Cargando…

Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study

BACKGROUND: Limited research regarding administration of timed medication infusions in the prehospital environment has identified wide variability with accuracy, timing, and overall feasibility. This study was a quality improvement project that utilized a randomized, controlled, crossover study desi...

Descripción completa

Detalles Bibliográficos
Autores principales: Galvagno, Samuel M., Cloepin, James, Hannas, Jeannie, Rubach, Kurt S., Naumann, Andrew, Wendell, Jonathan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495908/
https://www.ncbi.nlm.nih.gov/pubmed/34620117
http://dx.doi.org/10.1186/s12873-021-00503-6
Descripción
Sumario:BACKGROUND: Limited research regarding administration of timed medication infusions in the prehospital environment has identified wide variability with accuracy, timing, and overall feasibility. This study was a quality improvement project that utilized a randomized, controlled, crossover study design to compare two different educational techniques for medication infusion administration. We hypothesized that the use of a metronome-based technique would decrease medication dosage errors and reduce time to administration for intravenous medication infusions. METHODS: Forty-two nationally registered paramedics were randomized to either a metronome-based technique versus a standard stopwatch-based technique. Each subject served as a control. Subjects were asked to establish an infusion of amiodarone at a dose of 150 mg administered over 10 min, simulating treatment of a hemodynamically stable patient with sustained monomorphic ventricular tachycardia. Descriptive statistics and a repeated measures mixed linear regression model were used for data analysis. RESULTS: When compared to a standard stopwatch-based technique, a metronome-based technique was associated with faster time to goal (median 34 s [IQR, 22–54] vs 50 s; [IQR 38–61 s], P = 0.006) and fewer mid-infusion adjustments. Ease of use was reported to be significantly higher for the metronome group (median ranking 5, IQR 4–5) compared to the standard group (median ranking 2, IQR 2–3; P < 0.001). CONCLUSIONS: Knowledge regarding a metronome technique may help EMS clinicians provide safe and effective IV infusions. Such a technique may be beneficial for learners and educators alike.