Cargando…

Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use

AIMS: Catheter ablation (CA) is the choice therapy of cavotricuspid isthmus (CTI) atrial flutter. The aim of this study was to describe our approach to improve the CTI ablation using a zero‐fluoroscopy (ZF). The procedural difficulties could be related to anatomical characteristics of the CTI. METHO...

Descripción completa

Detalles Bibliográficos
Autores principales: Santoro, Amato, Baiocchi, Claudia, Sisti, Nicolò, Zacà, Valerio, Pondrelli, Carlo Renato, Falciani, Francesca, Lamberti, Filippo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8485825/
https://www.ncbi.nlm.nih.gov/pubmed/34621430
http://dx.doi.org/10.1002/joa3.12596
_version_ 1784577611751489536
author Santoro, Amato
Baiocchi, Claudia
Sisti, Nicolò
Zacà, Valerio
Pondrelli, Carlo Renato
Falciani, Francesca
Lamberti, Filippo
author_facet Santoro, Amato
Baiocchi, Claudia
Sisti, Nicolò
Zacà, Valerio
Pondrelli, Carlo Renato
Falciani, Francesca
Lamberti, Filippo
author_sort Santoro, Amato
collection PubMed
description AIMS: Catheter ablation (CA) is the choice therapy of cavotricuspid isthmus (CTI) atrial flutter. The aim of this study was to describe our approach to improve the CTI ablation using a zero‐fluoroscopy (ZF). The procedural difficulties could be related to anatomical characteristics of the CTI. METHODS: One hundred eighty‐eight patients that performed CA of CTI were retrospectively and consecutively evaluated between 2017 and 2019. The studied population was divided into two groups. Eighty‐eight patients who were undergone CA using ablation catheter without shaft visualization catheter (NSV) were Group 1. One hundred patients were undergone CA using ablation catheter with a shaft visualization (SV); they were Group 2. The catheter was looped at the Eustachian ridge after 200 seconds of radiofrequencies (RF) without elimination of local electrogram. RESULTS: A conduction line block of CTI was obtained in all patients of Group 2 using a ZF approach. In 16 patients of Group 1, the catheter inversion was obtained using fluoroscopy to avoid damages during its loop. In Group 2, a complete CTI block was obtained with a catheter inversion approach in ten patients without fluoroscopy, visualizing the shaft and the tip of the ablation catheter on the electroanatomic (EAM) map. In the overall population studied the use of SV had a linear correlation with the ZF approach (r = .629; P < .001). The duration of RF was lower in Group 2 than in Group 1 (Group 1: 27.8 ± 6.3 vs Group 2: 15.6 ± 7.2 minutes; P < .01). The procedure time between two groups was lower in Group 2 than in Group 1 (Group 1: 58.4 ± 22.4 vs Group 2: 42.2 ± 15.7 minutes; P < .01). No differences between two groups were documented regarding success and complications. CONCLUSIONS: The visualization of the shaft's catheter on the EAM permitted the catheter inversion safely in order to overcome some complex CTI anatomy and obtain bidirectional block. The SV reduced procedure time, RF applications and fluoroscopy exposition during CTI ablation.
format Online
Article
Text
id pubmed-8485825
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-84858252021-10-06 Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use Santoro, Amato Baiocchi, Claudia Sisti, Nicolò Zacà, Valerio Pondrelli, Carlo Renato Falciani, Francesca Lamberti, Filippo J Arrhythm Original Articles AIMS: Catheter ablation (CA) is the choice therapy of cavotricuspid isthmus (CTI) atrial flutter. The aim of this study was to describe our approach to improve the CTI ablation using a zero‐fluoroscopy (ZF). The procedural difficulties could be related to anatomical characteristics of the CTI. METHODS: One hundred eighty‐eight patients that performed CA of CTI were retrospectively and consecutively evaluated between 2017 and 2019. The studied population was divided into two groups. Eighty‐eight patients who were undergone CA using ablation catheter without shaft visualization catheter (NSV) were Group 1. One hundred patients were undergone CA using ablation catheter with a shaft visualization (SV); they were Group 2. The catheter was looped at the Eustachian ridge after 200 seconds of radiofrequencies (RF) without elimination of local electrogram. RESULTS: A conduction line block of CTI was obtained in all patients of Group 2 using a ZF approach. In 16 patients of Group 1, the catheter inversion was obtained using fluoroscopy to avoid damages during its loop. In Group 2, a complete CTI block was obtained with a catheter inversion approach in ten patients without fluoroscopy, visualizing the shaft and the tip of the ablation catheter on the electroanatomic (EAM) map. In the overall population studied the use of SV had a linear correlation with the ZF approach (r = .629; P < .001). The duration of RF was lower in Group 2 than in Group 1 (Group 1: 27.8 ± 6.3 vs Group 2: 15.6 ± 7.2 minutes; P < .01). The procedure time between two groups was lower in Group 2 than in Group 1 (Group 1: 58.4 ± 22.4 vs Group 2: 42.2 ± 15.7 minutes; P < .01). No differences between two groups were documented regarding success and complications. CONCLUSIONS: The visualization of the shaft's catheter on the EAM permitted the catheter inversion safely in order to overcome some complex CTI anatomy and obtain bidirectional block. The SV reduced procedure time, RF applications and fluoroscopy exposition during CTI ablation. John Wiley and Sons Inc. 2021-07-11 /pmc/articles/PMC8485825/ /pubmed/34621430 http://dx.doi.org/10.1002/joa3.12596 Text en © 2021 The Authors. Journal of Arrhythmia published by John Wiley & Sons Australia, Ltd on behalf of Japanese Heart Rhythm Society https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Santoro, Amato
Baiocchi, Claudia
Sisti, Nicolò
Zacà, Valerio
Pondrelli, Carlo Renato
Falciani, Francesca
Lamberti, Filippo
Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use
title Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use
title_full Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use
title_fullStr Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use
title_full_unstemmed Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use
title_short Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use
title_sort catheter inversion during cavotricuspid isthmus catheter ablation: the new shaft visualization catheter reduces fluoroscopy use
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8485825/
https://www.ncbi.nlm.nih.gov/pubmed/34621430
http://dx.doi.org/10.1002/joa3.12596
work_keys_str_mv AT santoroamato catheterinversionduringcavotricuspidisthmuscatheterablationthenewshaftvisualizationcatheterreducesfluoroscopyuse
AT baiocchiclaudia catheterinversionduringcavotricuspidisthmuscatheterablationthenewshaftvisualizationcatheterreducesfluoroscopyuse
AT sistinicolo catheterinversionduringcavotricuspidisthmuscatheterablationthenewshaftvisualizationcatheterreducesfluoroscopyuse
AT zacavalerio catheterinversionduringcavotricuspidisthmuscatheterablationthenewshaftvisualizationcatheterreducesfluoroscopyuse
AT pondrellicarlorenato catheterinversionduringcavotricuspidisthmuscatheterablationthenewshaftvisualizationcatheterreducesfluoroscopyuse
AT falcianifrancesca catheterinversionduringcavotricuspidisthmuscatheterablationthenewshaftvisualizationcatheterreducesfluoroscopyuse
AT lambertifilippo catheterinversionduringcavotricuspidisthmuscatheterablationthenewshaftvisualizationcatheterreducesfluoroscopyuse