Cargando…
Grey-box modeling and hypothesis testing of functional near-infrared spectroscopy-based cerebrovascular reactivity to anodal high-definition tDCS in healthy humans
Transcranial direct current stimulation (tDCS) has been shown to evoke hemodynamics response; however, the mechanisms have not been investigated systematically using systems biology approaches. Our study presents a grey-box linear model that was developed from a physiologically detailed multi-compar...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8494321/ https://www.ncbi.nlm.nih.gov/pubmed/34613970 http://dx.doi.org/10.1371/journal.pcbi.1009386 |
_version_ | 1784579286499328000 |
---|---|
author | Arora, Yashika Walia, Pushpinder Hayashibe, Mitsuhiro Muthalib, Makii Chowdhury, Shubhajit Roy Perrey, Stephane Dutta, Anirban |
author_facet | Arora, Yashika Walia, Pushpinder Hayashibe, Mitsuhiro Muthalib, Makii Chowdhury, Shubhajit Roy Perrey, Stephane Dutta, Anirban |
author_sort | Arora, Yashika |
collection | PubMed |
description | Transcranial direct current stimulation (tDCS) has been shown to evoke hemodynamics response; however, the mechanisms have not been investigated systematically using systems biology approaches. Our study presents a grey-box linear model that was developed from a physiologically detailed multi-compartmental neurovascular unit model consisting of the vascular smooth muscle, perivascular space, synaptic space, and astrocyte glial cell. Then, model linearization was performed on the physiologically detailed nonlinear model to find appropriate complexity (Akaike information criterion) to fit functional near-infrared spectroscopy (fNIRS) based measure of blood volume changes, called cerebrovascular reactivity (CVR), to high-definition (HD) tDCS. The grey-box linear model was applied on the fNIRS-based CVR during the first 150 seconds of anodal HD-tDCS in eleven healthy humans. The grey-box linear models for each of the four nested pathways starting from tDCS scalp current density that perturbed synaptic potassium released from active neurons for Pathway 1, astrocytic transmembrane current for Pathway 2, perivascular potassium concentration for Pathway 3, and voltage-gated ion channel current on the smooth muscle cell for Pathway 4 were fitted to the total hemoglobin concentration (tHb) changes from optodes in the vicinity of 4x1 HD-tDCS electrodes as well as on the contralateral sensorimotor cortex. We found that the tDCS perturbation Pathway 3 presented the least mean square error (MSE, median <2.5%) and the lowest Akaike information criterion (AIC, median -1.726) from the individual grey-box linear model fitting at the targeted-region. Then, minimal realization transfer function with reduced-order approximations of the grey-box model pathways was fitted to the ensemble average tHb time series. Again, Pathway 3 with nine poles and two zeros (all free parameters), provided the best Goodness of Fit of 0.0078 for Chi-Square difference test of nested pathways. Therefore, our study provided a systems biology approach to investigate the initial transient hemodynamic response to tDCS based on fNIRS tHb data. Future studies need to investigate the steady-state responses, including steady-state oscillations found to be driven by calcium dynamics, where transcranial alternating current stimulation may provide frequency-dependent physiological entrainment for system identification. We postulate that such a mechanistic understanding from system identification of the hemodynamics response to transcranial electrical stimulation can facilitate adequate delivery of the current density to the neurovascular tissue under simultaneous portable imaging in various cerebrovascular diseases. |
format | Online Article Text |
id | pubmed-8494321 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-84943212021-10-07 Grey-box modeling and hypothesis testing of functional near-infrared spectroscopy-based cerebrovascular reactivity to anodal high-definition tDCS in healthy humans Arora, Yashika Walia, Pushpinder Hayashibe, Mitsuhiro Muthalib, Makii Chowdhury, Shubhajit Roy Perrey, Stephane Dutta, Anirban PLoS Comput Biol Research Article Transcranial direct current stimulation (tDCS) has been shown to evoke hemodynamics response; however, the mechanisms have not been investigated systematically using systems biology approaches. Our study presents a grey-box linear model that was developed from a physiologically detailed multi-compartmental neurovascular unit model consisting of the vascular smooth muscle, perivascular space, synaptic space, and astrocyte glial cell. Then, model linearization was performed on the physiologically detailed nonlinear model to find appropriate complexity (Akaike information criterion) to fit functional near-infrared spectroscopy (fNIRS) based measure of blood volume changes, called cerebrovascular reactivity (CVR), to high-definition (HD) tDCS. The grey-box linear model was applied on the fNIRS-based CVR during the first 150 seconds of anodal HD-tDCS in eleven healthy humans. The grey-box linear models for each of the four nested pathways starting from tDCS scalp current density that perturbed synaptic potassium released from active neurons for Pathway 1, astrocytic transmembrane current for Pathway 2, perivascular potassium concentration for Pathway 3, and voltage-gated ion channel current on the smooth muscle cell for Pathway 4 were fitted to the total hemoglobin concentration (tHb) changes from optodes in the vicinity of 4x1 HD-tDCS electrodes as well as on the contralateral sensorimotor cortex. We found that the tDCS perturbation Pathway 3 presented the least mean square error (MSE, median <2.5%) and the lowest Akaike information criterion (AIC, median -1.726) from the individual grey-box linear model fitting at the targeted-region. Then, minimal realization transfer function with reduced-order approximations of the grey-box model pathways was fitted to the ensemble average tHb time series. Again, Pathway 3 with nine poles and two zeros (all free parameters), provided the best Goodness of Fit of 0.0078 for Chi-Square difference test of nested pathways. Therefore, our study provided a systems biology approach to investigate the initial transient hemodynamic response to tDCS based on fNIRS tHb data. Future studies need to investigate the steady-state responses, including steady-state oscillations found to be driven by calcium dynamics, where transcranial alternating current stimulation may provide frequency-dependent physiological entrainment for system identification. We postulate that such a mechanistic understanding from system identification of the hemodynamics response to transcranial electrical stimulation can facilitate adequate delivery of the current density to the neurovascular tissue under simultaneous portable imaging in various cerebrovascular diseases. Public Library of Science 2021-10-06 /pmc/articles/PMC8494321/ /pubmed/34613970 http://dx.doi.org/10.1371/journal.pcbi.1009386 Text en © 2021 Arora et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Arora, Yashika Walia, Pushpinder Hayashibe, Mitsuhiro Muthalib, Makii Chowdhury, Shubhajit Roy Perrey, Stephane Dutta, Anirban Grey-box modeling and hypothesis testing of functional near-infrared spectroscopy-based cerebrovascular reactivity to anodal high-definition tDCS in healthy humans |
title | Grey-box modeling and hypothesis testing of functional near-infrared spectroscopy-based cerebrovascular reactivity to anodal high-definition tDCS in healthy humans |
title_full | Grey-box modeling and hypothesis testing of functional near-infrared spectroscopy-based cerebrovascular reactivity to anodal high-definition tDCS in healthy humans |
title_fullStr | Grey-box modeling and hypothesis testing of functional near-infrared spectroscopy-based cerebrovascular reactivity to anodal high-definition tDCS in healthy humans |
title_full_unstemmed | Grey-box modeling and hypothesis testing of functional near-infrared spectroscopy-based cerebrovascular reactivity to anodal high-definition tDCS in healthy humans |
title_short | Grey-box modeling and hypothesis testing of functional near-infrared spectroscopy-based cerebrovascular reactivity to anodal high-definition tDCS in healthy humans |
title_sort | grey-box modeling and hypothesis testing of functional near-infrared spectroscopy-based cerebrovascular reactivity to anodal high-definition tdcs in healthy humans |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8494321/ https://www.ncbi.nlm.nih.gov/pubmed/34613970 http://dx.doi.org/10.1371/journal.pcbi.1009386 |
work_keys_str_mv | AT arorayashika greyboxmodelingandhypothesistestingoffunctionalnearinfraredspectroscopybasedcerebrovascularreactivitytoanodalhighdefinitiontdcsinhealthyhumans AT waliapushpinder greyboxmodelingandhypothesistestingoffunctionalnearinfraredspectroscopybasedcerebrovascularreactivitytoanodalhighdefinitiontdcsinhealthyhumans AT hayashibemitsuhiro greyboxmodelingandhypothesistestingoffunctionalnearinfraredspectroscopybasedcerebrovascularreactivitytoanodalhighdefinitiontdcsinhealthyhumans AT muthalibmakii greyboxmodelingandhypothesistestingoffunctionalnearinfraredspectroscopybasedcerebrovascularreactivitytoanodalhighdefinitiontdcsinhealthyhumans AT chowdhuryshubhajitroy greyboxmodelingandhypothesistestingoffunctionalnearinfraredspectroscopybasedcerebrovascularreactivitytoanodalhighdefinitiontdcsinhealthyhumans AT perreystephane greyboxmodelingandhypothesistestingoffunctionalnearinfraredspectroscopybasedcerebrovascularreactivitytoanodalhighdefinitiontdcsinhealthyhumans AT duttaanirban greyboxmodelingandhypothesistestingoffunctionalnearinfraredspectroscopybasedcerebrovascularreactivitytoanodalhighdefinitiontdcsinhealthyhumans |