Cargando…
Using 4DCBCT simulation and guidance to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe
Inter-fractional tumor variance would lead to insufficient dosage or overdose in tumor region during lung cancer radiotherapy. However, previous works have not considered influence of inter-fractional tumor amplitude variance at treatment position due to lack of effective evaluation method during ra...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8497481/ https://www.ncbi.nlm.nih.gov/pubmed/34620950 http://dx.doi.org/10.1038/s41598-021-99489-1 |
_version_ | 1784579961534808064 |
---|---|
author | Li, Yi Wu, Wenjing He, Ruixin Lu, Yongkai Zhang, Yuemei Wang, Long Zhang, Xiaozhi |
author_facet | Li, Yi Wu, Wenjing He, Ruixin Lu, Yongkai Zhang, Yuemei Wang, Long Zhang, Xiaozhi |
author_sort | Li, Yi |
collection | PubMed |
description | Inter-fractional tumor variance would lead to insufficient dosage or overdose in tumor region during lung cancer radiotherapy. However, previous works have not considered influence of inter-fractional tumor amplitude variance at treatment position due to lack of effective evaluation method during radiotherapy, especially for lung tumor within the lower lobe. Our objective was to investigate inter-fractional tumor baseline shift and amplitude variance due to respiratory motion with 4DCBCT simulation and guidance during stereotactic ablative body radiotherapy (SABR) for lung tumor. Subject included 19 patients with lung tumor within the lower lobe. 4DCBCT-simulated images at treatment position were acquired sequentially to determine internal tumor volume (ITV) and reference tumor motion at simulation process. Compared with reference tumor motion, 95 4DCBCT-guided images were acquired during each treatment to evaluate inter-fractional tumor baseline shift and amplitude variance, which were − 0.0 ± 1.3 mm and − 0.2 ± 1.4 mm in left–right(LR) direction, 0.9 ± 2.3 mm and 0.4 ± 2.9 mm in superior-inferior (SI) direction, 0.1 ± 1.5 mm and − 0.4 ± 2.0 mm in anterior–posterior (AP) direction. ITV margin were 3.5 mm, 7.5 mm and 5.3 mm in LR, SI and AP directions with van Herk’s (Int J Radiat Oncol Biol Phys 52(5):1407–1422, 2002) formula. 4DCBCT simulation and guidance is a reliable method to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe. ITV margin of 3.5 mm, 7.5 mm and 5.3 mm in LR, SI and AP directions would ensure greater tumor coverage during SABR for lung tumor within the lower lobe. |
format | Online Article Text |
id | pubmed-8497481 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-84974812021-10-08 Using 4DCBCT simulation and guidance to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe Li, Yi Wu, Wenjing He, Ruixin Lu, Yongkai Zhang, Yuemei Wang, Long Zhang, Xiaozhi Sci Rep Article Inter-fractional tumor variance would lead to insufficient dosage or overdose in tumor region during lung cancer radiotherapy. However, previous works have not considered influence of inter-fractional tumor amplitude variance at treatment position due to lack of effective evaluation method during radiotherapy, especially for lung tumor within the lower lobe. Our objective was to investigate inter-fractional tumor baseline shift and amplitude variance due to respiratory motion with 4DCBCT simulation and guidance during stereotactic ablative body radiotherapy (SABR) for lung tumor. Subject included 19 patients with lung tumor within the lower lobe. 4DCBCT-simulated images at treatment position were acquired sequentially to determine internal tumor volume (ITV) and reference tumor motion at simulation process. Compared with reference tumor motion, 95 4DCBCT-guided images were acquired during each treatment to evaluate inter-fractional tumor baseline shift and amplitude variance, which were − 0.0 ± 1.3 mm and − 0.2 ± 1.4 mm in left–right(LR) direction, 0.9 ± 2.3 mm and 0.4 ± 2.9 mm in superior-inferior (SI) direction, 0.1 ± 1.5 mm and − 0.4 ± 2.0 mm in anterior–posterior (AP) direction. ITV margin were 3.5 mm, 7.5 mm and 5.3 mm in LR, SI and AP directions with van Herk’s (Int J Radiat Oncol Biol Phys 52(5):1407–1422, 2002) formula. 4DCBCT simulation and guidance is a reliable method to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe. ITV margin of 3.5 mm, 7.5 mm and 5.3 mm in LR, SI and AP directions would ensure greater tumor coverage during SABR for lung tumor within the lower lobe. Nature Publishing Group UK 2021-10-07 /pmc/articles/PMC8497481/ /pubmed/34620950 http://dx.doi.org/10.1038/s41598-021-99489-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Li, Yi Wu, Wenjing He, Ruixin Lu, Yongkai Zhang, Yuemei Wang, Long Zhang, Xiaozhi Using 4DCBCT simulation and guidance to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe |
title | Using 4DCBCT simulation and guidance to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe |
title_full | Using 4DCBCT simulation and guidance to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe |
title_fullStr | Using 4DCBCT simulation and guidance to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe |
title_full_unstemmed | Using 4DCBCT simulation and guidance to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe |
title_short | Using 4DCBCT simulation and guidance to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe |
title_sort | using 4dcbct simulation and guidance to evaluate inter-fractional tumor variance during sabr for lung tumor within the lower lobe |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8497481/ https://www.ncbi.nlm.nih.gov/pubmed/34620950 http://dx.doi.org/10.1038/s41598-021-99489-1 |
work_keys_str_mv | AT liyi using4dcbctsimulationandguidancetoevaluateinterfractionaltumorvarianceduringsabrforlungtumorwithinthelowerlobe AT wuwenjing using4dcbctsimulationandguidancetoevaluateinterfractionaltumorvarianceduringsabrforlungtumorwithinthelowerlobe AT heruixin using4dcbctsimulationandguidancetoevaluateinterfractionaltumorvarianceduringsabrforlungtumorwithinthelowerlobe AT luyongkai using4dcbctsimulationandguidancetoevaluateinterfractionaltumorvarianceduringsabrforlungtumorwithinthelowerlobe AT zhangyuemei using4dcbctsimulationandguidancetoevaluateinterfractionaltumorvarianceduringsabrforlungtumorwithinthelowerlobe AT wanglong using4dcbctsimulationandguidancetoevaluateinterfractionaltumorvarianceduringsabrforlungtumorwithinthelowerlobe AT zhangxiaozhi using4dcbctsimulationandguidancetoevaluateinterfractionaltumorvarianceduringsabrforlungtumorwithinthelowerlobe |