Cargando…

Evaluation of Triage Tests When Existing Test Capacity Is Constrained: Application to Rapid Diagnostic Testing in COVID-19

OBJECTIVES: A triage test is used to determine which patients will undergo an existing or “reference” test. This article explores the potential value of using triage tests before reference tests when the capacity of the reference test is constrained. METHODS: We developed a simple model with inputs:...

Descripción completa

Detalles Bibliográficos
Autores principales: Bouttell, Janet, Hawkins, Neil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8488642/
https://www.ncbi.nlm.nih.gov/pubmed/34009068
http://dx.doi.org/10.1177/0272989X211014114
_version_ 1784578208287424512
author Bouttell, Janet
Hawkins, Neil
author_facet Bouttell, Janet
Hawkins, Neil
author_sort Bouttell, Janet
collection PubMed
description OBJECTIVES: A triage test is used to determine which patients will undergo an existing or “reference” test. This article explores the potential value of using triage tests before reference tests when the capacity of the reference test is constrained. METHODS: We developed a simple model with inputs: prevalence, sensitivity, specificity, and reference test capacity. We included a case study of rapid diagnostic tests for SARS-CoV-2 antigens used as triage tests before a reference polymerase chain reaction test. Performance data were obtained from an evaluation performed by an academic center on 425 samples from testing centers in the United Kingdom and Germany. RESULTS: When reference test capacity is constrained, the use of a triage test leads to a relative expansion of the population tested and cases identified; both are higher with a high-specificity triage test. When reference test capacity is not constrained, the potential advantages of introducing a triage test can be assessed using a standard cost-utility framework, balancing the utility of the reduction in the number of reference tests required against the disutility of missed cases associated with the use of a lower-sensitivity triage test. In the constrained case, the advantage of a triage testing strategy in terms of population covered and cases identified is reduced as the prevalence increases. In the unconstrained case, the reduction in reference tests required is reduced and the number of cases missed increase as the prevalence rises. CONCLUSION: When the availability of the reference test is constrained, tests added in a triage position do not need high levels of accuracy to increase the number of cases diagnosed. This has implications in many disease areas, including COVID-19.
format Online
Article
Text
id pubmed-8488642
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-84886422021-10-05 Evaluation of Triage Tests When Existing Test Capacity Is Constrained: Application to Rapid Diagnostic Testing in COVID-19 Bouttell, Janet Hawkins, Neil Med Decis Making Original Research Articles OBJECTIVES: A triage test is used to determine which patients will undergo an existing or “reference” test. This article explores the potential value of using triage tests before reference tests when the capacity of the reference test is constrained. METHODS: We developed a simple model with inputs: prevalence, sensitivity, specificity, and reference test capacity. We included a case study of rapid diagnostic tests for SARS-CoV-2 antigens used as triage tests before a reference polymerase chain reaction test. Performance data were obtained from an evaluation performed by an academic center on 425 samples from testing centers in the United Kingdom and Germany. RESULTS: When reference test capacity is constrained, the use of a triage test leads to a relative expansion of the population tested and cases identified; both are higher with a high-specificity triage test. When reference test capacity is not constrained, the potential advantages of introducing a triage test can be assessed using a standard cost-utility framework, balancing the utility of the reduction in the number of reference tests required against the disutility of missed cases associated with the use of a lower-sensitivity triage test. In the constrained case, the advantage of a triage testing strategy in terms of population covered and cases identified is reduced as the prevalence increases. In the unconstrained case, the reduction in reference tests required is reduced and the number of cases missed increase as the prevalence rises. CONCLUSION: When the availability of the reference test is constrained, tests added in a triage position do not need high levels of accuracy to increase the number of cases diagnosed. This has implications in many disease areas, including COVID-19. SAGE Publications 2021-05-19 2021-11 /pmc/articles/PMC8488642/ /pubmed/34009068 http://dx.doi.org/10.1177/0272989X211014114 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research Articles
Bouttell, Janet
Hawkins, Neil
Evaluation of Triage Tests When Existing Test Capacity Is Constrained: Application to Rapid Diagnostic Testing in COVID-19
title Evaluation of Triage Tests When Existing Test Capacity Is Constrained: Application to Rapid Diagnostic Testing in COVID-19
title_full Evaluation of Triage Tests When Existing Test Capacity Is Constrained: Application to Rapid Diagnostic Testing in COVID-19
title_fullStr Evaluation of Triage Tests When Existing Test Capacity Is Constrained: Application to Rapid Diagnostic Testing in COVID-19
title_full_unstemmed Evaluation of Triage Tests When Existing Test Capacity Is Constrained: Application to Rapid Diagnostic Testing in COVID-19
title_short Evaluation of Triage Tests When Existing Test Capacity Is Constrained: Application to Rapid Diagnostic Testing in COVID-19
title_sort evaluation of triage tests when existing test capacity is constrained: application to rapid diagnostic testing in covid-19
topic Original Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8488642/
https://www.ncbi.nlm.nih.gov/pubmed/34009068
http://dx.doi.org/10.1177/0272989X211014114
work_keys_str_mv AT bouttelljanet evaluationoftriagetestswhenexistingtestcapacityisconstrainedapplicationtorapiddiagnostictestingincovid19
AT hawkinsneil evaluationoftriagetestswhenexistingtestcapacityisconstrainedapplicationtorapiddiagnostictestingincovid19