Cargando…
A Comparative Biomechanical Analysis of Various Rod Configurations Following Anterior Column Realignment and Pedicle Subtraction Osteotomy
OBJECTIVE: The objective of this study was to compare the biomechanical differences of different rod configurations following anterior column realignment (ACR) and pedicle subtraction osteotomy (PSO) for an optimal correction technique and rod configuration that would minimize the risk of rod failur...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Spinal Neurosurgery Society
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8497251/ https://www.ncbi.nlm.nih.gov/pubmed/34610690 http://dx.doi.org/10.14245/ns.2142450.225 |
_version_ | 1784579919293972480 |
---|---|
author | Mumtaz, Muzammil Mendoza, Justin Vosoughi, Ardalan Seyed Unger, Anthony S. Goel, Vijay K. |
author_facet | Mumtaz, Muzammil Mendoza, Justin Vosoughi, Ardalan Seyed Unger, Anthony S. Goel, Vijay K. |
author_sort | Mumtaz, Muzammil |
collection | PubMed |
description | OBJECTIVE: The objective of this study was to compare the biomechanical differences of different rod configurations following anterior column realignment (ACR) and pedicle subtraction osteotomy (PSO) for an optimal correction technique and rod configuration that would minimize the risk of rod failure. METHODS: A validated spinopelvic (L1-pelvis) finite element model was used to simulate ACR at the L3–4 level. The ACR procedure was followed by dual-rod fixation, and for 4-rod constructs, either medial/lateral accessory rods (connected to primary rods) or satellite rods (directly connected to ACR level screws). The range of motion (ROM), maximum von Mises stress on the rods, and factor of safety (FOS) were calculated for the ACR models and compared to the existing literature of different PSO rod configurations. RESULTS: All of the 4-rod ACR constructs showed a reduction in ROM and maximum von Mises stress compared to the dual-rod ACR construct. Additionally, all of the 4-rod ACR constructs showed greater percentage reduction in ROM and maximum von Mises stress compared to the PSO 4-rod configurations. The ACR satellite rod construct had the maximum stress reduction i.e., 47.3% compared to dual-rod construct and showed the highest FOS (4.76). These findings are consistent with existing literature that supports the use of satellite rods to reduce the occurrence of rod fracture. CONCLUSION: Our findings suggest that the ACR satellite rod construct may be the most beneficial in reducing the risk of rod failure compared to all other PSO and ACR constructs. |
format | Online Article Text |
id | pubmed-8497251 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Korean Spinal Neurosurgery Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-84972512021-10-15 A Comparative Biomechanical Analysis of Various Rod Configurations Following Anterior Column Realignment and Pedicle Subtraction Osteotomy Mumtaz, Muzammil Mendoza, Justin Vosoughi, Ardalan Seyed Unger, Anthony S. Goel, Vijay K. Neurospine Original Article OBJECTIVE: The objective of this study was to compare the biomechanical differences of different rod configurations following anterior column realignment (ACR) and pedicle subtraction osteotomy (PSO) for an optimal correction technique and rod configuration that would minimize the risk of rod failure. METHODS: A validated spinopelvic (L1-pelvis) finite element model was used to simulate ACR at the L3–4 level. The ACR procedure was followed by dual-rod fixation, and for 4-rod constructs, either medial/lateral accessory rods (connected to primary rods) or satellite rods (directly connected to ACR level screws). The range of motion (ROM), maximum von Mises stress on the rods, and factor of safety (FOS) were calculated for the ACR models and compared to the existing literature of different PSO rod configurations. RESULTS: All of the 4-rod ACR constructs showed a reduction in ROM and maximum von Mises stress compared to the dual-rod ACR construct. Additionally, all of the 4-rod ACR constructs showed greater percentage reduction in ROM and maximum von Mises stress compared to the PSO 4-rod configurations. The ACR satellite rod construct had the maximum stress reduction i.e., 47.3% compared to dual-rod construct and showed the highest FOS (4.76). These findings are consistent with existing literature that supports the use of satellite rods to reduce the occurrence of rod fracture. CONCLUSION: Our findings suggest that the ACR satellite rod construct may be the most beneficial in reducing the risk of rod failure compared to all other PSO and ACR constructs. Korean Spinal Neurosurgery Society 2021-09 2021-09-30 /pmc/articles/PMC8497251/ /pubmed/34610690 http://dx.doi.org/10.14245/ns.2142450.225 Text en Copyright © 2021 by the Korean Spinal Neurosurgery Society https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Mumtaz, Muzammil Mendoza, Justin Vosoughi, Ardalan Seyed Unger, Anthony S. Goel, Vijay K. A Comparative Biomechanical Analysis of Various Rod Configurations Following Anterior Column Realignment and Pedicle Subtraction Osteotomy |
title | A Comparative Biomechanical Analysis of Various Rod Configurations Following Anterior Column Realignment and Pedicle Subtraction Osteotomy |
title_full | A Comparative Biomechanical Analysis of Various Rod Configurations Following Anterior Column Realignment and Pedicle Subtraction Osteotomy |
title_fullStr | A Comparative Biomechanical Analysis of Various Rod Configurations Following Anterior Column Realignment and Pedicle Subtraction Osteotomy |
title_full_unstemmed | A Comparative Biomechanical Analysis of Various Rod Configurations Following Anterior Column Realignment and Pedicle Subtraction Osteotomy |
title_short | A Comparative Biomechanical Analysis of Various Rod Configurations Following Anterior Column Realignment and Pedicle Subtraction Osteotomy |
title_sort | comparative biomechanical analysis of various rod configurations following anterior column realignment and pedicle subtraction osteotomy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8497251/ https://www.ncbi.nlm.nih.gov/pubmed/34610690 http://dx.doi.org/10.14245/ns.2142450.225 |
work_keys_str_mv | AT mumtazmuzammil acomparativebiomechanicalanalysisofvariousrodconfigurationsfollowinganteriorcolumnrealignmentandpediclesubtractionosteotomy AT mendozajustin acomparativebiomechanicalanalysisofvariousrodconfigurationsfollowinganteriorcolumnrealignmentandpediclesubtractionosteotomy AT vosoughiardalanseyed acomparativebiomechanicalanalysisofvariousrodconfigurationsfollowinganteriorcolumnrealignmentandpediclesubtractionosteotomy AT ungeranthonys acomparativebiomechanicalanalysisofvariousrodconfigurationsfollowinganteriorcolumnrealignmentandpediclesubtractionosteotomy AT goelvijayk acomparativebiomechanicalanalysisofvariousrodconfigurationsfollowinganteriorcolumnrealignmentandpediclesubtractionosteotomy AT mumtazmuzammil comparativebiomechanicalanalysisofvariousrodconfigurationsfollowinganteriorcolumnrealignmentandpediclesubtractionosteotomy AT mendozajustin comparativebiomechanicalanalysisofvariousrodconfigurationsfollowinganteriorcolumnrealignmentandpediclesubtractionosteotomy AT vosoughiardalanseyed comparativebiomechanicalanalysisofvariousrodconfigurationsfollowinganteriorcolumnrealignmentandpediclesubtractionosteotomy AT ungeranthonys comparativebiomechanicalanalysisofvariousrodconfigurationsfollowinganteriorcolumnrealignmentandpediclesubtractionosteotomy AT goelvijayk comparativebiomechanicalanalysisofvariousrodconfigurationsfollowinganteriorcolumnrealignmentandpediclesubtractionosteotomy |