Cargando…

Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study

BACKGROUND: Limited research regarding administration of timed medication infusions in the prehospital environment has identified wide variability with accuracy, timing, and overall feasibility. This study was a quality improvement project that utilized a randomized, controlled, crossover study desi...

Descripción completa

Detalles Bibliográficos
Autores principales: Galvagno, Samuel M., Cloepin, James, Hannas, Jeannie, Rubach, Kurt S., Naumann, Andrew, Wendell, Jonathan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495908/
https://www.ncbi.nlm.nih.gov/pubmed/34620117
http://dx.doi.org/10.1186/s12873-021-00503-6
_version_ 1784579646664212480
author Galvagno, Samuel M.
Cloepin, James
Hannas, Jeannie
Rubach, Kurt S.
Naumann, Andrew
Wendell, Jonathan
author_facet Galvagno, Samuel M.
Cloepin, James
Hannas, Jeannie
Rubach, Kurt S.
Naumann, Andrew
Wendell, Jonathan
author_sort Galvagno, Samuel M.
collection PubMed
description BACKGROUND: Limited research regarding administration of timed medication infusions in the prehospital environment has identified wide variability with accuracy, timing, and overall feasibility. This study was a quality improvement project that utilized a randomized, controlled, crossover study design to compare two different educational techniques for medication infusion administration. We hypothesized that the use of a metronome-based technique would decrease medication dosage errors and reduce time to administration for intravenous medication infusions. METHODS: Forty-two nationally registered paramedics were randomized to either a metronome-based technique versus a standard stopwatch-based technique. Each subject served as a control. Subjects were asked to establish an infusion of amiodarone at a dose of 150 mg administered over 10 min, simulating treatment of a hemodynamically stable patient with sustained monomorphic ventricular tachycardia. Descriptive statistics and a repeated measures mixed linear regression model were used for data analysis. RESULTS: When compared to a standard stopwatch-based technique, a metronome-based technique was associated with faster time to goal (median 34 s [IQR, 22–54] vs 50 s; [IQR 38–61 s], P = 0.006) and fewer mid-infusion adjustments. Ease of use was reported to be significantly higher for the metronome group (median ranking 5, IQR 4–5) compared to the standard group (median ranking 2, IQR 2–3; P < 0.001). CONCLUSIONS: Knowledge regarding a metronome technique may help EMS clinicians provide safe and effective IV infusions. Such a technique may be beneficial for learners and educators alike.
format Online
Article
Text
id pubmed-8495908
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-84959082021-10-07 Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study Galvagno, Samuel M. Cloepin, James Hannas, Jeannie Rubach, Kurt S. Naumann, Andrew Wendell, Jonathan BMC Emerg Med Research BACKGROUND: Limited research regarding administration of timed medication infusions in the prehospital environment has identified wide variability with accuracy, timing, and overall feasibility. This study was a quality improvement project that utilized a randomized, controlled, crossover study design to compare two different educational techniques for medication infusion administration. We hypothesized that the use of a metronome-based technique would decrease medication dosage errors and reduce time to administration for intravenous medication infusions. METHODS: Forty-two nationally registered paramedics were randomized to either a metronome-based technique versus a standard stopwatch-based technique. Each subject served as a control. Subjects were asked to establish an infusion of amiodarone at a dose of 150 mg administered over 10 min, simulating treatment of a hemodynamically stable patient with sustained monomorphic ventricular tachycardia. Descriptive statistics and a repeated measures mixed linear regression model were used for data analysis. RESULTS: When compared to a standard stopwatch-based technique, a metronome-based technique was associated with faster time to goal (median 34 s [IQR, 22–54] vs 50 s; [IQR 38–61 s], P = 0.006) and fewer mid-infusion adjustments. Ease of use was reported to be significantly higher for the metronome group (median ranking 5, IQR 4–5) compared to the standard group (median ranking 2, IQR 2–3; P < 0.001). CONCLUSIONS: Knowledge regarding a metronome technique may help EMS clinicians provide safe and effective IV infusions. Such a technique may be beneficial for learners and educators alike. BioMed Central 2021-10-07 /pmc/articles/PMC8495908/ /pubmed/34620117 http://dx.doi.org/10.1186/s12873-021-00503-6 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Galvagno, Samuel M.
Cloepin, James
Hannas, Jeannie
Rubach, Kurt S.
Naumann, Andrew
Wendell, Jonathan
Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study
title Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study
title_full Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study
title_fullStr Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study
title_full_unstemmed Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study
title_short Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study
title_sort comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495908/
https://www.ncbi.nlm.nih.gov/pubmed/34620117
http://dx.doi.org/10.1186/s12873-021-00503-6
work_keys_str_mv AT galvagnosamuelm comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy
AT cloepinjames comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy
AT hannasjeannie comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy
AT rubachkurts comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy
AT naumannandrew comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy
AT wendelljonathan comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy