Cargando…
Influence of Lumbar Lordosis on Posterior Rod Strain in Long-Segment Construct During Biomechanical Loading: A Cadaveric Study
OBJECTIVE: The lordotic shape of the lumbar spine differs substantially between individuals. Measuring and recording strain during spinal biomechanical tests is an effective method to infer stresses on spinal implants and predict failure mechanisms. The geometry of the spine may have a significant e...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Spinal Neurosurgery Society
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8497261/ https://www.ncbi.nlm.nih.gov/pubmed/34610695 http://dx.doi.org/10.14245/ns.2142368.184 |
_version_ | 1784579922133516288 |
---|---|
author | de Andrada Pereira, Bernardo Sawa, Anna G.U. Godzik, Jakub Lehrman, Jennifer N. Uribe, Juan S. Turner, Jay D. Kelly, Brian P. |
author_facet | de Andrada Pereira, Bernardo Sawa, Anna G.U. Godzik, Jakub Lehrman, Jennifer N. Uribe, Juan S. Turner, Jay D. Kelly, Brian P. |
author_sort | de Andrada Pereira, Bernardo |
collection | PubMed |
description | OBJECTIVE: The lordotic shape of the lumbar spine differs substantially between individuals. Measuring and recording strain during spinal biomechanical tests is an effective method to infer stresses on spinal implants and predict failure mechanisms. The geometry of the spine may have a significant effect on the resultant force distribution, thereby directly affecting rod strain. METHODS: Seven fresh-frozen cadaveric specimens (T12-sacrum) underwent standard (7.5 Nm) nondestructive sagittal plane tests: flexion and extension. The conditions tested were intact and pedicle screws and rods (PSR) at L1-sacrum. The posterior right rod was instrumented with strain gauges between L3–4 (index level) and the L5–S1 pedicle screw. All specimens underwent lateral radiographs before testing. Lordotic angles encompassing different levels (L5–S1, L4–S1, L3–S1, L2–S1, and L1–S1) were measured and compared with rod strain. Data were analyzed using Pearson correlation analyses. RESULTS: Strong positive correlations were observed between lordosis and posterior rod strain across different conditions. The L3–S1 lordotic angle in the unloaded intact condition correlated with peak rod strain at L3–4 with PSR during flexion (R=0.76, p=0.04). The same angle in the unloaded PSR condition correlated with peak strain in the PSR condition during extension (R=-0.79, p=0.04). The unloaded intact L2–S1 lordotic angle was significantly correlated with rod strain at L3–4 in the PSR condition during flexion (R=0.85, p=0.02) and extension (R=-0.85, p=0.02) and with rod strain at L5–S1 in the PSR condition during flexion (R=0.84, p=0.04). CONCLUSION: Lordosis measured on intact and instrumented conditions has strong positive correlations with posterior rod strain in cadaveric testing. |
format | Online Article Text |
id | pubmed-8497261 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Korean Spinal Neurosurgery Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-84972612021-10-15 Influence of Lumbar Lordosis on Posterior Rod Strain in Long-Segment Construct During Biomechanical Loading: A Cadaveric Study de Andrada Pereira, Bernardo Sawa, Anna G.U. Godzik, Jakub Lehrman, Jennifer N. Uribe, Juan S. Turner, Jay D. Kelly, Brian P. Neurospine Original Article OBJECTIVE: The lordotic shape of the lumbar spine differs substantially between individuals. Measuring and recording strain during spinal biomechanical tests is an effective method to infer stresses on spinal implants and predict failure mechanisms. The geometry of the spine may have a significant effect on the resultant force distribution, thereby directly affecting rod strain. METHODS: Seven fresh-frozen cadaveric specimens (T12-sacrum) underwent standard (7.5 Nm) nondestructive sagittal plane tests: flexion and extension. The conditions tested were intact and pedicle screws and rods (PSR) at L1-sacrum. The posterior right rod was instrumented with strain gauges between L3–4 (index level) and the L5–S1 pedicle screw. All specimens underwent lateral radiographs before testing. Lordotic angles encompassing different levels (L5–S1, L4–S1, L3–S1, L2–S1, and L1–S1) were measured and compared with rod strain. Data were analyzed using Pearson correlation analyses. RESULTS: Strong positive correlations were observed between lordosis and posterior rod strain across different conditions. The L3–S1 lordotic angle in the unloaded intact condition correlated with peak rod strain at L3–4 with PSR during flexion (R=0.76, p=0.04). The same angle in the unloaded PSR condition correlated with peak strain in the PSR condition during extension (R=-0.79, p=0.04). The unloaded intact L2–S1 lordotic angle was significantly correlated with rod strain at L3–4 in the PSR condition during flexion (R=0.85, p=0.02) and extension (R=-0.85, p=0.02) and with rod strain at L5–S1 in the PSR condition during flexion (R=0.84, p=0.04). CONCLUSION: Lordosis measured on intact and instrumented conditions has strong positive correlations with posterior rod strain in cadaveric testing. Korean Spinal Neurosurgery Society 2021-09 2021-09-30 /pmc/articles/PMC8497261/ /pubmed/34610695 http://dx.doi.org/10.14245/ns.2142368.184 Text en Copyright © 2021 by the Korean Spinal Neurosurgery Society https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article de Andrada Pereira, Bernardo Sawa, Anna G.U. Godzik, Jakub Lehrman, Jennifer N. Uribe, Juan S. Turner, Jay D. Kelly, Brian P. Influence of Lumbar Lordosis on Posterior Rod Strain in Long-Segment Construct During Biomechanical Loading: A Cadaveric Study |
title | Influence of Lumbar Lordosis on Posterior Rod Strain in Long-Segment Construct During Biomechanical Loading: A Cadaveric Study |
title_full | Influence of Lumbar Lordosis on Posterior Rod Strain in Long-Segment Construct During Biomechanical Loading: A Cadaveric Study |
title_fullStr | Influence of Lumbar Lordosis on Posterior Rod Strain in Long-Segment Construct During Biomechanical Loading: A Cadaveric Study |
title_full_unstemmed | Influence of Lumbar Lordosis on Posterior Rod Strain in Long-Segment Construct During Biomechanical Loading: A Cadaveric Study |
title_short | Influence of Lumbar Lordosis on Posterior Rod Strain in Long-Segment Construct During Biomechanical Loading: A Cadaveric Study |
title_sort | influence of lumbar lordosis on posterior rod strain in long-segment construct during biomechanical loading: a cadaveric study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8497261/ https://www.ncbi.nlm.nih.gov/pubmed/34610695 http://dx.doi.org/10.14245/ns.2142368.184 |
work_keys_str_mv | AT deandradapereirabernardo influenceoflumbarlordosisonposteriorrodstraininlongsegmentconstructduringbiomechanicalloadingacadavericstudy AT sawaannagu influenceoflumbarlordosisonposteriorrodstraininlongsegmentconstructduringbiomechanicalloadingacadavericstudy AT godzikjakub influenceoflumbarlordosisonposteriorrodstraininlongsegmentconstructduringbiomechanicalloadingacadavericstudy AT lehrmanjennifern influenceoflumbarlordosisonposteriorrodstraininlongsegmentconstructduringbiomechanicalloadingacadavericstudy AT uribejuans influenceoflumbarlordosisonposteriorrodstraininlongsegmentconstructduringbiomechanicalloadingacadavericstudy AT turnerjayd influenceoflumbarlordosisonposteriorrodstraininlongsegmentconstructduringbiomechanicalloadingacadavericstudy AT kellybrianp influenceoflumbarlordosisonposteriorrodstraininlongsegmentconstructduringbiomechanicalloadingacadavericstudy |