Cargando…

Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults

BACKGROUND: The ultrasonic stadiometer was originally developed as a device to measure and monitor children’s height. However, an ultrasonic stadiometer (InLab S50; InBody Co., Seoul, Korea) was used to measure adults’ height in the 2018 Korea Community Health Survey (KCHS). This study was conducted...

Descripción completa

Detalles Bibliográficos
Autores principales: Cho, Seon Hwa, Cho, Young Gyu, Park, Hyun Ah, Bong, A Ra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Family Medicine 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8490171/
https://www.ncbi.nlm.nih.gov/pubmed/34607413
http://dx.doi.org/10.4082/kjfm.20.0202
_version_ 1784578473313959936
author Cho, Seon Hwa
Cho, Young Gyu
Park, Hyun Ah
Bong, A Ra
author_facet Cho, Seon Hwa
Cho, Young Gyu
Park, Hyun Ah
Bong, A Ra
author_sort Cho, Seon Hwa
collection PubMed
description BACKGROUND: The ultrasonic stadiometer was originally developed as a device to measure and monitor children’s height. However, an ultrasonic stadiometer (InLab S50; InBody Co., Seoul, Korea) was used to measure adults’ height in the 2018 Korea Community Health Survey (KCHS). This study was conducted to assess the reliability and validity of the InLab S50 in adults. METHODS: The study subjects were 120 adults (reliability test, n=20; validity test, n=100) who had visited a health screening center. The intra- and inter-rater reliabilities of InLab S50 were assessed using the intraclass correlation coefficient (ICC). The agreement between InLab S50 and an automatic stadiometer (HM-201; Fanics, Busan, Korea) was assessed using Pearson’s correlation coefficient and Bland-Altman analysis. RESULTS: The intra- and inter-rater reliabilities of the InLab S50 were excellent (ICC=0.9999 and 0.9998, respectively). The correlation coefficient of the height measured by the two measurement devices was very high (r=0.996). The difference (Δheight [HM-201-InLab S50]) was -0.15±0.78 cm (95% limit of agreement [LOA], -1.69 to 1.38). After excluding the values outside 95% LOA, the difference was further reduced to -0.05±0.59 cm (95% LOA, -1.20 to 1.10). CONCLUSION: This study showed that the InLab S50 is a reliable and valid device for the measurement of adults’ height. Therefore, we think that InLab S50 could be used to measure adults’ height in household health surveys such as the KCHS.
format Online
Article
Text
id pubmed-8490171
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Academy of Family Medicine
record_format MEDLINE/PubMed
spelling pubmed-84901712021-10-08 Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults Cho, Seon Hwa Cho, Young Gyu Park, Hyun Ah Bong, A Ra Korean J Fam Med Original Article BACKGROUND: The ultrasonic stadiometer was originally developed as a device to measure and monitor children’s height. However, an ultrasonic stadiometer (InLab S50; InBody Co., Seoul, Korea) was used to measure adults’ height in the 2018 Korea Community Health Survey (KCHS). This study was conducted to assess the reliability and validity of the InLab S50 in adults. METHODS: The study subjects were 120 adults (reliability test, n=20; validity test, n=100) who had visited a health screening center. The intra- and inter-rater reliabilities of InLab S50 were assessed using the intraclass correlation coefficient (ICC). The agreement between InLab S50 and an automatic stadiometer (HM-201; Fanics, Busan, Korea) was assessed using Pearson’s correlation coefficient and Bland-Altman analysis. RESULTS: The intra- and inter-rater reliabilities of the InLab S50 were excellent (ICC=0.9999 and 0.9998, respectively). The correlation coefficient of the height measured by the two measurement devices was very high (r=0.996). The difference (Δheight [HM-201-InLab S50]) was -0.15±0.78 cm (95% limit of agreement [LOA], -1.69 to 1.38). After excluding the values outside 95% LOA, the difference was further reduced to -0.05±0.59 cm (95% LOA, -1.20 to 1.10). CONCLUSION: This study showed that the InLab S50 is a reliable and valid device for the measurement of adults’ height. Therefore, we think that InLab S50 could be used to measure adults’ height in household health surveys such as the KCHS. Korean Academy of Family Medicine 2021-09 2021-09-20 /pmc/articles/PMC8490171/ /pubmed/34607413 http://dx.doi.org/10.4082/kjfm.20.0202 Text en Copyright © 2021 The Korean Academy of Family Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Cho, Seon Hwa
Cho, Young Gyu
Park, Hyun Ah
Bong, A Ra
Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults
title Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults
title_full Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults
title_fullStr Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults
title_full_unstemmed Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults
title_short Reliability and Validity of an Ultrasonic Device for Measuring Height in Adults
title_sort reliability and validity of an ultrasonic device for measuring height in adults
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8490171/
https://www.ncbi.nlm.nih.gov/pubmed/34607413
http://dx.doi.org/10.4082/kjfm.20.0202
work_keys_str_mv AT choseonhwa reliabilityandvalidityofanultrasonicdeviceformeasuringheightinadults
AT choyounggyu reliabilityandvalidityofanultrasonicdeviceformeasuringheightinadults
AT parkhyunah reliabilityandvalidityofanultrasonicdeviceformeasuringheightinadults
AT bongara reliabilityandvalidityofanultrasonicdeviceformeasuringheightinadults