BACKGROUND: Colorectal cancer (CRC) is one of the leading causes of cancer-related death. Early detection is critical to reduce CRC morbidity and mortality. In order to meet this need, we developed a molecular clamping assay called the ColoScape (TM) assay for early colorectal cancer diagnostics. ME...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Qing, Pastor, Larry, Du, Jinwei, Powell, Michael J., Zhang, Aiguo, Bodmer, Walter, Wu, Jianzhong, Zheng, Shu, Sha, Michael Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8491914/
https://www.ncbi.nlm.nih.gov/pubmed/34610014
http://dx.doi.org/10.1371/journal.pone.0244332
Descripción
Sumario:BACKGROUND: Colorectal cancer (CRC) is one of the leading causes of cancer-related death. Early detection is critical to reduce CRC morbidity and mortality. In order to meet this need, we developed a molecular clamping assay called the ColoScape (TM) assay for early colorectal cancer diagnostics. METHODS: Nineteen mutations in four genes (APC, KRAS, BRAF and CTNNB1) associated with early events in CRC pathogenesis are targeted in the ColoScape(TM) assay. Xenonucleic Acid (XNA)-mediated qPCR clamping technology was applied to minimize the wild-type background amplification in order to improve assay sensitivity of CRC mutation detection. The assay analytical performance was verified and validated, cfDNA and FFPE CRC patient samples were evaluated, and an ROC curve was applied to evaluate its performance. RESULTS: The data showed that the assay analytical sensitivity was 0.5% Variant Allele Frequency, corresponding to ~7–8 copies of mutant DNA with 5 ng total DNA input per test. This assay is highly reproducible with intra-assay CV of <3% and inter-assay CV of <5%. We have investigated 380 clinical samples including plasma cfDNA and FFPE samples from patients with precancerous and different stages of CRC. The preliminary assay clinical specificity and sensitivity for CRC cfDNA were: 100% (95% CI, 80.3–97.5%) and 92.2% (95% CI, 94.7–100%), respectively, with AUC of 0.96; 96% specificity (95% CI, 77.6–99.7%) and 92% sensitivity (95% CI, 86.1–95.6%) with AUC of 0.94 for CRC FFPE; 95% specificity (95% CI, 82.5%–99.1%) and 62.5% sensitivity (95% CI, 35.8%–83.7%) with AUC of 0.79 for precancerous lesions cfDNA. CONCLUSIONS: The XNA-mediated molecular clamping assay is a rapid, precise, and sensitive assay for the detection of precancerous lesions cfDNA and CRC cfDNA or FFPE samples.