Cargando…

A versatile technique for high-resolution three-dimensional imaging of human arterial segments using microcomputed tomography

BACKGROUND: Quantitative methods for evaluating microstructure of arterial specimens typically rely on histologic techniques that involve random sampling, which cannot account for the unique spatial distribution of features in three dimensions. METHODS: To overcome this limitation, we demonstrate a...

Descripción completa

Detalles Bibliográficos
Autores principales: Robinson, Scott T., Levey, Ruth E., Beatty, Rachel, Connolly, David, Dolan, Eimear B., Osborne, Nicholas H., Dockery, Peter, Henke, Peter K., Duffy, Garry P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8489243/
https://www.ncbi.nlm.nih.gov/pubmed/34617054
http://dx.doi.org/10.1016/j.jvssci.2020.08.001
_version_ 1784578314521804800
author Robinson, Scott T.
Levey, Ruth E.
Beatty, Rachel
Connolly, David
Dolan, Eimear B.
Osborne, Nicholas H.
Dockery, Peter
Henke, Peter K.
Duffy, Garry P.
author_facet Robinson, Scott T.
Levey, Ruth E.
Beatty, Rachel
Connolly, David
Dolan, Eimear B.
Osborne, Nicholas H.
Dockery, Peter
Henke, Peter K.
Duffy, Garry P.
author_sort Robinson, Scott T.
collection PubMed
description BACKGROUND: Quantitative methods for evaluating microstructure of arterial specimens typically rely on histologic techniques that involve random sampling, which cannot account for the unique spatial distribution of features in three dimensions. METHODS: To overcome this limitation, we demonstrate a nondestructive method for three-dimensional imaging of intact human blood vessels using microcomputed tomography (microCT). Human artery segments were dehydrated and stained in an iodine solution then imaged with a standard laboratory microCT scanner. Image visualization and segmentation was performed using commercially available and open source software. RESULTS: Staining of cadaveric vessels with iodine enabled clear visualization of the arterial wall with microCT, preserved tissue morphology, and generated high-resolution images with a voxel size of 5.4 μm. Various components of the arterial wall were segmented using a combination of manual and automatic thresholding algorithms. CONCLUSIONS: Our approach allows for spatial mapping of human artery tissue samples that can guide targeted histologic analysis of smaller tissue segments, provide geometric data to inform finite element models, quantify degree of atherosclerosis, and help to evaluate the foreign body response to intravascular medical implants. (JVS–Vascular Science 2020;2:13-19.) CLINICAL RELEVANCE: In this article, we describe a powerful technique for whole artery analysis of pathologic human tissue specimens that provides high-resolution spatial detail regarding composition of the blood vessel wall. The protocol described here is a valuable adjunct that can be used as a research tool to inform finite element modeling of arteries, quantify pathologic response (ie, neointimal hyperplasia and vascular calcification), and evaluate the tissue/device interface of implanted medical devices.
format Online
Article
Text
id pubmed-8489243
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-84892432021-10-05 A versatile technique for high-resolution three-dimensional imaging of human arterial segments using microcomputed tomography Robinson, Scott T. Levey, Ruth E. Beatty, Rachel Connolly, David Dolan, Eimear B. Osborne, Nicholas H. Dockery, Peter Henke, Peter K. Duffy, Garry P. JVS Vasc Sci Article BACKGROUND: Quantitative methods for evaluating microstructure of arterial specimens typically rely on histologic techniques that involve random sampling, which cannot account for the unique spatial distribution of features in three dimensions. METHODS: To overcome this limitation, we demonstrate a nondestructive method for three-dimensional imaging of intact human blood vessels using microcomputed tomography (microCT). Human artery segments were dehydrated and stained in an iodine solution then imaged with a standard laboratory microCT scanner. Image visualization and segmentation was performed using commercially available and open source software. RESULTS: Staining of cadaveric vessels with iodine enabled clear visualization of the arterial wall with microCT, preserved tissue morphology, and generated high-resolution images with a voxel size of 5.4 μm. Various components of the arterial wall were segmented using a combination of manual and automatic thresholding algorithms. CONCLUSIONS: Our approach allows for spatial mapping of human artery tissue samples that can guide targeted histologic analysis of smaller tissue segments, provide geometric data to inform finite element models, quantify degree of atherosclerosis, and help to evaluate the foreign body response to intravascular medical implants. (JVS–Vascular Science 2020;2:13-19.) CLINICAL RELEVANCE: In this article, we describe a powerful technique for whole artery analysis of pathologic human tissue specimens that provides high-resolution spatial detail regarding composition of the blood vessel wall. The protocol described here is a valuable adjunct that can be used as a research tool to inform finite element modeling of arteries, quantify pathologic response (ie, neointimal hyperplasia and vascular calcification), and evaluate the tissue/device interface of implanted medical devices. Elsevier 2020-09-01 /pmc/articles/PMC8489243/ /pubmed/34617054 http://dx.doi.org/10.1016/j.jvssci.2020.08.001 Text en © 2020 by the Society for Vascular Surgery. Published by Elsevier Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Robinson, Scott T.
Levey, Ruth E.
Beatty, Rachel
Connolly, David
Dolan, Eimear B.
Osborne, Nicholas H.
Dockery, Peter
Henke, Peter K.
Duffy, Garry P.
A versatile technique for high-resolution three-dimensional imaging of human arterial segments using microcomputed tomography
title A versatile technique for high-resolution three-dimensional imaging of human arterial segments using microcomputed tomography
title_full A versatile technique for high-resolution three-dimensional imaging of human arterial segments using microcomputed tomography
title_fullStr A versatile technique for high-resolution three-dimensional imaging of human arterial segments using microcomputed tomography
title_full_unstemmed A versatile technique for high-resolution three-dimensional imaging of human arterial segments using microcomputed tomography
title_short A versatile technique for high-resolution three-dimensional imaging of human arterial segments using microcomputed tomography
title_sort versatile technique for high-resolution three-dimensional imaging of human arterial segments using microcomputed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8489243/
https://www.ncbi.nlm.nih.gov/pubmed/34617054
http://dx.doi.org/10.1016/j.jvssci.2020.08.001
work_keys_str_mv AT robinsonscottt aversatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT leveyruthe aversatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT beattyrachel aversatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT connollydavid aversatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT dolaneimearb aversatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT osbornenicholash aversatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT dockerypeter aversatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT henkepeterk aversatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT duffygarryp aversatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT robinsonscottt versatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT leveyruthe versatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT beattyrachel versatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT connollydavid versatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT dolaneimearb versatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT osbornenicholash versatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT dockerypeter versatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT henkepeterk versatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography
AT duffygarryp versatiletechniqueforhighresolutionthreedimensionalimagingofhumanarterialsegmentsusingmicrocomputedtomography