Cargando…

Predictors and 3‐year outcomes of compromised left circumflex coronary artery after left main crossover stenting

BACKGROUND: There are few predictors of decreased fractional flow reserve (FFR) in the left circumflex coronary artery (LCx) after left main (LM) crossover stenting. OBJECTIVES: We aimed to determine the predictors for low FFR at LCx and possible treatment strategies for compromised LCx, together wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ullah, Hameed, Elakabawi, Karim, Ke, Han, Ullah, Najeeb, Ullah, Habib, Shah, Sardar Ali, Khan, Hamad Haider, Khan, Muhammad Asad, Guo, Ning, Yuan, Zuyi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wiley Periodicals, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495093/
https://www.ncbi.nlm.nih.gov/pubmed/34269478
http://dx.doi.org/10.1002/clc.23693
Descripción
Sumario:BACKGROUND: There are few predictors of decreased fractional flow reserve (FFR) in the left circumflex coronary artery (LCx) after left main (LM) crossover stenting. OBJECTIVES: We aimed to determine the predictors for low FFR at LCx and possible treatment strategies for compromised LCx, together with their long‐term outcomes. METHODS: Altogether, 563 patients who met the inclusion criteria were admitted to our hospital from February 2015 to November 2020 with significant distal LM bifurcation lesions. They underwent single‐stent crossover percutaneous coronary intervention (PCI) under intravascular ultrasound (IVUS) guidance with further LCx intervention based on the measured FFR. RESULTS: The patients showed significant angiographic LCx ostial affection post‐LM stenting, but only 116 (20.6%) patients had FFR < 0.8. The three‐year composite major adverse cardiac events (MACE) rates were comparable between the high and low FFR groups (16.8% vs. 15.5; p = 0.744). In a multivariate analysis, low FFR at the LCx was associated with post‐stenting minimal luminal area (MLA) of LCx (odds ratio [OR]: 0.032, p < .001), post‐stenting LCx plaque burden (OR: 1.166, p < .001), poststenting LM MLA (OR: 0.821, p = .038), and prestenting LCx MLA (OR: 0.371, p = .044). In the low FFR group, those with compromised LCx managed with drug‐eluting balloon had the lowest three‐year MACE rate (8.1%), as compared to either those undergoing kissing balloon inflation (KBI) (17.5%) or stenting (20.5%) (p = 0.299). CONCLUSION: Unnecessary LCx interventions can be avoided with FFR‐guided LCx intervention. Poststenting MLA and plaque burden of the LCx, and main vessel stent length are poststenting predictors of low FFR.