Cargando…
Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium
BACKGROUND: There is a paucity of randomized data regarding the safety and efficacy of the use of intracardiac echocardiography (ICE) from the left atrium (LA) to guide left atrial appendage occlusion (LAAO) procedures under local anesthesia using either of the available devices. HYPOTHESIS: The aim...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wiley Periodicals, Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495078/ https://www.ncbi.nlm.nih.gov/pubmed/34498285 http://dx.doi.org/10.1002/clc.23696 |
_version_ | 1784579458121859072 |
---|---|
author | Pommier, Thibaut Guenancia, Charles Richard, Carole Sagnard, Audrey Fichot, Marie Salignon‐Vernay, Clemence Porot, Guillaume Laurent, Gabriel Lorgis, Luc |
author_facet | Pommier, Thibaut Guenancia, Charles Richard, Carole Sagnard, Audrey Fichot, Marie Salignon‐Vernay, Clemence Porot, Guillaume Laurent, Gabriel Lorgis, Luc |
author_sort | Pommier, Thibaut |
collection | PubMed |
description | BACKGROUND: There is a paucity of randomized data regarding the safety and efficacy of the use of intracardiac echocardiography (ICE) from the left atrium (LA) to guide left atrial appendage occlusion (LAAO) procedures under local anesthesia using either of the available devices. HYPOTHESIS: The aim of this study was to compare the efficacy and safety of ICE from the LA with transesophageal echocardiography (TEE) for guidance during transcatheter LAAO procedures. METHODS: Single‐center, cohort study of patients undergoing LAAO with the Amplatzer Cardiac Plug or Watchman device. Procedures were guided by ICE from the LA with local anesthesia (n = 175) or TEE under general anesthesia (n = 49). Efficacy outcomes were procedural success and peri‐device leaks 6 weeks after LAAO. The safety outcome was a composite of procedure‐related complications. RESULTS: Procedural success was similar between groups: 100% in the TEE‐guided group, and 98% in the ICE‐guided group. Procedure‐related complications such as death, embolism, migration, or major vascular complications occurred similarly between groups (p = 0.590). The rate and degree of peri‐device leaks or presence of a thrombus on the device did not differ between groups on follow‐up CT. Turnover time in the catheter laboratory and use of contrast agent were reduced with ICE. CONCLUSIONS: ICE in the left atrium to guide LAAO procedures appears to be as effective and safe as TEE. There was no increase in procedure‐related complications, whatever the device used. ICE resulted in similar procedural success while decreasing procedure time and requiring only local anesthesia. |
format | Online Article Text |
id | pubmed-8495078 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wiley Periodicals, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-84950782021-10-08 Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium Pommier, Thibaut Guenancia, Charles Richard, Carole Sagnard, Audrey Fichot, Marie Salignon‐Vernay, Clemence Porot, Guillaume Laurent, Gabriel Lorgis, Luc Clin Cardiol Clinical Investigations BACKGROUND: There is a paucity of randomized data regarding the safety and efficacy of the use of intracardiac echocardiography (ICE) from the left atrium (LA) to guide left atrial appendage occlusion (LAAO) procedures under local anesthesia using either of the available devices. HYPOTHESIS: The aim of this study was to compare the efficacy and safety of ICE from the LA with transesophageal echocardiography (TEE) for guidance during transcatheter LAAO procedures. METHODS: Single‐center, cohort study of patients undergoing LAAO with the Amplatzer Cardiac Plug or Watchman device. Procedures were guided by ICE from the LA with local anesthesia (n = 175) or TEE under general anesthesia (n = 49). Efficacy outcomes were procedural success and peri‐device leaks 6 weeks after LAAO. The safety outcome was a composite of procedure‐related complications. RESULTS: Procedural success was similar between groups: 100% in the TEE‐guided group, and 98% in the ICE‐guided group. Procedure‐related complications such as death, embolism, migration, or major vascular complications occurred similarly between groups (p = 0.590). The rate and degree of peri‐device leaks or presence of a thrombus on the device did not differ between groups on follow‐up CT. Turnover time in the catheter laboratory and use of contrast agent were reduced with ICE. CONCLUSIONS: ICE in the left atrium to guide LAAO procedures appears to be as effective and safe as TEE. There was no increase in procedure‐related complications, whatever the device used. ICE resulted in similar procedural success while decreasing procedure time and requiring only local anesthesia. Wiley Periodicals, Inc. 2021-09-08 /pmc/articles/PMC8495078/ /pubmed/34498285 http://dx.doi.org/10.1002/clc.23696 Text en © 2021 The Authors. Clinical Cardiology published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Investigations Pommier, Thibaut Guenancia, Charles Richard, Carole Sagnard, Audrey Fichot, Marie Salignon‐Vernay, Clemence Porot, Guillaume Laurent, Gabriel Lorgis, Luc Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium |
title | Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium |
title_full | Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium |
title_fullStr | Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium |
title_full_unstemmed | Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium |
title_short | Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium |
title_sort | safety and efficacy of left atrial appendage occlusion with the acp or watchman device guided by intracardiac echocardiography from the left atrium |
topic | Clinical Investigations |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495078/ https://www.ncbi.nlm.nih.gov/pubmed/34498285 http://dx.doi.org/10.1002/clc.23696 |
work_keys_str_mv | AT pommierthibaut safetyandefficacyofleftatrialappendageocclusionwiththeacporwatchmandeviceguidedbyintracardiacechocardiographyfromtheleftatrium AT guenanciacharles safetyandefficacyofleftatrialappendageocclusionwiththeacporwatchmandeviceguidedbyintracardiacechocardiographyfromtheleftatrium AT richardcarole safetyandefficacyofleftatrialappendageocclusionwiththeacporwatchmandeviceguidedbyintracardiacechocardiographyfromtheleftatrium AT sagnardaudrey safetyandefficacyofleftatrialappendageocclusionwiththeacporwatchmandeviceguidedbyintracardiacechocardiographyfromtheleftatrium AT fichotmarie safetyandefficacyofleftatrialappendageocclusionwiththeacporwatchmandeviceguidedbyintracardiacechocardiographyfromtheleftatrium AT salignonvernayclemence safetyandefficacyofleftatrialappendageocclusionwiththeacporwatchmandeviceguidedbyintracardiacechocardiographyfromtheleftatrium AT porotguillaume safetyandefficacyofleftatrialappendageocclusionwiththeacporwatchmandeviceguidedbyintracardiacechocardiographyfromtheleftatrium AT laurentgabriel safetyandefficacyofleftatrialappendageocclusionwiththeacporwatchmandeviceguidedbyintracardiacechocardiographyfromtheleftatrium AT lorgisluc safetyandefficacyofleftatrialappendageocclusionwiththeacporwatchmandeviceguidedbyintracardiacechocardiographyfromtheleftatrium |