A discrepancy between CT angiography and transesophageal echocardiographic measurements of the annular size affect long-term survival following trans-catheter aortic valve replacement
Introduction: Accurate measurement of the aortic valve annulus is critical for proper valve sizing for the transcatheter aortic valve replacement (TAVR) procedure. While computed tomography angiography (CTA) is the widely-accepted standard, two-dimensional (2D) and three-dimensional(3D) transesophag...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tabriz University of Medical Sciences
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8493236/ https://www.ncbi.nlm.nih.gov/pubmed/34630968 http://dx.doi.org/10.34172/jcvtr.2021.39 |
_version_ | 1784579081085386752 |
---|---|
author | Singh, Siddarth Rutkowski, Piotr S. Dyachkov, Alexey Iyer, Vijay S. Pourafkari, Leili Nader, Nader D. |
author_facet | Singh, Siddarth Rutkowski, Piotr S. Dyachkov, Alexey Iyer, Vijay S. Pourafkari, Leili Nader, Nader D. |
author_sort | Singh, Siddarth |
collection | PubMed |
description | Introduction: Accurate measurement of the aortic valve annulus is critical for proper valve sizing for the transcatheter aortic valve replacement (TAVR) procedure. While computed tomography angiography (CTA) is the widely-accepted standard, two-dimensional (2D) and three-dimensional(3D) transesophageal echocardiography (TEE) is commonly performed to measure the size of the aortic valve and to verify appropriate seating of prostheses. Methods: Patients undergoing TAVR between 2013-2015 were examined. 2D- and 3D-TEEmeasurements were compared to CTA taken as standard. Patients were followed for at least one year. The presence and effect of discrepancy (defined as a difference of more than 10%) between CTA and TEE measurements on survival were examined. Results: One hundred eighty-five patients (70 men) were included. 2D- and 3D-TEE measurements underestimated the annulus size by -1.49 and -1.32 mm, respectively. Discrepancies > 10% between TEE and CTA methods in estimating the aortic annulus size were associated with a decrease in post implant survival. The peak pressure gradient across the aortic prosthesis measured one year after the implant was higher in patients with an initial discrepancy between 3D-TEE and CTA measurements. In a multivariate cox-regression model, the discrepancy between CTA and 2D-TEE readings and the smaller size of the aortic annular area were the predictors of long-term survival. Conclusion: Both 2D and 3D-TEE underestimate the aortic annulus measurements compared to CTA, with 2D-TEE being relatively more precise than 3D-TEE technology. The presence of a discrepancy between echocardiographic and CTA measurements of the aortic annulus is associated with a lower survival rate. |
format | Online Article Text |
id | pubmed-8493236 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Tabriz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-84932362021-10-08 A discrepancy between CT angiography and transesophageal echocardiographic measurements of the annular size affect long-term survival following trans-catheter aortic valve replacement Singh, Siddarth Rutkowski, Piotr S. Dyachkov, Alexey Iyer, Vijay S. Pourafkari, Leili Nader, Nader D. J Cardiovasc Thorac Res Original Article Introduction: Accurate measurement of the aortic valve annulus is critical for proper valve sizing for the transcatheter aortic valve replacement (TAVR) procedure. While computed tomography angiography (CTA) is the widely-accepted standard, two-dimensional (2D) and three-dimensional(3D) transesophageal echocardiography (TEE) is commonly performed to measure the size of the aortic valve and to verify appropriate seating of prostheses. Methods: Patients undergoing TAVR between 2013-2015 were examined. 2D- and 3D-TEEmeasurements were compared to CTA taken as standard. Patients were followed for at least one year. The presence and effect of discrepancy (defined as a difference of more than 10%) between CTA and TEE measurements on survival were examined. Results: One hundred eighty-five patients (70 men) were included. 2D- and 3D-TEE measurements underestimated the annulus size by -1.49 and -1.32 mm, respectively. Discrepancies > 10% between TEE and CTA methods in estimating the aortic annulus size were associated with a decrease in post implant survival. The peak pressure gradient across the aortic prosthesis measured one year after the implant was higher in patients with an initial discrepancy between 3D-TEE and CTA measurements. In a multivariate cox-regression model, the discrepancy between CTA and 2D-TEE readings and the smaller size of the aortic annular area were the predictors of long-term survival. Conclusion: Both 2D and 3D-TEE underestimate the aortic annulus measurements compared to CTA, with 2D-TEE being relatively more precise than 3D-TEE technology. The presence of a discrepancy between echocardiographic and CTA measurements of the aortic annulus is associated with a lower survival rate. Tabriz University of Medical Sciences 2021 2021-08-25 /pmc/articles/PMC8493236/ /pubmed/34630968 http://dx.doi.org/10.34172/jcvtr.2021.39 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Singh, Siddarth Rutkowski, Piotr S. Dyachkov, Alexey Iyer, Vijay S. Pourafkari, Leili Nader, Nader D. A discrepancy between CT angiography and transesophageal echocardiographic measurements of the annular size affect long-term survival following trans-catheter aortic valve replacement |
title | A discrepancy between CT angiography and transesophageal echocardiographic measurements of the annular size affect long-term survival following trans-catheter aortic valve replacement |
title_full | A discrepancy between CT angiography and transesophageal echocardiographic measurements of the annular size affect long-term survival following trans-catheter aortic valve replacement |
title_fullStr | A discrepancy between CT angiography and transesophageal echocardiographic measurements of the annular size affect long-term survival following trans-catheter aortic valve replacement |
title_full_unstemmed | A discrepancy between CT angiography and transesophageal echocardiographic measurements of the annular size affect long-term survival following trans-catheter aortic valve replacement |
title_short | A discrepancy between CT angiography and transesophageal echocardiographic measurements of the annular size affect long-term survival following trans-catheter aortic valve replacement |
title_sort | discrepancy between ct angiography and transesophageal echocardiographic measurements of the annular size affect long-term survival following trans-catheter aortic valve replacement |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8493236/ https://www.ncbi.nlm.nih.gov/pubmed/34630968 http://dx.doi.org/10.34172/jcvtr.2021.39 |
work_keys_str_mv | AT singhsiddarth adiscrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT rutkowskipiotrs adiscrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT dyachkovalexey adiscrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT iyervijays adiscrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT pourafkarileili adiscrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT nadernaderd adiscrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT singhsiddarth discrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT rutkowskipiotrs discrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT dyachkovalexey discrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT iyervijays discrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT pourafkarileili discrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement AT nadernaderd discrepancybetweenctangiographyandtransesophagealechocardiographicmeasurementsoftheannularsizeaffectlongtermsurvivalfollowingtranscatheteraorticvalvereplacement |