Cargando…
Importance of Beam-Matching between TrueBeam STx and Novalis Tx in Pre-Treatment Quality Assurance Using Portal Dosimetry
Flexibility and efficiency in a radiotherapy department with different linear accelerators (linacs) can be improved if they are dosimetrically equivalent, and there is no need of plan or patient-specific quality assurance (PSQA) modification. From 2012 to 2017, our institution purchased three Novali...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8491317/ https://www.ncbi.nlm.nih.gov/pubmed/34703106 http://dx.doi.org/10.4103/jmp.JMP_12_21 |
_version_ | 1784578715748925440 |
---|---|
author | Rojas-López, José Alejandro Venencia, Daniel |
author_facet | Rojas-López, José Alejandro Venencia, Daniel |
author_sort | Rojas-López, José Alejandro |
collection | PubMed |
description | Flexibility and efficiency in a radiotherapy department with different linear accelerators (linacs) can be improved if they are dosimetrically equivalent, and there is no need of plan or patient-specific quality assurance (PSQA) modification. From 2012 to 2017, our institution purchased three Novalis Tx and one TrueBeam STx beam-matched accelerators with the same high-resolution multileaf collimator (MLC). They are matched taking as reference dosimetric data from Novalis Tx SN-5479. We showed the importance of beam-matched dosimetric units by the use of electronic portal image device (EPID) and Delta4 PSQA. It was able to treat patients on a different machine than the machine used for PSQA. Depth dose, beam profiles, output factors, dosimetric leaf gap, and MLC transmission were compared for all energies and linacs. PSQA in all linacs for 30 volumetric-modulated arc therapy plans was also compared. Prostate, breast, and head-and-neck cases were selected to consider low, middle, and high plan complexity, respectively. The comparisons were evaluated using EPID and Delta4 phantom. Dosimetric differences between the three Novalis Tx and TrueBeam STx in all energies were lower than 1%. The only significant difference was observed in Novalis EPID in middle complexity when the criterion was tighter in distance. This result could be related with the nonsymmetric dose delivery of semi arcs. In all other cases, there were no differences in two different EPID evaluations. However, TrueBeam EPID values were slightly higher than Novalis EPID values. This could be associated with the high-resolution novel diode detector TrueBeam EPID. The dosimetric data indicated that the Novalis Tx and TrueBeam STx are equivalent. PSQA using EPID and Delta4 phantom showed that there are no dosimetric differences in any of the linacs. These results revealed the flexibility performance in PSQA by beam-matching. |
format | Online Article Text |
id | pubmed-8491317 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-84913172021-10-25 Importance of Beam-Matching between TrueBeam STx and Novalis Tx in Pre-Treatment Quality Assurance Using Portal Dosimetry Rojas-López, José Alejandro Venencia, Daniel J Med Phys Technical Note Flexibility and efficiency in a radiotherapy department with different linear accelerators (linacs) can be improved if they are dosimetrically equivalent, and there is no need of plan or patient-specific quality assurance (PSQA) modification. From 2012 to 2017, our institution purchased three Novalis Tx and one TrueBeam STx beam-matched accelerators with the same high-resolution multileaf collimator (MLC). They are matched taking as reference dosimetric data from Novalis Tx SN-5479. We showed the importance of beam-matched dosimetric units by the use of electronic portal image device (EPID) and Delta4 PSQA. It was able to treat patients on a different machine than the machine used for PSQA. Depth dose, beam profiles, output factors, dosimetric leaf gap, and MLC transmission were compared for all energies and linacs. PSQA in all linacs for 30 volumetric-modulated arc therapy plans was also compared. Prostate, breast, and head-and-neck cases were selected to consider low, middle, and high plan complexity, respectively. The comparisons were evaluated using EPID and Delta4 phantom. Dosimetric differences between the three Novalis Tx and TrueBeam STx in all energies were lower than 1%. The only significant difference was observed in Novalis EPID in middle complexity when the criterion was tighter in distance. This result could be related with the nonsymmetric dose delivery of semi arcs. In all other cases, there were no differences in two different EPID evaluations. However, TrueBeam EPID values were slightly higher than Novalis EPID values. This could be associated with the high-resolution novel diode detector TrueBeam EPID. The dosimetric data indicated that the Novalis Tx and TrueBeam STx are equivalent. PSQA using EPID and Delta4 phantom showed that there are no dosimetric differences in any of the linacs. These results revealed the flexibility performance in PSQA by beam-matching. Medknow Publications & Media Pvt Ltd 2021 2021-09-08 /pmc/articles/PMC8491317/ /pubmed/34703106 http://dx.doi.org/10.4103/jmp.JMP_12_21 Text en Copyright: © 2021 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Technical Note Rojas-López, José Alejandro Venencia, Daniel Importance of Beam-Matching between TrueBeam STx and Novalis Tx in Pre-Treatment Quality Assurance Using Portal Dosimetry |
title | Importance of Beam-Matching between TrueBeam STx and Novalis Tx in Pre-Treatment Quality Assurance Using Portal Dosimetry |
title_full | Importance of Beam-Matching between TrueBeam STx and Novalis Tx in Pre-Treatment Quality Assurance Using Portal Dosimetry |
title_fullStr | Importance of Beam-Matching between TrueBeam STx and Novalis Tx in Pre-Treatment Quality Assurance Using Portal Dosimetry |
title_full_unstemmed | Importance of Beam-Matching between TrueBeam STx and Novalis Tx in Pre-Treatment Quality Assurance Using Portal Dosimetry |
title_short | Importance of Beam-Matching between TrueBeam STx and Novalis Tx in Pre-Treatment Quality Assurance Using Portal Dosimetry |
title_sort | importance of beam-matching between truebeam stx and novalis tx in pre-treatment quality assurance using portal dosimetry |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8491317/ https://www.ncbi.nlm.nih.gov/pubmed/34703106 http://dx.doi.org/10.4103/jmp.JMP_12_21 |
work_keys_str_mv | AT rojaslopezjosealejandro importanceofbeammatchingbetweentruebeamstxandnovalistxinpretreatmentqualityassuranceusingportaldosimetry AT venenciadaniel importanceofbeammatchingbetweentruebeamstxandnovalistxinpretreatmentqualityassuranceusingportaldosimetry |