Oxygen-Induced and pH-Induced Direct Current Artifacts on Invasive Platinum/Iridium Electrodes for Electrocorticography

BACKGROUND: Spreading depolarization (SD) and the initial, still reversible phase of neuronal cytotoxic edema in the cerebral gray matter are two modalities of the same process. SD may thus serve as a real-time mechanistic biomarker for impending parenchyma damage in patients during neurocritical ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Major, Sebastian, Gajovic-Eichelmann, Nenad, Woitzik, Johannes, Dreier, Jens P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8496677/
https://www.ncbi.nlm.nih.gov/pubmed/34622418
http://dx.doi.org/10.1007/s12028-021-01358-2
_version_ 1784579804145647616
author Major, Sebastian
Gajovic-Eichelmann, Nenad
Woitzik, Johannes
Dreier, Jens P.
author_facet Major, Sebastian
Gajovic-Eichelmann, Nenad
Woitzik, Johannes
Dreier, Jens P.
author_sort Major, Sebastian
collection PubMed
description BACKGROUND: Spreading depolarization (SD) and the initial, still reversible phase of neuronal cytotoxic edema in the cerebral gray matter are two modalities of the same process. SD may thus serve as a real-time mechanistic biomarker for impending parenchyma damage in patients during neurocritical care. Using subdural platinum/iridium (Pt/Ir) electrodes, SD is observed as a large negative direct current (DC) shift. Besides SD, there are other causes of DC shifts that are not to be confused with SD. Here, we systematically analyzed DC artifacts in ventilated patients by observing changes in the fraction of inspired oxygen. For the same change in blood oxygenation, we found that negative and positive DC shifts can simultaneously occur at adjacent Pt/Ir electrodes. METHODS: Nurses and intensivists typically increase blood oxygenation by increasing the fraction of inspired oxygen at the ventilator before performing manipulations on the patient. We retrospectively identified 20 such episodes in six patients via tissue partial pressure of oxygen (p(ti)O(2)) measurements with an intracortical O(2) sensor and analyzed the associated DC shifts. In vitro, we compared Pt/Ir with silver/silver chloride (Ag/AgCl) to assess DC responses to changes in pO(2), pH, or 5-min square voltage pulses and investigated the effect of electrode polarization on pO(2)-induced DC artifacts. RESULTS: Hyperoxygenation episodes started from a p(ti)O(2) of 37 (30–40) mmHg (median and interquartile range) reaching 71 (50–97) mmHg. During a total of 20 episodes on each of six subdural Pt/Ir electrodes in six patients, we observed 95 predominantly negative responses in six patients, 25 predominantly positive responses in four patients, and no brain activity changes. Adjacent electrodes could show positive and negative responses simultaneously. In vitro, Pt/Ir in contrast with Ag/AgCl responded to changes in either pO(2) or pH with large DC shifts. In response to square voltage pulses, Pt/Ir falsely showed smaller DC shifts than Ag/AgCl, with the worst performance under anoxia. In response to pO(2) increase, Pt/Ir showed DC positivity when positively polarized and DC negativity when negatively polarized. CONCLUSIONS: The magnitude of pO(2)-induced subdural DC shifts by approximately 6 mV was similar to that of SDs, but they did not show a sequential onset at adjacent recording sites, could be either predominantly negative or positive in contrast with the always negative DC shifts of SD, and were not accompanied by brain activity depression. Opposing polarities of pO(2)-induced DC artifacts may result from differences in baseline electrode polarization or subdural p(ti)O(2) inhomogeneities relative to subdermal p(ti)O(2) at the quasi-reference. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12028-021-01358-2.
format Online
Article
Text
id pubmed-8496677
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-84966772021-10-08 Oxygen-Induced and pH-Induced Direct Current Artifacts on Invasive Platinum/Iridium Electrodes for Electrocorticography Major, Sebastian Gajovic-Eichelmann, Nenad Woitzik, Johannes Dreier, Jens P. Neurocrit Care Spreading Cortical Depolarization BACKGROUND: Spreading depolarization (SD) and the initial, still reversible phase of neuronal cytotoxic edema in the cerebral gray matter are two modalities of the same process. SD may thus serve as a real-time mechanistic biomarker for impending parenchyma damage in patients during neurocritical care. Using subdural platinum/iridium (Pt/Ir) electrodes, SD is observed as a large negative direct current (DC) shift. Besides SD, there are other causes of DC shifts that are not to be confused with SD. Here, we systematically analyzed DC artifacts in ventilated patients by observing changes in the fraction of inspired oxygen. For the same change in blood oxygenation, we found that negative and positive DC shifts can simultaneously occur at adjacent Pt/Ir electrodes. METHODS: Nurses and intensivists typically increase blood oxygenation by increasing the fraction of inspired oxygen at the ventilator before performing manipulations on the patient. We retrospectively identified 20 such episodes in six patients via tissue partial pressure of oxygen (p(ti)O(2)) measurements with an intracortical O(2) sensor and analyzed the associated DC shifts. In vitro, we compared Pt/Ir with silver/silver chloride (Ag/AgCl) to assess DC responses to changes in pO(2), pH, or 5-min square voltage pulses and investigated the effect of electrode polarization on pO(2)-induced DC artifacts. RESULTS: Hyperoxygenation episodes started from a p(ti)O(2) of 37 (30–40) mmHg (median and interquartile range) reaching 71 (50–97) mmHg. During a total of 20 episodes on each of six subdural Pt/Ir electrodes in six patients, we observed 95 predominantly negative responses in six patients, 25 predominantly positive responses in four patients, and no brain activity changes. Adjacent electrodes could show positive and negative responses simultaneously. In vitro, Pt/Ir in contrast with Ag/AgCl responded to changes in either pO(2) or pH with large DC shifts. In response to square voltage pulses, Pt/Ir falsely showed smaller DC shifts than Ag/AgCl, with the worst performance under anoxia. In response to pO(2) increase, Pt/Ir showed DC positivity when positively polarized and DC negativity when negatively polarized. CONCLUSIONS: The magnitude of pO(2)-induced subdural DC shifts by approximately 6 mV was similar to that of SDs, but they did not show a sequential onset at adjacent recording sites, could be either predominantly negative or positive in contrast with the always negative DC shifts of SD, and were not accompanied by brain activity depression. Opposing polarities of pO(2)-induced DC artifacts may result from differences in baseline electrode polarization or subdural p(ti)O(2) inhomogeneities relative to subdermal p(ti)O(2) at the quasi-reference. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12028-021-01358-2. Springer US 2021-10-07 2021 /pmc/articles/PMC8496677/ /pubmed/34622418 http://dx.doi.org/10.1007/s12028-021-01358-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Spreading Cortical Depolarization
Major, Sebastian
Gajovic-Eichelmann, Nenad
Woitzik, Johannes
Dreier, Jens P.
Oxygen-Induced and pH-Induced Direct Current Artifacts on Invasive Platinum/Iridium Electrodes for Electrocorticography
title Oxygen-Induced and pH-Induced Direct Current Artifacts on Invasive Platinum/Iridium Electrodes for Electrocorticography
title_full Oxygen-Induced and pH-Induced Direct Current Artifacts on Invasive Platinum/Iridium Electrodes for Electrocorticography
title_fullStr Oxygen-Induced and pH-Induced Direct Current Artifacts on Invasive Platinum/Iridium Electrodes for Electrocorticography
title_full_unstemmed Oxygen-Induced and pH-Induced Direct Current Artifacts on Invasive Platinum/Iridium Electrodes for Electrocorticography
title_short Oxygen-Induced and pH-Induced Direct Current Artifacts on Invasive Platinum/Iridium Electrodes for Electrocorticography
title_sort oxygen-induced and ph-induced direct current artifacts on invasive platinum/iridium electrodes for electrocorticography
topic Spreading Cortical Depolarization
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8496677/
https://www.ncbi.nlm.nih.gov/pubmed/34622418
http://dx.doi.org/10.1007/s12028-021-01358-2
work_keys_str_mv AT majorsebastian oxygeninducedandphinduceddirectcurrentartifactsoninvasiveplatinumiridiumelectrodesforelectrocorticography
AT gajoviceichelmannnenad oxygeninducedandphinduceddirectcurrentartifactsoninvasiveplatinumiridiumelectrodesforelectrocorticography
AT woitzikjohannes oxygeninducedandphinduceddirectcurrentartifactsoninvasiveplatinumiridiumelectrodesforelectrocorticography
AT dreierjensp oxygeninducedandphinduceddirectcurrentartifactsoninvasiveplatinumiridiumelectrodesforelectrocorticography