Cargando…

Magnetic resonance cisternography imaging findings related to the leakage of Gadolinium into the subarachnoid space

PURPOSE: To identify magnetic resonance cisternography (MRC) imaging findings related to Gadolinium-based contrast agent (GBCA) leakage into the subarachnoid space. MATERIALS AND METHODS: The number of voxels of GBCA leakage (V-leak) on 3D-real inversion recovery images was measured in 56 patients s...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakamichi, Rei, Taoka, Toshiaki, Kawai, Hisashi, Yoshida, Tadao, Sone, Michihiko, Naganawa, Shinji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Singapore 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8490263/
https://www.ncbi.nlm.nih.gov/pubmed/34050492
http://dx.doi.org/10.1007/s11604-021-01137-1
Descripción
Sumario:PURPOSE: To identify magnetic resonance cisternography (MRC) imaging findings related to Gadolinium-based contrast agent (GBCA) leakage into the subarachnoid space. MATERIALS AND METHODS: The number of voxels of GBCA leakage (V-leak) on 3D-real inversion recovery images was measured in 56 patients scanned 4 h post-intravenous GBCA injection. Bridging veins (BVs) were identified on MRC. The numbers of BVs with surrounding cystic structures (BV-cyst), with arachnoid granulations protruding into the superior sagittal sinus (BV-AG-SSS) and the skull (BV-AG-skull), and including any of these factors (BV-incl) were recorded. Correlations between these variables and V-leak were examined based on the Spearman’s rank correlation coefficient. Receiver-operating characteristic (ROC) curves were generated to investigate the predictive performance of GBCA leakage. RESULTS: V-leak and the number of BV-incl were strongly correlated (r = 0.609, p < 0.0001). The numbers of BV-cyst and BV-AG-skull had weaker correlations with V-leak (r = 0.364, p = 0.006; r = 0.311, p = 0.020, respectively). The number of BV-AG-SSS was not correlated with V-leak. The ROC curve for contrast leakage exceeding 1000 voxels and the number of BV-incl had moderate accuracy, with an area under the curve of 0.871. CONCLUSION: The number of BV-incl may be a predictor of GBCA leakage and a biomarker for waste drainage function without using GBCA.