The Functional Assessment of Balance in Concussion (FAB-C) Battery

BACKGROUND: There is no clinical tool that assesses multiple components of postural control potentially impacted by sport-related concussion (SRC). OBJECTIVE: To develop and assess the feasibility and construct validity of the Functional Assessment of Balance in Concussion (FAB-C) battery. STUDY DES...

Descripción completa

Detalles Bibliográficos
Autores principales: Manaseer, Thaer, Whittaker, Jackie L., Isaac, Codi, Schneider, Kathryn J., Gross, Douglas P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: NASMI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8486398/
https://www.ncbi.nlm.nih.gov/pubmed/34631245
http://dx.doi.org/10.26603/001c.28157
_version_ 1784577730893840384
author Manaseer, Thaer
Whittaker, Jackie L.
Isaac, Codi
Schneider, Kathryn J.
Gross, Douglas P.
author_facet Manaseer, Thaer
Whittaker, Jackie L.
Isaac, Codi
Schneider, Kathryn J.
Gross, Douglas P.
author_sort Manaseer, Thaer
collection PubMed
description BACKGROUND: There is no clinical tool that assesses multiple components of postural control potentially impacted by sport-related concussion (SRC). OBJECTIVE: To develop and assess the feasibility and construct validity of the Functional Assessment of Balance in Concussion (FAB-C) battery. STUDY DESIGN: Cross-sectional study. METHODS: Tests for inclusion in the FAB-C battery were identified through a search of the literature. The feasibility and construct validity of the battery was assessed with a convenience sample of active individuals (13–24 years) with and without a SRC. Feasibility outcomes included battery completion (yes/no), number of adverse events, time to administer (minutes) and cost of the battery (Canadian Dollars). Construct validity was assessed by examining correlations between tests included in the battery, and describing differences [mean (standard deviation), median (range) or proportion] in outcomes between uninjured participants and participants with SRC. RESULTS: Seven tests were included in the FAB-C battery. All 40 uninjured participants [12 female; median age 17 years] completed the FAB-C assessment compared to 86% of seven participants with SRC [1 female; median age 17]. No participants demonstrated adverse effects. The median administration time of the battery was 49 minutes (range 44-60). The cost of the battery was low (~$100 Canadian Dollars). Limited correlations (r<0.7) between tests in the battery were observed. A greater percentage of uninjured participants (52% to 82%) passed individual tests in the battery compared to participants with SRC (17% to 66%). CONCLUSION: Although promising, the FAB-C battery requires further evaluation before adoption for widespread clinical use. LEVEL OF EVIDENCE: Level 3b
format Online
Article
Text
id pubmed-8486398
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher NASMI
record_format MEDLINE/PubMed
spelling pubmed-84863982021-10-08 The Functional Assessment of Balance in Concussion (FAB-C) Battery Manaseer, Thaer Whittaker, Jackie L. Isaac, Codi Schneider, Kathryn J. Gross, Douglas P. Int J Sports Phys Ther Original Research BACKGROUND: There is no clinical tool that assesses multiple components of postural control potentially impacted by sport-related concussion (SRC). OBJECTIVE: To develop and assess the feasibility and construct validity of the Functional Assessment of Balance in Concussion (FAB-C) battery. STUDY DESIGN: Cross-sectional study. METHODS: Tests for inclusion in the FAB-C battery were identified through a search of the literature. The feasibility and construct validity of the battery was assessed with a convenience sample of active individuals (13–24 years) with and without a SRC. Feasibility outcomes included battery completion (yes/no), number of adverse events, time to administer (minutes) and cost of the battery (Canadian Dollars). Construct validity was assessed by examining correlations between tests included in the battery, and describing differences [mean (standard deviation), median (range) or proportion] in outcomes between uninjured participants and participants with SRC. RESULTS: Seven tests were included in the FAB-C battery. All 40 uninjured participants [12 female; median age 17 years] completed the FAB-C assessment compared to 86% of seven participants with SRC [1 female; median age 17]. No participants demonstrated adverse effects. The median administration time of the battery was 49 minutes (range 44-60). The cost of the battery was low (~$100 Canadian Dollars). Limited correlations (r<0.7) between tests in the battery were observed. A greater percentage of uninjured participants (52% to 82%) passed individual tests in the battery compared to participants with SRC (17% to 66%). CONCLUSION: Although promising, the FAB-C battery requires further evaluation before adoption for widespread clinical use. LEVEL OF EVIDENCE: Level 3b NASMI 2021-09-01 /pmc/articles/PMC8486398/ /pubmed/34631245 http://dx.doi.org/10.26603/001c.28157 Text en https://creativecommons.org/licenses/by-nc-sa/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike License (4.0) (https://creativecommons.org/licenses/by-nc-sa/4.0/) which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited. If you remix, transform, or build upon this work, you must distribute your contributions under the same license as the original.
spellingShingle Original Research
Manaseer, Thaer
Whittaker, Jackie L.
Isaac, Codi
Schneider, Kathryn J.
Gross, Douglas P.
The Functional Assessment of Balance in Concussion (FAB-C) Battery
title The Functional Assessment of Balance in Concussion (FAB-C) Battery
title_full The Functional Assessment of Balance in Concussion (FAB-C) Battery
title_fullStr The Functional Assessment of Balance in Concussion (FAB-C) Battery
title_full_unstemmed The Functional Assessment of Balance in Concussion (FAB-C) Battery
title_short The Functional Assessment of Balance in Concussion (FAB-C) Battery
title_sort functional assessment of balance in concussion (fab-c) battery
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8486398/
https://www.ncbi.nlm.nih.gov/pubmed/34631245
http://dx.doi.org/10.26603/001c.28157
work_keys_str_mv AT manaseerthaer thefunctionalassessmentofbalanceinconcussionfabcbattery
AT whittakerjackiel thefunctionalassessmentofbalanceinconcussionfabcbattery
AT isaaccodi thefunctionalassessmentofbalanceinconcussionfabcbattery
AT schneiderkathrynj thefunctionalassessmentofbalanceinconcussionfabcbattery
AT grossdouglasp thefunctionalassessmentofbalanceinconcussionfabcbattery
AT manaseerthaer functionalassessmentofbalanceinconcussionfabcbattery
AT whittakerjackiel functionalassessmentofbalanceinconcussionfabcbattery
AT isaaccodi functionalassessmentofbalanceinconcussionfabcbattery
AT schneiderkathrynj functionalassessmentofbalanceinconcussionfabcbattery
AT grossdouglasp functionalassessmentofbalanceinconcussionfabcbattery