Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker

Compared with traditional leads, carbon fiber composite leads have a series of advantages such as lightweight, soft texture, and high conductivity. In this experiment, we attempted to improve the existing carbon-fiber-based TTCP metal leads by using carbon-fiber-graphene-woven leads or conductive cl...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Yucheng, Lin, Xuming, Yang, Zhao, Han, Xiaotong, Liu, Meng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8483937/
https://www.ncbi.nlm.nih.gov/pubmed/34603425
http://dx.doi.org/10.1155/2021/7507555
_version_ 1784577222326091776
author Zhou, Yucheng
Lin, Xuming
Yang, Zhao
Han, Xiaotong
Liu, Meng
author_facet Zhou, Yucheng
Lin, Xuming
Yang, Zhao
Han, Xiaotong
Liu, Meng
author_sort Zhou, Yucheng
collection PubMed
description Compared with traditional leads, carbon fiber composite leads have a series of advantages such as lightweight, soft texture, and high conductivity. In this experiment, we attempted to improve the existing carbon-fiber-based TTCP metal leads by using carbon-fiber-graphene-woven leads or conductive cloth, so as to solve a series of defects of TTCP metal leads commonly used in the clinical temporary cardiac pacemaker. We performed a series of measurements, including resistance comparisons and stability checks on the finished product characteristics. The results showed that the resistivity of the whole lead did not change significantly after modification, and the carbon fiber bundle was stable and easily deformed under lower stress to reduce the damage to the myocardium, which had excellent clinical application value.
format Online
Article
Text
id pubmed-8483937
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-84839372021-10-01 Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker Zhou, Yucheng Lin, Xuming Yang, Zhao Han, Xiaotong Liu, Meng Bioinorg Chem Appl Research Article Compared with traditional leads, carbon fiber composite leads have a series of advantages such as lightweight, soft texture, and high conductivity. In this experiment, we attempted to improve the existing carbon-fiber-based TTCP metal leads by using carbon-fiber-graphene-woven leads or conductive cloth, so as to solve a series of defects of TTCP metal leads commonly used in the clinical temporary cardiac pacemaker. We performed a series of measurements, including resistance comparisons and stability checks on the finished product characteristics. The results showed that the resistivity of the whole lead did not change significantly after modification, and the carbon fiber bundle was stable and easily deformed under lower stress to reduce the damage to the myocardium, which had excellent clinical application value. Hindawi 2021-09-23 /pmc/articles/PMC8483937/ /pubmed/34603425 http://dx.doi.org/10.1155/2021/7507555 Text en Copyright © 2021 Yucheng Zhou et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhou, Yucheng
Lin, Xuming
Yang, Zhao
Han, Xiaotong
Liu, Meng
Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker
title Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker
title_full Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker
title_fullStr Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker
title_full_unstemmed Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker
title_short Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker
title_sort fabrication of a lead head made of the carbon-fiber-reinforced composite for the temporary cardiac pacemaker
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8483937/
https://www.ncbi.nlm.nih.gov/pubmed/34603425
http://dx.doi.org/10.1155/2021/7507555
work_keys_str_mv AT zhouyucheng fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker
AT linxuming fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker
AT yangzhao fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker
AT hanxiaotong fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker
AT liumeng fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker