Cargando…

Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention

Introduction: Management of chronic infection following total knee arthroplasty (TKA) is challenging. Rotating hinged prostheses are often required in this setting due to severe bone loss, ligamentous insufficiency, or a combination of the two. The nature of the mechanical and septic complications o...

Descripción completa

Detalles Bibliográficos
Autores principales: Bourbotte-Salmon, Florian, Ferry, Tristan, Cardinale, Mickaël, Servien, Elvire, Rongieras, Frédéric, Fessy, Michel-Henry, Bertani, Antoine, Laurent, Frédéric, Buffe-Lidove, Margaux, Batailler, Cécile, Lustig, Sébastien
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8488173/
https://www.ncbi.nlm.nih.gov/pubmed/34616767
http://dx.doi.org/10.3389/fsurg.2021.551814
_version_ 1784578102154756096
author Bourbotte-Salmon, Florian
Ferry, Tristan
Cardinale, Mickaël
Servien, Elvire
Rongieras, Frédéric
Fessy, Michel-Henry
Bertani, Antoine
Laurent, Frédéric
Buffe-Lidove, Margaux
Batailler, Cécile
Lustig, Sébastien
author_facet Bourbotte-Salmon, Florian
Ferry, Tristan
Cardinale, Mickaël
Servien, Elvire
Rongieras, Frédéric
Fessy, Michel-Henry
Bertani, Antoine
Laurent, Frédéric
Buffe-Lidove, Margaux
Batailler, Cécile
Lustig, Sébastien
author_sort Bourbotte-Salmon, Florian
collection PubMed
description Introduction: Management of chronic infection following total knee arthroplasty (TKA) is challenging. Rotating hinged prostheses are often required in this setting due to severe bone loss, ligamentous insufficiency, or a combination of the two. The nature of the mechanical and septic complications occurring in this setting has not been well-described. The aim of this study was to evaluate patient outcomes using a hinge knee prosthesis for prosthetic knee infections and to investigate risk factors for implant removal. Methods: This was a retrospective cohort study that included all patients treated in our tertiary level referral center between January 2009 and December 2016 for prosthetic knee infection with a hinge knee prosthesis. Only patients with a minimum 2-year of follow-up were included. Functional evaluation was performed using international knee society (IKS) “Knee” and “Function” scores. Survival analysis comparing implant removal risks for mechanical and septic causes was performed using Cox univariate analysis and Kaplan-Meier curves. Risk factors for implant removal and septic failure were assessed. Results: Forty-six knees were eligible for inclusion. The majority of patients had satisfactory functional outcomes as determined by mean IKS scores (mean knee score: 70.53, mean function score: 46.53 points, and mean knee flexion: 88.75°). The 2-year implant survival rate was 89% but dropped to 65% at 7 years follow-up. The risk of failure (i.e., implant removal) was higher for septic etiology compared to mechanical causes. Patients with American society of anesthesiologists (ASA) score>1, immunosuppression, or with peripheral arterial diseases had a higher risk for septic failure. Patients with acute infection according to the Tsukayamaclassification had a higher risk of failure. Of the 46 patients included, 19 (41.3%) had atleast one infectious event on the surgical knee and most of these were superinfections (14/19) with new pathogens isolated. Among pathogens responsible for superinfections (i) cefazolin and gentamicin were both active in six of the cases but failed to prevent the superinfection; (ii) cefazolin and/or gentamicin were not active in eight patients, leading to alternative systemic and/or local antimicrobial prophylaxis consideration. Conclusions: Patients with chronic total knee arthroplasty (TKA) infection, requiring revision using rotating hinge implant, had good functional outcomes but experienced a high rate of septic failure, mostly due to bacterial superinfection. These patients may need optimal antimicrobial systemic prophylaxis and innovative approaches to reduce the rate of superinfection.
format Online
Article
Text
id pubmed-8488173
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-84881732021-10-05 Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention Bourbotte-Salmon, Florian Ferry, Tristan Cardinale, Mickaël Servien, Elvire Rongieras, Frédéric Fessy, Michel-Henry Bertani, Antoine Laurent, Frédéric Buffe-Lidove, Margaux Batailler, Cécile Lustig, Sébastien Front Surg Surgery Introduction: Management of chronic infection following total knee arthroplasty (TKA) is challenging. Rotating hinged prostheses are often required in this setting due to severe bone loss, ligamentous insufficiency, or a combination of the two. The nature of the mechanical and septic complications occurring in this setting has not been well-described. The aim of this study was to evaluate patient outcomes using a hinge knee prosthesis for prosthetic knee infections and to investigate risk factors for implant removal. Methods: This was a retrospective cohort study that included all patients treated in our tertiary level referral center between January 2009 and December 2016 for prosthetic knee infection with a hinge knee prosthesis. Only patients with a minimum 2-year of follow-up were included. Functional evaluation was performed using international knee society (IKS) “Knee” and “Function” scores. Survival analysis comparing implant removal risks for mechanical and septic causes was performed using Cox univariate analysis and Kaplan-Meier curves. Risk factors for implant removal and septic failure were assessed. Results: Forty-six knees were eligible for inclusion. The majority of patients had satisfactory functional outcomes as determined by mean IKS scores (mean knee score: 70.53, mean function score: 46.53 points, and mean knee flexion: 88.75°). The 2-year implant survival rate was 89% but dropped to 65% at 7 years follow-up. The risk of failure (i.e., implant removal) was higher for septic etiology compared to mechanical causes. Patients with American society of anesthesiologists (ASA) score>1, immunosuppression, or with peripheral arterial diseases had a higher risk for septic failure. Patients with acute infection according to the Tsukayamaclassification had a higher risk of failure. Of the 46 patients included, 19 (41.3%) had atleast one infectious event on the surgical knee and most of these were superinfections (14/19) with new pathogens isolated. Among pathogens responsible for superinfections (i) cefazolin and gentamicin were both active in six of the cases but failed to prevent the superinfection; (ii) cefazolin and/or gentamicin were not active in eight patients, leading to alternative systemic and/or local antimicrobial prophylaxis consideration. Conclusions: Patients with chronic total knee arthroplasty (TKA) infection, requiring revision using rotating hinge implant, had good functional outcomes but experienced a high rate of septic failure, mostly due to bacterial superinfection. These patients may need optimal antimicrobial systemic prophylaxis and innovative approaches to reduce the rate of superinfection. Frontiers Media S.A. 2021-09-20 /pmc/articles/PMC8488173/ /pubmed/34616767 http://dx.doi.org/10.3389/fsurg.2021.551814 Text en Copyright © 2021 Bourbotte-Salmon, Ferry, Cardinale, Servien, Rongieras, Fessy, Bertani, Laurent, Buffe-Lidove, Batailler, Lustig and The Lyon Bone and Joint Infections Study Group. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Bourbotte-Salmon, Florian
Ferry, Tristan
Cardinale, Mickaël
Servien, Elvire
Rongieras, Frédéric
Fessy, Michel-Henry
Bertani, Antoine
Laurent, Frédéric
Buffe-Lidove, Margaux
Batailler, Cécile
Lustig, Sébastien
Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention
title Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention
title_full Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention
title_fullStr Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention
title_full_unstemmed Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention
title_short Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention
title_sort rotating hinge knee arthroplasty for revision prosthetic-knee infection: good functional outcomes but a crucial need for superinfection prevention
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8488173/
https://www.ncbi.nlm.nih.gov/pubmed/34616767
http://dx.doi.org/10.3389/fsurg.2021.551814
work_keys_str_mv AT bourbottesalmonflorian rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT ferrytristan rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT cardinalemickael rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT servienelvire rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT rongierasfrederic rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT fessymichelhenry rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT bertaniantoine rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT laurentfrederic rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT buffelidovemargaux rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT bataillercecile rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT lustigsebastien rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention
AT rotatinghingekneearthroplastyforrevisionprosthetickneeinfectiongoodfunctionaloutcomesbutacrucialneedforsuperinfectionprevention