Cargando…

A novel technique for invasive aortic valve pressure gradient measurement using a 6 Fr Swan-Ganz catheter: a case series

BACKGROUND: Simultaneous left ventricular (LV) and aortic (Ao) pressure gradient assessment has been rendered challenging since the recall of the Langston catheter. Here we describe a simple method for simultaneous LV and Ao pressure gradient assessment using a Swan-Ganz catheter. CASE SUMMARY: We d...

Descripción completa

Detalles Bibliográficos
Autores principales: Agarwal, Nayan, Rastogi, Ujjwal, Mahmoud, Ahmed N, Bhatt, Deepak L
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495136/
https://www.ncbi.nlm.nih.gov/pubmed/34632266
http://dx.doi.org/10.1093/ehjcr/ytab383
_version_ 1784579472537681920
author Agarwal, Nayan
Rastogi, Ujjwal
Mahmoud, Ahmed N
Bhatt, Deepak L
author_facet Agarwal, Nayan
Rastogi, Ujjwal
Mahmoud, Ahmed N
Bhatt, Deepak L
author_sort Agarwal, Nayan
collection PubMed
description BACKGROUND: Simultaneous left ventricular (LV) and aortic (Ao) pressure gradient assessment has been rendered challenging since the recall of the Langston catheter. Here we describe a simple method for simultaneous LV and Ao pressure gradient assessment using a Swan-Ganz catheter. CASE SUMMARY: We describe two cases where assessment of simultaneous left ventricle and Ao valve gradients was done using a Swan-Ganz catheter to assess the degree of Ao stenosis and dynamic LV outflow obstruction. DISCUSSION: Using Swan-Ganz catheter assessment of simultaneous left ventricle and Ao valve gradients can simplify the procedure with reduced cost and increased patient safety.
format Online
Article
Text
id pubmed-8495136
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-84951362021-10-07 A novel technique for invasive aortic valve pressure gradient measurement using a 6 Fr Swan-Ganz catheter: a case series Agarwal, Nayan Rastogi, Ujjwal Mahmoud, Ahmed N Bhatt, Deepak L Eur Heart J Case Rep Case Report BACKGROUND: Simultaneous left ventricular (LV) and aortic (Ao) pressure gradient assessment has been rendered challenging since the recall of the Langston catheter. Here we describe a simple method for simultaneous LV and Ao pressure gradient assessment using a Swan-Ganz catheter. CASE SUMMARY: We describe two cases where assessment of simultaneous left ventricle and Ao valve gradients was done using a Swan-Ganz catheter to assess the degree of Ao stenosis and dynamic LV outflow obstruction. DISCUSSION: Using Swan-Ganz catheter assessment of simultaneous left ventricle and Ao valve gradients can simplify the procedure with reduced cost and increased patient safety. Oxford University Press 2021-09-24 /pmc/articles/PMC8495136/ /pubmed/34632266 http://dx.doi.org/10.1093/ehjcr/ytab383 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Report
Agarwal, Nayan
Rastogi, Ujjwal
Mahmoud, Ahmed N
Bhatt, Deepak L
A novel technique for invasive aortic valve pressure gradient measurement using a 6 Fr Swan-Ganz catheter: a case series
title A novel technique for invasive aortic valve pressure gradient measurement using a 6 Fr Swan-Ganz catheter: a case series
title_full A novel technique for invasive aortic valve pressure gradient measurement using a 6 Fr Swan-Ganz catheter: a case series
title_fullStr A novel technique for invasive aortic valve pressure gradient measurement using a 6 Fr Swan-Ganz catheter: a case series
title_full_unstemmed A novel technique for invasive aortic valve pressure gradient measurement using a 6 Fr Swan-Ganz catheter: a case series
title_short A novel technique for invasive aortic valve pressure gradient measurement using a 6 Fr Swan-Ganz catheter: a case series
title_sort novel technique for invasive aortic valve pressure gradient measurement using a 6 fr swan-ganz catheter: a case series
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495136/
https://www.ncbi.nlm.nih.gov/pubmed/34632266
http://dx.doi.org/10.1093/ehjcr/ytab383
work_keys_str_mv AT agarwalnayan anoveltechniqueforinvasiveaorticvalvepressuregradientmeasurementusinga6frswanganzcatheteracaseseries
AT rastogiujjwal anoveltechniqueforinvasiveaorticvalvepressuregradientmeasurementusinga6frswanganzcatheteracaseseries
AT mahmoudahmedn anoveltechniqueforinvasiveaorticvalvepressuregradientmeasurementusinga6frswanganzcatheteracaseseries
AT bhattdeepakl anoveltechniqueforinvasiveaorticvalvepressuregradientmeasurementusinga6frswanganzcatheteracaseseries
AT agarwalnayan noveltechniqueforinvasiveaorticvalvepressuregradientmeasurementusinga6frswanganzcatheteracaseseries
AT rastogiujjwal noveltechniqueforinvasiveaorticvalvepressuregradientmeasurementusinga6frswanganzcatheteracaseseries
AT mahmoudahmedn noveltechniqueforinvasiveaorticvalvepressuregradientmeasurementusinga6frswanganzcatheteracaseseries
AT bhattdeepakl noveltechniqueforinvasiveaorticvalvepressuregradientmeasurementusinga6frswanganzcatheteracaseseries