: Few studies have quantified aerosol concentrations of SARS-CoV-2 in hospitals and long-term care homes, and fewer still have examined samples for viability. This information is needed to clarify transmission risks beyond close contact. METHODS: We deployed particulate air samplers in roo...

Descripción completa

Detalles Bibliográficos
Autores principales: Mallach, Gary, Kasloff, Samantha B., Kovesi, Tom, Kumar, Anand, Kulka, Ryan, Krishnan, Jay, Robert, Benoit, McGuinty, Michaeline, den Otter-Moore, Sophia, Yazji, Bashour, Cutts, Todd
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8483369/
https://www.ncbi.nlm.nih.gov/pubmed/34591919
http://dx.doi.org/10.1371/journal.pone.0258151
Descripción
Sumario:BACKGROUND: Few studies have quantified aerosol concentrations of SARS-CoV-2 in hospitals and long-term care homes, and fewer still have examined samples for viability. This information is needed to clarify transmission risks beyond close contact. METHODS: We deployed particulate air samplers in rooms with COVID-19 positive patients in hospital ward and ICU rooms, rooms in long-term care homes experiencing outbreaks, and a correctional facility experiencing an outbreak. Samplers were placed between 2 and 3 meters from the patient. Aerosol (small liquid particles suspended in air) samples were collected onto gelatin filters by Ultrasonic Personal Air Samplers (UPAS) fitted with <2.5μm (micrometer) and <10 μm size-selective inlets operated for 16 hours (total 1.92m(3)), and with a Coriolis Biosampler over 10 minutes (total 1.5m(3)). Samples were assayed for viable SARS-CoV-2 virus and for the viral genome by multiplex PCR using the E and N protein target sequences. We validated the sampling methods by inoculating gelatin filters with viable vesicular stomatitis virus (VSV), and with three concentrations of viable SARS-CoV-2, operating personal samplers for 16hrs, and quantifying viable virus recovery by TCID(50) assay. RESULTS: In total, 138 samples were collected from 99 rooms. RNA samples were positive in 9.1% (6/66) of samples obtained with the UPAS 2.5μm samplers, 13.5% (7/52) with the UPAS 10μm samplers, and 10.0% (2/20) samples obtained with the Coriolis samplers. Culturable virus was not recovered in any samples. Viral RNA was detected in 15.1% of the rooms sampled. There was no significant difference in viral RNA recovery between the different room locations or samplers. Method development experiments indicated minimal loss of SARS-CoV-2 viability via the personal air sampler operation.