Vitamin E highly cross-linked polyethylene reduces mid-term wear in primary total hip replacement: a meta-analysis and systematic review of randomized clinical trials using radiostereometric analysis

Vitamin E incorporation into highly cross-linked polyethylene (HXLPE) has been introduced to improve wear resistance, and vitamin E incorporated HXLPE (VEPE) has been used in total hip arthroplasty. The aim of this meta-analysis was to investigate the wear properties of VEPE in clinical practice by...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Zeng, Xiang, Shuai, Wu, Cuijiao, Wang, Yingzhen, Weng, Xisheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: British Editorial Society of Bone and Joint Surgery 2021
Materias:
Hip
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8489480/
https://www.ncbi.nlm.nih.gov/pubmed/34667647
http://dx.doi.org/10.1302/2058-5241.6.200072
_version_ 1784578346299949056
author Li, Zeng
Xiang, Shuai
Wu, Cuijiao
Wang, Yingzhen
Weng, Xisheng
author_facet Li, Zeng
Xiang, Shuai
Wu, Cuijiao
Wang, Yingzhen
Weng, Xisheng
author_sort Li, Zeng
collection PubMed
description Vitamin E incorporation into highly cross-linked polyethylene (HXLPE) has been introduced to improve wear resistance, and vitamin E incorporated HXLPE (VEPE) has been used in total hip arthroplasty. The aim of this meta-analysis was to investigate the wear properties of VEPE in clinical practice by synthesizing the data provided in randomized clinical trials. The effects on implant stability, functional outcomes and revision rate of VEPE were also compared with those of HXPLE or ultra-high molecular weight polyethylene (UHMWPE). Literature searches were conducted on 1 January 2020 using MEDLINE, EMBASE, Cochrane and ClinicalTrials.gov databases. Randomized controlled trials (RCTs) comparing the aforementioned parameters between VEPE and standard HXPLE/UHMWPE liners were included. Methodological quality and the bias of the included studies were analysed. Meta-analyses were performed using the Review Manager software. Nine RCTs met the eligibility criteria and were included. At early and mid-term follow-up, the vertical penetration and the total penetration of the femoral head were both significantly reduced in the VEPE group. The steady state wear rate of the VEPE group was also remarkably lower. However, at two-year follow-up, significantly increased cup migration was observed in the VEPE group. Moreover, the mid-term clinical outcomes of the VEPE group were worse, while the total revision rates between the two groups were not significantly different. The limited number of included studies may compromise our conclusion regarding clinical outcomes of the VEPE bearing surface. More RCTs with longer follow-up periods are needed to further investigate the effects of VEPE in total hip arthroplasty. Cite this article: EFORT Open Rev 2021;6:759-770. DOI: 10.1302/2058-5241.6.200072
format Online
Article
Text
id pubmed-8489480
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher British Editorial Society of Bone and Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-84894802021-10-18 Vitamin E highly cross-linked polyethylene reduces mid-term wear in primary total hip replacement: a meta-analysis and systematic review of randomized clinical trials using radiostereometric analysis Li, Zeng Xiang, Shuai Wu, Cuijiao Wang, Yingzhen Weng, Xisheng EFORT Open Rev Hip Vitamin E incorporation into highly cross-linked polyethylene (HXLPE) has been introduced to improve wear resistance, and vitamin E incorporated HXLPE (VEPE) has been used in total hip arthroplasty. The aim of this meta-analysis was to investigate the wear properties of VEPE in clinical practice by synthesizing the data provided in randomized clinical trials. The effects on implant stability, functional outcomes and revision rate of VEPE were also compared with those of HXPLE or ultra-high molecular weight polyethylene (UHMWPE). Literature searches were conducted on 1 January 2020 using MEDLINE, EMBASE, Cochrane and ClinicalTrials.gov databases. Randomized controlled trials (RCTs) comparing the aforementioned parameters between VEPE and standard HXPLE/UHMWPE liners were included. Methodological quality and the bias of the included studies were analysed. Meta-analyses were performed using the Review Manager software. Nine RCTs met the eligibility criteria and were included. At early and mid-term follow-up, the vertical penetration and the total penetration of the femoral head were both significantly reduced in the VEPE group. The steady state wear rate of the VEPE group was also remarkably lower. However, at two-year follow-up, significantly increased cup migration was observed in the VEPE group. Moreover, the mid-term clinical outcomes of the VEPE group were worse, while the total revision rates between the two groups were not significantly different. The limited number of included studies may compromise our conclusion regarding clinical outcomes of the VEPE bearing surface. More RCTs with longer follow-up periods are needed to further investigate the effects of VEPE in total hip arthroplasty. Cite this article: EFORT Open Rev 2021;6:759-770. DOI: 10.1302/2058-5241.6.200072 British Editorial Society of Bone and Joint Surgery 2021-09-14 /pmc/articles/PMC8489480/ /pubmed/34667647 http://dx.doi.org/10.1302/2058-5241.6.200072 Text en © 2021 The author(s) https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-Non Commercial 4.0 International (CC BY-NC 4.0) licence (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed.
spellingShingle Hip
Li, Zeng
Xiang, Shuai
Wu, Cuijiao
Wang, Yingzhen
Weng, Xisheng
Vitamin E highly cross-linked polyethylene reduces mid-term wear in primary total hip replacement: a meta-analysis and systematic review of randomized clinical trials using radiostereometric analysis
title Vitamin E highly cross-linked polyethylene reduces mid-term wear in primary total hip replacement: a meta-analysis and systematic review of randomized clinical trials using radiostereometric analysis
title_full Vitamin E highly cross-linked polyethylene reduces mid-term wear in primary total hip replacement: a meta-analysis and systematic review of randomized clinical trials using radiostereometric analysis
title_fullStr Vitamin E highly cross-linked polyethylene reduces mid-term wear in primary total hip replacement: a meta-analysis and systematic review of randomized clinical trials using radiostereometric analysis
title_full_unstemmed Vitamin E highly cross-linked polyethylene reduces mid-term wear in primary total hip replacement: a meta-analysis and systematic review of randomized clinical trials using radiostereometric analysis
title_short Vitamin E highly cross-linked polyethylene reduces mid-term wear in primary total hip replacement: a meta-analysis and systematic review of randomized clinical trials using radiostereometric analysis
title_sort vitamin e highly cross-linked polyethylene reduces mid-term wear in primary total hip replacement: a meta-analysis and systematic review of randomized clinical trials using radiostereometric analysis
topic Hip
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8489480/
https://www.ncbi.nlm.nih.gov/pubmed/34667647
http://dx.doi.org/10.1302/2058-5241.6.200072
work_keys_str_mv AT lizeng vitaminehighlycrosslinkedpolyethylenereducesmidtermwearinprimarytotalhipreplacementametaanalysisandsystematicreviewofrandomizedclinicaltrialsusingradiostereometricanalysis
AT xiangshuai vitaminehighlycrosslinkedpolyethylenereducesmidtermwearinprimarytotalhipreplacementametaanalysisandsystematicreviewofrandomizedclinicaltrialsusingradiostereometricanalysis
AT wucuijiao vitaminehighlycrosslinkedpolyethylenereducesmidtermwearinprimarytotalhipreplacementametaanalysisandsystematicreviewofrandomizedclinicaltrialsusingradiostereometricanalysis
AT wangyingzhen vitaminehighlycrosslinkedpolyethylenereducesmidtermwearinprimarytotalhipreplacementametaanalysisandsystematicreviewofrandomizedclinicaltrialsusingradiostereometricanalysis
AT wengxisheng vitaminehighlycrosslinkedpolyethylenereducesmidtermwearinprimarytotalhipreplacementametaanalysisandsystematicreviewofrandomizedclinicaltrialsusingradiostereometricanalysis