Cargando…
Efficacy of Hemiarthroplasty vs. Locking Plate Fixation for Proximal Humerus Fractures: A Meta-Analysis
Background: Proximal humerus fractures are common in a clinic and account for ~6% of all adult fractures. Hemiarthroplasty (HA) or locking plate (LP) fixation is currently recommended for the treatment of complex proximal humerus fractures (PHFs); however, there is no uniform standard for optimal su...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8490867/ https://www.ncbi.nlm.nih.gov/pubmed/34621778 http://dx.doi.org/10.3389/fsurg.2021.651554 |
_version_ | 1784578615216701440 |
---|---|
author | Deng, Jiali Zhang, Shuai Yu, Yuanyuan Zhang, Li Zhang, Li Jiang, Wen Yang, Kai Xi, Xiaoyan |
author_facet | Deng, Jiali Zhang, Shuai Yu, Yuanyuan Zhang, Li Zhang, Li Jiang, Wen Yang, Kai Xi, Xiaoyan |
author_sort | Deng, Jiali |
collection | PubMed |
description | Background: Proximal humerus fractures are common in a clinic and account for ~6% of all adult fractures. Hemiarthroplasty (HA) or locking plate (LP) fixation is currently recommended for the treatment of complex proximal humerus fractures (PHFs); however, there is no uniform standard for optimal surgical treatment or functional recovery. We conducted a meta-analysis to compare the efficacy of LP and HA in the treatment of PHFs. Methods: Relative studies associated with HA and LP were searched in December 2020 in the PubMed, Embase, Cochrane Library, and OVID databases. The quality of the studies, functional outcomes (including the Constant-Murley score (CMS), American Shoulder and Elbow Surgeons Score (ASES), Simple Shoulder Test (SST), Short Form Health Survey (SF-12v2), complications, and reoperation rate were extracted and analyzed with the Stata 14.0 software. Results: A total of 958 patients from 12 studies were included in the meta-analysis, which showed that patients treated with LP had a significantly lower reoperation rate, a higher complication rate, and a higher CMS score than those treated with HA. There were no significant differences in ASES, SST, or SF-12v2 scores between treatment groups. Conclusions: Compared with HA, LP exhibited better clinical efficacy in some aspects. However, large sample and randomized, controlled studies are needed for further validation. |
format | Online Article Text |
id | pubmed-8490867 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-84908672021-10-06 Efficacy of Hemiarthroplasty vs. Locking Plate Fixation for Proximal Humerus Fractures: A Meta-Analysis Deng, Jiali Zhang, Shuai Yu, Yuanyuan Zhang, Li Zhang, Li Jiang, Wen Yang, Kai Xi, Xiaoyan Front Surg Surgery Background: Proximal humerus fractures are common in a clinic and account for ~6% of all adult fractures. Hemiarthroplasty (HA) or locking plate (LP) fixation is currently recommended for the treatment of complex proximal humerus fractures (PHFs); however, there is no uniform standard for optimal surgical treatment or functional recovery. We conducted a meta-analysis to compare the efficacy of LP and HA in the treatment of PHFs. Methods: Relative studies associated with HA and LP were searched in December 2020 in the PubMed, Embase, Cochrane Library, and OVID databases. The quality of the studies, functional outcomes (including the Constant-Murley score (CMS), American Shoulder and Elbow Surgeons Score (ASES), Simple Shoulder Test (SST), Short Form Health Survey (SF-12v2), complications, and reoperation rate were extracted and analyzed with the Stata 14.0 software. Results: A total of 958 patients from 12 studies were included in the meta-analysis, which showed that patients treated with LP had a significantly lower reoperation rate, a higher complication rate, and a higher CMS score than those treated with HA. There were no significant differences in ASES, SST, or SF-12v2 scores between treatment groups. Conclusions: Compared with HA, LP exhibited better clinical efficacy in some aspects. However, large sample and randomized, controlled studies are needed for further validation. Frontiers Media S.A. 2021-09-21 /pmc/articles/PMC8490867/ /pubmed/34621778 http://dx.doi.org/10.3389/fsurg.2021.651554 Text en Copyright © 2021 Deng, Zhang, Yu, Zhang, Zhang, Jiang, Yang and Xi. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Deng, Jiali Zhang, Shuai Yu, Yuanyuan Zhang, Li Zhang, Li Jiang, Wen Yang, Kai Xi, Xiaoyan Efficacy of Hemiarthroplasty vs. Locking Plate Fixation for Proximal Humerus Fractures: A Meta-Analysis |
title | Efficacy of Hemiarthroplasty vs. Locking Plate Fixation for Proximal Humerus Fractures: A Meta-Analysis |
title_full | Efficacy of Hemiarthroplasty vs. Locking Plate Fixation for Proximal Humerus Fractures: A Meta-Analysis |
title_fullStr | Efficacy of Hemiarthroplasty vs. Locking Plate Fixation for Proximal Humerus Fractures: A Meta-Analysis |
title_full_unstemmed | Efficacy of Hemiarthroplasty vs. Locking Plate Fixation for Proximal Humerus Fractures: A Meta-Analysis |
title_short | Efficacy of Hemiarthroplasty vs. Locking Plate Fixation for Proximal Humerus Fractures: A Meta-Analysis |
title_sort | efficacy of hemiarthroplasty vs. locking plate fixation for proximal humerus fractures: a meta-analysis |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8490867/ https://www.ncbi.nlm.nih.gov/pubmed/34621778 http://dx.doi.org/10.3389/fsurg.2021.651554 |
work_keys_str_mv | AT dengjiali efficacyofhemiarthroplastyvslockingplatefixationforproximalhumerusfracturesametaanalysis AT zhangshuai efficacyofhemiarthroplastyvslockingplatefixationforproximalhumerusfracturesametaanalysis AT yuyuanyuan efficacyofhemiarthroplastyvslockingplatefixationforproximalhumerusfracturesametaanalysis AT zhangli efficacyofhemiarthroplastyvslockingplatefixationforproximalhumerusfracturesametaanalysis AT zhangli efficacyofhemiarthroplastyvslockingplatefixationforproximalhumerusfracturesametaanalysis AT jiangwen efficacyofhemiarthroplastyvslockingplatefixationforproximalhumerusfracturesametaanalysis AT yangkai efficacyofhemiarthroplastyvslockingplatefixationforproximalhumerusfracturesametaanalysis AT xixiaoyan efficacyofhemiarthroplastyvslockingplatefixationforproximalhumerusfracturesametaanalysis |