The effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice

Cadmium Zinc Telluride (CZT) crystal-based myocardial perfusion imaging (MPI) cameras have increased count sensitivity compared to Anger cameras and can be used to lower either the injected activity or the image acquisition time. Institutions adopting CZT cameras need to decide whether to lower the...

Descripción completa

Detalles Bibliográficos
Autores principales: Prasad, Kalpna, Adams, Chad C., Quang, Eiping, Taylor, Justin, Stocker, Derek J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8488894/
https://www.ncbi.nlm.nih.gov/pubmed/34703392
http://dx.doi.org/10.4103/wjnm.WJNM_123_20
_version_ 1784578242444787712
author Prasad, Kalpna
Adams, Chad C.
Quang, Eiping
Taylor, Justin
Stocker, Derek J.
author_facet Prasad, Kalpna
Adams, Chad C.
Quang, Eiping
Taylor, Justin
Stocker, Derek J.
author_sort Prasad, Kalpna
collection PubMed
description Cadmium Zinc Telluride (CZT) crystal-based myocardial perfusion imaging (MPI) cameras have increased count sensitivity compared to Anger cameras and can be used to lower either the injected activity or the image acquisition time. Institutions adopting CZT cameras need to decide whether to lower the injected activity or imaging time or attempt to lower both with a compromise. The aim of our study was to compare the scan time required to obtain similar count images using high activity protocol (HAP) versus low activity protocol (LAP) stratified by body mass index (BMI) and assess the impact on effective dose and our clinic workflow. Using a CZT camera, a cohort of 100 consecutive clinical patients imaged with LAP rest-stress MPI with approximately 185 MBq and 555 MBq activity was retrospectively compared to a similar cohort of 100 consecutive clinical patients imaged with HAP rest-stress MPI using approximately 370 MBq and 1110 MBq. Administered activity and BMI both had a statistically significant effect on scan time and radiation effective dose. LAP scans took an average of 9 min longer than HAP scans overall, P < 0.0001 and larger BMIs took longer than smaller BMIs, P < 0.0001. In addition, scan times were longer in men than women, P = 0.007. Effective dose was inversely proportional to BMI with an overall decrease of approximately 50% comparing LAP to HAP. For the same CZT camera, the LAP increased scan time while lowering the radiation effective dose when compared to HAP. The increase in scan time increased proportionally to BMI. The effective dose was inversely proportional to BMI. This increase in time did not have a significant impact on our local workflow, but its implications should be considered in the setting of LAP implementation, especially in obese or high patient volume practices.
format Online
Article
Text
id pubmed-8488894
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-84888942021-10-25 The effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice Prasad, Kalpna Adams, Chad C. Quang, Eiping Taylor, Justin Stocker, Derek J. World J Nucl Med Original Article Cadmium Zinc Telluride (CZT) crystal-based myocardial perfusion imaging (MPI) cameras have increased count sensitivity compared to Anger cameras and can be used to lower either the injected activity or the image acquisition time. Institutions adopting CZT cameras need to decide whether to lower the injected activity or imaging time or attempt to lower both with a compromise. The aim of our study was to compare the scan time required to obtain similar count images using high activity protocol (HAP) versus low activity protocol (LAP) stratified by body mass index (BMI) and assess the impact on effective dose and our clinic workflow. Using a CZT camera, a cohort of 100 consecutive clinical patients imaged with LAP rest-stress MPI with approximately 185 MBq and 555 MBq activity was retrospectively compared to a similar cohort of 100 consecutive clinical patients imaged with HAP rest-stress MPI using approximately 370 MBq and 1110 MBq. Administered activity and BMI both had a statistically significant effect on scan time and radiation effective dose. LAP scans took an average of 9 min longer than HAP scans overall, P < 0.0001 and larger BMIs took longer than smaller BMIs, P < 0.0001. In addition, scan times were longer in men than women, P = 0.007. Effective dose was inversely proportional to BMI with an overall decrease of approximately 50% comparing LAP to HAP. For the same CZT camera, the LAP increased scan time while lowering the radiation effective dose when compared to HAP. The increase in scan time increased proportionally to BMI. The effective dose was inversely proportional to BMI. This increase in time did not have a significant impact on our local workflow, but its implications should be considered in the setting of LAP implementation, especially in obese or high patient volume practices. Medknow Publications & Media Pvt Ltd 2021-08-07 /pmc/articles/PMC8488894/ /pubmed/34703392 http://dx.doi.org/10.4103/wjnm.WJNM_123_20 Text en Copyright: © 2021 World Journal of Nuclear Medicine https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Prasad, Kalpna
Adams, Chad C.
Quang, Eiping
Taylor, Justin
Stocker, Derek J.
The effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice
title The effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice
title_full The effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice
title_fullStr The effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice
title_full_unstemmed The effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice
title_short The effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice
title_sort effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8488894/
https://www.ncbi.nlm.nih.gov/pubmed/34703392
http://dx.doi.org/10.4103/wjnm.WJNM_123_20
work_keys_str_mv AT prasadkalpna theeffectofbodymassindexonhighversuslowadministeredactivityprotocolmyocardialperfusionimagingscantimeandeffectivedoseusingacadmiumzinctelluridecamerainclinicalpractice
AT adamschadc theeffectofbodymassindexonhighversuslowadministeredactivityprotocolmyocardialperfusionimagingscantimeandeffectivedoseusingacadmiumzinctelluridecamerainclinicalpractice
AT quangeiping theeffectofbodymassindexonhighversuslowadministeredactivityprotocolmyocardialperfusionimagingscantimeandeffectivedoseusingacadmiumzinctelluridecamerainclinicalpractice
AT taylorjustin theeffectofbodymassindexonhighversuslowadministeredactivityprotocolmyocardialperfusionimagingscantimeandeffectivedoseusingacadmiumzinctelluridecamerainclinicalpractice
AT stockerderekj theeffectofbodymassindexonhighversuslowadministeredactivityprotocolmyocardialperfusionimagingscantimeandeffectivedoseusingacadmiumzinctelluridecamerainclinicalpractice
AT prasadkalpna effectofbodymassindexonhighversuslowadministeredactivityprotocolmyocardialperfusionimagingscantimeandeffectivedoseusingacadmiumzinctelluridecamerainclinicalpractice
AT adamschadc effectofbodymassindexonhighversuslowadministeredactivityprotocolmyocardialperfusionimagingscantimeandeffectivedoseusingacadmiumzinctelluridecamerainclinicalpractice
AT quangeiping effectofbodymassindexonhighversuslowadministeredactivityprotocolmyocardialperfusionimagingscantimeandeffectivedoseusingacadmiumzinctelluridecamerainclinicalpractice
AT taylorjustin effectofbodymassindexonhighversuslowadministeredactivityprotocolmyocardialperfusionimagingscantimeandeffectivedoseusingacadmiumzinctelluridecamerainclinicalpractice
AT stockerderekj effectofbodymassindexonhighversuslowadministeredactivityprotocolmyocardialperfusionimagingscantimeandeffectivedoseusingacadmiumzinctelluridecamerainclinicalpractice