Cargando…
Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults
BACKGROUND: The ultrasonic stadiometer was originally developed as a device to measure and monitor children’s height. However, an ultrasonic stadiometer (InLab S50; InBody Co., Seoul, Korea) was used to measure adults’ height in the 2018 Korea Community Health Survey (KCHS). This study was conducted...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Family Medicine
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8490171/ https://www.ncbi.nlm.nih.gov/pubmed/34607413 http://dx.doi.org/10.4082/kjfm.20.0202 |
_version_ | 1784578473313959936 |
---|---|
author | Cho, Seon Hwa Cho, Young Gyu Park, Hyun Ah Bong, A Ra |
author_facet | Cho, Seon Hwa Cho, Young Gyu Park, Hyun Ah Bong, A Ra |
author_sort | Cho, Seon Hwa |
collection | PubMed |
description | BACKGROUND: The ultrasonic stadiometer was originally developed as a device to measure and monitor children’s height. However, an ultrasonic stadiometer (InLab S50; InBody Co., Seoul, Korea) was used to measure adults’ height in the 2018 Korea Community Health Survey (KCHS). This study was conducted to assess the reliability and validity of the InLab S50 in adults. METHODS: The study subjects were 120 adults (reliability test, n=20; validity test, n=100) who had visited a health screening center. The intra- and inter-rater reliabilities of InLab S50 were assessed using the intraclass correlation coefficient (ICC). The agreement between InLab S50 and an automatic stadiometer (HM-201; Fanics, Busan, Korea) was assessed using Pearson’s correlation coefficient and Bland-Altman analysis. RESULTS: The intra- and inter-rater reliabilities of the InLab S50 were excellent (ICC=0.9999 and 0.9998, respectively). The correlation coefficient of the height measured by the two measurement devices was very high (r=0.996). The difference (Δheight [HM-201-InLab S50]) was -0.15±0.78 cm (95% limit of agreement [LOA], -1.69 to 1.38). After excluding the values outside 95% LOA, the difference was further reduced to -0.05±0.59 cm (95% LOA, -1.20 to 1.10). CONCLUSION: This study showed that the InLab S50 is a reliable and valid device for the measurement of adults’ height. Therefore, we think that InLab S50 could be used to measure adults’ height in household health surveys such as the KCHS. |
format | Online Article Text |
id | pubmed-8490171 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Korean Academy of Family Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-84901712021-10-08 Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults Cho, Seon Hwa Cho, Young Gyu Park, Hyun Ah Bong, A Ra Korean J Fam Med Original Article BACKGROUND: The ultrasonic stadiometer was originally developed as a device to measure and monitor children’s height. However, an ultrasonic stadiometer (InLab S50; InBody Co., Seoul, Korea) was used to measure adults’ height in the 2018 Korea Community Health Survey (KCHS). This study was conducted to assess the reliability and validity of the InLab S50 in adults. METHODS: The study subjects were 120 adults (reliability test, n=20; validity test, n=100) who had visited a health screening center. The intra- and inter-rater reliabilities of InLab S50 were assessed using the intraclass correlation coefficient (ICC). The agreement between InLab S50 and an automatic stadiometer (HM-201; Fanics, Busan, Korea) was assessed using Pearson’s correlation coefficient and Bland-Altman analysis. RESULTS: The intra- and inter-rater reliabilities of the InLab S50 were excellent (ICC=0.9999 and 0.9998, respectively). The correlation coefficient of the height measured by the two measurement devices was very high (r=0.996). The difference (Δheight [HM-201-InLab S50]) was -0.15±0.78 cm (95% limit of agreement [LOA], -1.69 to 1.38). After excluding the values outside 95% LOA, the difference was further reduced to -0.05±0.59 cm (95% LOA, -1.20 to 1.10). CONCLUSION: This study showed that the InLab S50 is a reliable and valid device for the measurement of adults’ height. Therefore, we think that InLab S50 could be used to measure adults’ height in household health surveys such as the KCHS. Korean Academy of Family Medicine 2021-09 2021-09-20 /pmc/articles/PMC8490171/ /pubmed/34607413 http://dx.doi.org/10.4082/kjfm.20.0202 Text en Copyright © 2021 The Korean Academy of Family Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Cho, Seon Hwa Cho, Young Gyu Park, Hyun Ah Bong, A Ra Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults |
title | Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults |
title_full | Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults |
title_fullStr | Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults |
title_full_unstemmed | Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults |
title_short | Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults |
title_sort | reliability and validity of an ultrasonic device for measuring height in adults |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8490171/ https://www.ncbi.nlm.nih.gov/pubmed/34607413 http://dx.doi.org/10.4082/kjfm.20.0202 |
work_keys_str_mv | AT choseonhwa reliabilityandvalidityofanultrasonicdeviceformeasuringheightinadults AT choyounggyu reliabilityandvalidityofanultrasonicdeviceformeasuringheightinadults AT parkhyunah reliabilityandvalidityofanultrasonicdeviceformeasuringheightinadults AT bongara reliabilityandvalidityofanultrasonicdeviceformeasuringheightinadults |