Cargando…

Left atrial conduit function: A short review

Three‐dimensional echocardiography can elucidate the phasic functions of the left atrium if a simultaneous acquisition of a pyramidal full‐volume dataset, as gathered from the apical window and containing the entire left atrial and left ventricular cardiac sections, is obtained. Hence, conduit can b...

Descripción completa

Detalles Bibliográficos
Autor principal: Marino, Paolo N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8488566/
https://www.ncbi.nlm.nih.gov/pubmed/34605214
http://dx.doi.org/10.14814/phy2.15053
_version_ 1784578197378039808
author Marino, Paolo N.
author_facet Marino, Paolo N.
author_sort Marino, Paolo N.
collection PubMed
description Three‐dimensional echocardiography can elucidate the phasic functions of the left atrium if a simultaneous acquisition of a pyramidal full‐volume dataset, as gathered from the apical window and containing the entire left atrial and left ventricular cardiac sections, is obtained. Hence, conduit can be quantified as the integral of net, diastolic, instantaneous difference between synchronized atrial and ventricular volume curves, beginning at minimum ventricular cavity volume and ending just before atrial contraction. Increased conduit can reflect increased downstream suction, as conduit would track the apex‐to‐base intracavitary pressure gradient existing, in early diastole, within the single chamber formed by the atrium and the ventricle, when the mitral valve is open. Such a gradient increases in response to adrenergic stimulation or during exercise and mediates an increment in passive flow during early diastole, with the ventricle being filled from the atrial reservoir and, simultaneously, from blood drawn from the pulmonary veins. In this context conduit, and even more conduit flow rate, expressed in ml/sec, can be viewed as an indirect marker of left ventricular relaxation. It is well known, however, that a large amount of conduit (in relative terms) is also supposed to contribute to LV stroke volume in conditions of increased resistance to LV filling, when diastolic function significantly worsens. Stiffening of the atrio‐ventricular complex implies increments in LA pressure more pronounced in late systole, causing markedly elevated “v” waves, independently of the presence of mitral insufficiency. The combination of increased atrio‐ventricular stiffness and conduit flow is associated with an elevation of the right ventricular pulsatile relative to resistive load that negatively impacts on exercise capacity and survival in these patients. Atrial conduit is an “intriguing” parameter that conveys a noninvasive picture of the complex atrioventricular coupling condition in diastole and its backward effects on the right side of the heart and the pulmonary circulation. Given the easiness associated with its correctly performed quantification in the imaging laboratory, I am sure that conduit will survive the competitive access to the list of valuable parameters capable of deciphering, although not necessarily simplifying, the complex diastolic scenario in health and disease.
format Online
Article
Text
id pubmed-8488566
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-84885662021-10-08 Left atrial conduit function: A short review Marino, Paolo N. Physiol Rep Reviews Three‐dimensional echocardiography can elucidate the phasic functions of the left atrium if a simultaneous acquisition of a pyramidal full‐volume dataset, as gathered from the apical window and containing the entire left atrial and left ventricular cardiac sections, is obtained. Hence, conduit can be quantified as the integral of net, diastolic, instantaneous difference between synchronized atrial and ventricular volume curves, beginning at minimum ventricular cavity volume and ending just before atrial contraction. Increased conduit can reflect increased downstream suction, as conduit would track the apex‐to‐base intracavitary pressure gradient existing, in early diastole, within the single chamber formed by the atrium and the ventricle, when the mitral valve is open. Such a gradient increases in response to adrenergic stimulation or during exercise and mediates an increment in passive flow during early diastole, with the ventricle being filled from the atrial reservoir and, simultaneously, from blood drawn from the pulmonary veins. In this context conduit, and even more conduit flow rate, expressed in ml/sec, can be viewed as an indirect marker of left ventricular relaxation. It is well known, however, that a large amount of conduit (in relative terms) is also supposed to contribute to LV stroke volume in conditions of increased resistance to LV filling, when diastolic function significantly worsens. Stiffening of the atrio‐ventricular complex implies increments in LA pressure more pronounced in late systole, causing markedly elevated “v” waves, independently of the presence of mitral insufficiency. The combination of increased atrio‐ventricular stiffness and conduit flow is associated with an elevation of the right ventricular pulsatile relative to resistive load that negatively impacts on exercise capacity and survival in these patients. Atrial conduit is an “intriguing” parameter that conveys a noninvasive picture of the complex atrioventricular coupling condition in diastole and its backward effects on the right side of the heart and the pulmonary circulation. Given the easiness associated with its correctly performed quantification in the imaging laboratory, I am sure that conduit will survive the competitive access to the list of valuable parameters capable of deciphering, although not necessarily simplifying, the complex diastolic scenario in health and disease. John Wiley and Sons Inc. 2021-10-04 /pmc/articles/PMC8488566/ /pubmed/34605214 http://dx.doi.org/10.14814/phy2.15053 Text en © 2021 The Authors. Physiological Reports published by Wiley Periodicals LLC on behalf of The Physiological Society and the American Physiological Society https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Reviews
Marino, Paolo N.
Left atrial conduit function: A short review
title Left atrial conduit function: A short review
title_full Left atrial conduit function: A short review
title_fullStr Left atrial conduit function: A short review
title_full_unstemmed Left atrial conduit function: A short review
title_short Left atrial conduit function: A short review
title_sort left atrial conduit function: a short review
topic Reviews
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8488566/
https://www.ncbi.nlm.nih.gov/pubmed/34605214
http://dx.doi.org/10.14814/phy2.15053
work_keys_str_mv AT marinopaolon leftatrialconduitfunctionashortreview