Cargando…
Development and Validation of the Quantification Method for Hydroxychloroquine in Volumetric Absorptive Microsampling (VAMS) Using High-Performance Liquid Chromatography-Photodiode Array
Hydroxychloroquine is an antimalarial drug used for systemic lupus erythematosus, rheumatoid arthritis, and malaria treatment. However, hydroxychloroquine has several side effects such as ocular toxicity, neurotoxicity, gastrointestinal disorder, and also severe toxicity such as cardiotoxicity. Ther...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8497163/ https://www.ncbi.nlm.nih.gov/pubmed/34632395 http://dx.doi.org/10.1155/2021/3500279 |
_version_ | 1784579894658727936 |
---|---|
author | Harahap, Yahdiana Rohadatul ‘Aisy, Siti Ardyanti Maggadani, Baitha Palanggatan |
author_facet | Harahap, Yahdiana Rohadatul ‘Aisy, Siti Ardyanti Maggadani, Baitha Palanggatan |
author_sort | Harahap, Yahdiana |
collection | PubMed |
description | Hydroxychloroquine is an antimalarial drug used for systemic lupus erythematosus, rheumatoid arthritis, and malaria treatment. However, hydroxychloroquine has several side effects such as ocular toxicity, neurotoxicity, gastrointestinal disorder, and also severe toxicity such as cardiotoxicity. Therefore, therapeutic drug monitoring of high dose or long-term use of hydroxychloroquine is needed. This study aims to obtain an optimum and validated analysis and preparation method for hydroxychloroquine in volumetric absorptive microsampling (VAMS) using the high-performance liquid chromatography–photodiode array detector based on the Food and Drug Administration guidelines (2018). Hydroxychloroquine quantification was performed using HPLC-PDA with Waters Sunfire™ C(18) (5 µm; 250 × 4,6 mm) column. Mobile phase consists of acetonitrile-diethylamine 1% (65 : 35, v/v) (isocratic elution) and delivered at a flow rate of 0.8 mL/min throughout the 12 minutes run. Sample in VAMS is extracted by liquid-liquid extraction with ammonia 1% and n-hexane-ethyl acetate (50 : 50 v/v) as a extraction solvent. This method has successfully qualified the Food and Drug Administration (2018) parameters, with 2 ng/mL of LLOQ, range of calibration curve 2–6500 ng/mL, and coefficient of correlation 0.9993–0.9997. |
format | Online Article Text |
id | pubmed-8497163 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-84971632021-10-08 Development and Validation of the Quantification Method for Hydroxychloroquine in Volumetric Absorptive Microsampling (VAMS) Using High-Performance Liquid Chromatography-Photodiode Array Harahap, Yahdiana Rohadatul ‘Aisy, Siti Ardyanti Maggadani, Baitha Palanggatan Adv Pharmacol Pharm Sci Research Article Hydroxychloroquine is an antimalarial drug used for systemic lupus erythematosus, rheumatoid arthritis, and malaria treatment. However, hydroxychloroquine has several side effects such as ocular toxicity, neurotoxicity, gastrointestinal disorder, and also severe toxicity such as cardiotoxicity. Therefore, therapeutic drug monitoring of high dose or long-term use of hydroxychloroquine is needed. This study aims to obtain an optimum and validated analysis and preparation method for hydroxychloroquine in volumetric absorptive microsampling (VAMS) using the high-performance liquid chromatography–photodiode array detector based on the Food and Drug Administration guidelines (2018). Hydroxychloroquine quantification was performed using HPLC-PDA with Waters Sunfire™ C(18) (5 µm; 250 × 4,6 mm) column. Mobile phase consists of acetonitrile-diethylamine 1% (65 : 35, v/v) (isocratic elution) and delivered at a flow rate of 0.8 mL/min throughout the 12 minutes run. Sample in VAMS is extracted by liquid-liquid extraction with ammonia 1% and n-hexane-ethyl acetate (50 : 50 v/v) as a extraction solvent. This method has successfully qualified the Food and Drug Administration (2018) parameters, with 2 ng/mL of LLOQ, range of calibration curve 2–6500 ng/mL, and coefficient of correlation 0.9993–0.9997. Hindawi 2021-09-30 /pmc/articles/PMC8497163/ /pubmed/34632395 http://dx.doi.org/10.1155/2021/3500279 Text en Copyright © 2021 Yahdiana Harahap et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Harahap, Yahdiana Rohadatul ‘Aisy, Siti Ardyanti Maggadani, Baitha Palanggatan Development and Validation of the Quantification Method for Hydroxychloroquine in Volumetric Absorptive Microsampling (VAMS) Using High-Performance Liquid Chromatography-Photodiode Array |
title | Development and Validation of the Quantification Method for Hydroxychloroquine in Volumetric Absorptive Microsampling (VAMS) Using High-Performance Liquid Chromatography-Photodiode Array |
title_full | Development and Validation of the Quantification Method for Hydroxychloroquine in Volumetric Absorptive Microsampling (VAMS) Using High-Performance Liquid Chromatography-Photodiode Array |
title_fullStr | Development and Validation of the Quantification Method for Hydroxychloroquine in Volumetric Absorptive Microsampling (VAMS) Using High-Performance Liquid Chromatography-Photodiode Array |
title_full_unstemmed | Development and Validation of the Quantification Method for Hydroxychloroquine in Volumetric Absorptive Microsampling (VAMS) Using High-Performance Liquid Chromatography-Photodiode Array |
title_short | Development and Validation of the Quantification Method for Hydroxychloroquine in Volumetric Absorptive Microsampling (VAMS) Using High-Performance Liquid Chromatography-Photodiode Array |
title_sort | development and validation of the quantification method for hydroxychloroquine in volumetric absorptive microsampling (vams) using high-performance liquid chromatography-photodiode array |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8497163/ https://www.ncbi.nlm.nih.gov/pubmed/34632395 http://dx.doi.org/10.1155/2021/3500279 |
work_keys_str_mv | AT harahapyahdiana developmentandvalidationofthequantificationmethodforhydroxychloroquineinvolumetricabsorptivemicrosamplingvamsusinghighperformanceliquidchromatographyphotodiodearray AT rohadatulaisysitiardyanti developmentandvalidationofthequantificationmethodforhydroxychloroquineinvolumetricabsorptivemicrosamplingvamsusinghighperformanceliquidchromatographyphotodiodearray AT maggadanibaithapalanggatan developmentandvalidationofthequantificationmethodforhydroxychloroquineinvolumetricabsorptivemicrosamplingvamsusinghighperformanceliquidchromatographyphotodiodearray |