Cargando…
Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study
BACKGROUND: Limited research regarding administration of timed medication infusions in the prehospital environment has identified wide variability with accuracy, timing, and overall feasibility. This study was a quality improvement project that utilized a randomized, controlled, crossover study desi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495908/ https://www.ncbi.nlm.nih.gov/pubmed/34620117 http://dx.doi.org/10.1186/s12873-021-00503-6 |
_version_ | 1784579646664212480 |
---|---|
author | Galvagno, Samuel M. Cloepin, James Hannas, Jeannie Rubach, Kurt S. Naumann, Andrew Wendell, Jonathan |
author_facet | Galvagno, Samuel M. Cloepin, James Hannas, Jeannie Rubach, Kurt S. Naumann, Andrew Wendell, Jonathan |
author_sort | Galvagno, Samuel M. |
collection | PubMed |
description | BACKGROUND: Limited research regarding administration of timed medication infusions in the prehospital environment has identified wide variability with accuracy, timing, and overall feasibility. This study was a quality improvement project that utilized a randomized, controlled, crossover study design to compare two different educational techniques for medication infusion administration. We hypothesized that the use of a metronome-based technique would decrease medication dosage errors and reduce time to administration for intravenous medication infusions. METHODS: Forty-two nationally registered paramedics were randomized to either a metronome-based technique versus a standard stopwatch-based technique. Each subject served as a control. Subjects were asked to establish an infusion of amiodarone at a dose of 150 mg administered over 10 min, simulating treatment of a hemodynamically stable patient with sustained monomorphic ventricular tachycardia. Descriptive statistics and a repeated measures mixed linear regression model were used for data analysis. RESULTS: When compared to a standard stopwatch-based technique, a metronome-based technique was associated with faster time to goal (median 34 s [IQR, 22–54] vs 50 s; [IQR 38–61 s], P = 0.006) and fewer mid-infusion adjustments. Ease of use was reported to be significantly higher for the metronome group (median ranking 5, IQR 4–5) compared to the standard group (median ranking 2, IQR 2–3; P < 0.001). CONCLUSIONS: Knowledge regarding a metronome technique may help EMS clinicians provide safe and effective IV infusions. Such a technique may be beneficial for learners and educators alike. |
format | Online Article Text |
id | pubmed-8495908 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-84959082021-10-07 Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study Galvagno, Samuel M. Cloepin, James Hannas, Jeannie Rubach, Kurt S. Naumann, Andrew Wendell, Jonathan BMC Emerg Med Research BACKGROUND: Limited research regarding administration of timed medication infusions in the prehospital environment has identified wide variability with accuracy, timing, and overall feasibility. This study was a quality improvement project that utilized a randomized, controlled, crossover study design to compare two different educational techniques for medication infusion administration. We hypothesized that the use of a metronome-based technique would decrease medication dosage errors and reduce time to administration for intravenous medication infusions. METHODS: Forty-two nationally registered paramedics were randomized to either a metronome-based technique versus a standard stopwatch-based technique. Each subject served as a control. Subjects were asked to establish an infusion of amiodarone at a dose of 150 mg administered over 10 min, simulating treatment of a hemodynamically stable patient with sustained monomorphic ventricular tachycardia. Descriptive statistics and a repeated measures mixed linear regression model were used for data analysis. RESULTS: When compared to a standard stopwatch-based technique, a metronome-based technique was associated with faster time to goal (median 34 s [IQR, 22–54] vs 50 s; [IQR 38–61 s], P = 0.006) and fewer mid-infusion adjustments. Ease of use was reported to be significantly higher for the metronome group (median ranking 5, IQR 4–5) compared to the standard group (median ranking 2, IQR 2–3; P < 0.001). CONCLUSIONS: Knowledge regarding a metronome technique may help EMS clinicians provide safe and effective IV infusions. Such a technique may be beneficial for learners and educators alike. BioMed Central 2021-10-07 /pmc/articles/PMC8495908/ /pubmed/34620117 http://dx.doi.org/10.1186/s12873-021-00503-6 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Galvagno, Samuel M. Cloepin, James Hannas, Jeannie Rubach, Kurt S. Naumann, Andrew Wendell, Jonathan Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study |
title | Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study |
title_full | Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study |
title_fullStr | Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study |
title_full_unstemmed | Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study |
title_short | Comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study |
title_sort | comparison of a metronome-guided prehospital medication infusion technique with standard calculation: a simulated randomized, controlled, cross-over study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495908/ https://www.ncbi.nlm.nih.gov/pubmed/34620117 http://dx.doi.org/10.1186/s12873-021-00503-6 |
work_keys_str_mv | AT galvagnosamuelm comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy AT cloepinjames comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy AT hannasjeannie comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy AT rubachkurts comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy AT naumannandrew comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy AT wendelljonathan comparisonofametronomeguidedprehospitalmedicationinfusiontechniquewithstandardcalculationasimulatedrandomizedcontrolledcrossoverstudy |