Cargando…
Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker
Compared with traditional leads, carbon fiber composite leads have a series of advantages such as lightweight, soft texture, and high conductivity. In this experiment, we attempted to improve the existing carbon-fiber-based TTCP metal leads by using carbon-fiber-graphene-woven leads or conductive cl...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8483937/ https://www.ncbi.nlm.nih.gov/pubmed/34603425 http://dx.doi.org/10.1155/2021/7507555 |
_version_ | 1784577222326091776 |
---|---|
author | Zhou, Yucheng Lin, Xuming Yang, Zhao Han, Xiaotong Liu, Meng |
author_facet | Zhou, Yucheng Lin, Xuming Yang, Zhao Han, Xiaotong Liu, Meng |
author_sort | Zhou, Yucheng |
collection | PubMed |
description | Compared with traditional leads, carbon fiber composite leads have a series of advantages such as lightweight, soft texture, and high conductivity. In this experiment, we attempted to improve the existing carbon-fiber-based TTCP metal leads by using carbon-fiber-graphene-woven leads or conductive cloth, so as to solve a series of defects of TTCP metal leads commonly used in the clinical temporary cardiac pacemaker. We performed a series of measurements, including resistance comparisons and stability checks on the finished product characteristics. The results showed that the resistivity of the whole lead did not change significantly after modification, and the carbon fiber bundle was stable and easily deformed under lower stress to reduce the damage to the myocardium, which had excellent clinical application value. |
format | Online Article Text |
id | pubmed-8483937 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-84839372021-10-01 Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker Zhou, Yucheng Lin, Xuming Yang, Zhao Han, Xiaotong Liu, Meng Bioinorg Chem Appl Research Article Compared with traditional leads, carbon fiber composite leads have a series of advantages such as lightweight, soft texture, and high conductivity. In this experiment, we attempted to improve the existing carbon-fiber-based TTCP metal leads by using carbon-fiber-graphene-woven leads or conductive cloth, so as to solve a series of defects of TTCP metal leads commonly used in the clinical temporary cardiac pacemaker. We performed a series of measurements, including resistance comparisons and stability checks on the finished product characteristics. The results showed that the resistivity of the whole lead did not change significantly after modification, and the carbon fiber bundle was stable and easily deformed under lower stress to reduce the damage to the myocardium, which had excellent clinical application value. Hindawi 2021-09-23 /pmc/articles/PMC8483937/ /pubmed/34603425 http://dx.doi.org/10.1155/2021/7507555 Text en Copyright © 2021 Yucheng Zhou et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhou, Yucheng Lin, Xuming Yang, Zhao Han, Xiaotong Liu, Meng Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title | Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title_full | Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title_fullStr | Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title_full_unstemmed | Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title_short | Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title_sort | fabrication of a lead head made of the carbon-fiber-reinforced composite for the temporary cardiac pacemaker |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8483937/ https://www.ncbi.nlm.nih.gov/pubmed/34603425 http://dx.doi.org/10.1155/2021/7507555 |
work_keys_str_mv | AT zhouyucheng fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker AT linxuming fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker AT yangzhao fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker AT hanxiaotong fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker AT liumeng fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker |