Cargando…
Transient electroretinographic abnormalities that mimic those of KCNV2 retinopathy: a case report
PURPOSE: The purpose of this report was to describe the case of a 68-year-old male patient with stage IV colon cancer who exhibited electroretinographic abnormalities that are similar to those of KCNV2 retinopathy. METHODS: The patient presenting with photophobia, reduced visual acuity, and poor gen...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8494656/ https://www.ncbi.nlm.nih.gov/pubmed/33738644 http://dx.doi.org/10.1007/s10633-021-09828-w |
Sumario: | PURPOSE: The purpose of this report was to describe the case of a 68-year-old male patient with stage IV colon cancer who exhibited electroretinographic abnormalities that are similar to those of KCNV2 retinopathy. METHODS: The patient presenting with photophobia, reduced visual acuity, and poor general conditions, the onset of which occurred ten days before presentation, was examined using fundoscopy, full-field electroretinography, blood tests, and abdominal computed tomography. RESULTS: The patient’s decimal best-corrected visual acuity (BCVA) was 0.4 in each eye. Fundoscopy showed bull's eye-like maculopathy in both eyes. Electroretinographic findings were similar to the characteristic findings of KCNV2 retinopathy: Rod electroretinogram showed delayed and preserved b-wave amplitudes; bright-flash electroretinogram showed double troughs of a-waves; b/a ratios shown by bright-flash electroretinogram were higher than those shown by standard-flash electroretinogram; and both cone and 30-Hz flicker electroretinograms showed extinguished responses. His serum potassium level increased to 6.2 mmol/L (normal range 3.6–4.8 mmol/L) owing to hydronephrosis resulting from disseminated carcinoma. After performing an emergency surgery to treat this condition, the serum potassium level immediately decreased to a normal range. Eleven days after presentation, rod and standard/bright-flash electroretinography showed improvement in the implicit time of the rod b-waves and the a-waves. Unexpectedly, the responses recorded by cone and 30-Hz flicker electroretinography became normal. The symptoms and maculopathy disappeared, and his BCVA improved to 1.2. CONCLUSIONS: The abnormal electroretinographic findings might be associated with the transient increase in serum potassium level. |
---|