Cargando…

Efficacy of Otomicroscopy Combined with Otoendoscopy Double-Lens Technology-Assisted Tympanic Membrane Repair on Elderly Patients with Chronic Suppurative Otitis Media

OBJECTIVE: To investigate the effect of otomicroscopy combined with otoendoscopy double-lens technology-assisted tympanic membrane repair on elderly patients chronic suppurative otitis media (CSOM). METHODS: 120 elderly CSOM patients from January 2017 to July 2019 were selected and divided into the...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Xin, Wu, Shaohua, Wang, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8483917/
https://www.ncbi.nlm.nih.gov/pubmed/34603469
http://dx.doi.org/10.1155/2021/5164907
_version_ 1784577217567653888
author Cheng, Xin
Wu, Shaohua
Wang, Wei
author_facet Cheng, Xin
Wu, Shaohua
Wang, Wei
author_sort Cheng, Xin
collection PubMed
description OBJECTIVE: To investigate the effect of otomicroscopy combined with otoendoscopy double-lens technology-assisted tympanic membrane repair on elderly patients chronic suppurative otitis media (CSOM). METHODS: 120 elderly CSOM patients from January 2017 to July 2019 were selected and divided into the otomicroscopy group (n = 40), the otoendoscopy group (n = 40), and the double-lens group (n = 40) by the random number method. All patients were treated with tympanic membrane repair. The otomicroscopy group was assisted by otomicroscopy, the otoendoscopy group was assisted by otoendoscopy. and the double-lens group was assisted by otomicroscopy combined with otoendoscopy. The three groups of operations status, clinical efficacy, the incidence of adverse reactions, hearing improvement rate, and satisfaction rate with incision after 6 months were compared. RESULTS: The operation time, intraoperative blood loss, hospitalization time, and VAS score of the otoendoscopy group and the double-lens group were all lower than those of the otoendoscopy group, and the operation time of the double-lens group was lower than that of the otoendoscopy group (P < 0.05). The clinical efficacy of the double-lens group was better than that of the otomicroscopy group and otoendoscopy group (P < 0.05). The adverse reaction rate of the otoendoscopy group and the double-lens group was lower than that of the otomicroscopy group, and the average postoperative air-bone conductance of the double-lens group was lower than that of the otomicroscopy group and the otoendoscopy group, and the hearing improvement rate was higher than that of the otomicroscopy and otoendoscopy groups (P < 0.05). The satisfaction rate with postoperative incision in the otoendoscopy group and double-lens group was higher than that in the otomicroscopy group (P < 0.05). CONCLUSION: The double-lens technology-assisted tympanic membrane repair has an obvious effect on elderly patients with CSOM. Compared with the single-use otomicroscopy, the operation time, intraoperative blood loss, hospitalization time, patient's dry ear condition, degree of surgical pain, clinical efficacy, adverse reaction rate, hearing improvement rate, and patient's incision satisfaction of the double-lens technology are better. Compared with the single-use otoendoscopy, the operation time, clinical efficacy, and hearing improvement rate of the double-lens technology are better.
format Online
Article
Text
id pubmed-8483917
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-84839172021-10-01 Efficacy of Otomicroscopy Combined with Otoendoscopy Double-Lens Technology-Assisted Tympanic Membrane Repair on Elderly Patients with Chronic Suppurative Otitis Media Cheng, Xin Wu, Shaohua Wang, Wei Evid Based Complement Alternat Med Research Article OBJECTIVE: To investigate the effect of otomicroscopy combined with otoendoscopy double-lens technology-assisted tympanic membrane repair on elderly patients chronic suppurative otitis media (CSOM). METHODS: 120 elderly CSOM patients from January 2017 to July 2019 were selected and divided into the otomicroscopy group (n = 40), the otoendoscopy group (n = 40), and the double-lens group (n = 40) by the random number method. All patients were treated with tympanic membrane repair. The otomicroscopy group was assisted by otomicroscopy, the otoendoscopy group was assisted by otoendoscopy. and the double-lens group was assisted by otomicroscopy combined with otoendoscopy. The three groups of operations status, clinical efficacy, the incidence of adverse reactions, hearing improvement rate, and satisfaction rate with incision after 6 months were compared. RESULTS: The operation time, intraoperative blood loss, hospitalization time, and VAS score of the otoendoscopy group and the double-lens group were all lower than those of the otoendoscopy group, and the operation time of the double-lens group was lower than that of the otoendoscopy group (P < 0.05). The clinical efficacy of the double-lens group was better than that of the otomicroscopy group and otoendoscopy group (P < 0.05). The adverse reaction rate of the otoendoscopy group and the double-lens group was lower than that of the otomicroscopy group, and the average postoperative air-bone conductance of the double-lens group was lower than that of the otomicroscopy group and the otoendoscopy group, and the hearing improvement rate was higher than that of the otomicroscopy and otoendoscopy groups (P < 0.05). The satisfaction rate with postoperative incision in the otoendoscopy group and double-lens group was higher than that in the otomicroscopy group (P < 0.05). CONCLUSION: The double-lens technology-assisted tympanic membrane repair has an obvious effect on elderly patients with CSOM. Compared with the single-use otomicroscopy, the operation time, intraoperative blood loss, hospitalization time, patient's dry ear condition, degree of surgical pain, clinical efficacy, adverse reaction rate, hearing improvement rate, and patient's incision satisfaction of the double-lens technology are better. Compared with the single-use otoendoscopy, the operation time, clinical efficacy, and hearing improvement rate of the double-lens technology are better. Hindawi 2021-09-23 /pmc/articles/PMC8483917/ /pubmed/34603469 http://dx.doi.org/10.1155/2021/5164907 Text en Copyright © 2021 Xin Cheng et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Cheng, Xin
Wu, Shaohua
Wang, Wei
Efficacy of Otomicroscopy Combined with Otoendoscopy Double-Lens Technology-Assisted Tympanic Membrane Repair on Elderly Patients with Chronic Suppurative Otitis Media
title Efficacy of Otomicroscopy Combined with Otoendoscopy Double-Lens Technology-Assisted Tympanic Membrane Repair on Elderly Patients with Chronic Suppurative Otitis Media
title_full Efficacy of Otomicroscopy Combined with Otoendoscopy Double-Lens Technology-Assisted Tympanic Membrane Repair on Elderly Patients with Chronic Suppurative Otitis Media
title_fullStr Efficacy of Otomicroscopy Combined with Otoendoscopy Double-Lens Technology-Assisted Tympanic Membrane Repair on Elderly Patients with Chronic Suppurative Otitis Media
title_full_unstemmed Efficacy of Otomicroscopy Combined with Otoendoscopy Double-Lens Technology-Assisted Tympanic Membrane Repair on Elderly Patients with Chronic Suppurative Otitis Media
title_short Efficacy of Otomicroscopy Combined with Otoendoscopy Double-Lens Technology-Assisted Tympanic Membrane Repair on Elderly Patients with Chronic Suppurative Otitis Media
title_sort efficacy of otomicroscopy combined with otoendoscopy double-lens technology-assisted tympanic membrane repair on elderly patients with chronic suppurative otitis media
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8483917/
https://www.ncbi.nlm.nih.gov/pubmed/34603469
http://dx.doi.org/10.1155/2021/5164907
work_keys_str_mv AT chengxin efficacyofotomicroscopycombinedwithotoendoscopydoublelenstechnologyassistedtympanicmembranerepaironelderlypatientswithchronicsuppurativeotitismedia
AT wushaohua efficacyofotomicroscopycombinedwithotoendoscopydoublelenstechnologyassistedtympanicmembranerepaironelderlypatientswithchronicsuppurativeotitismedia
AT wangwei efficacyofotomicroscopycombinedwithotoendoscopydoublelenstechnologyassistedtympanicmembranerepaironelderlypatientswithchronicsuppurativeotitismedia