Cargando…

Comparison of a ready-to-use liquid glucagon injection administered by autoinjector to glucagon emergency kit for the symptomatic relief of severe hypoglycemia: two randomized crossover non-inferiority studies

INTRODUCTION: To prevent medical sequelae of severe hypoglycemic emergencies, prompt and reliable rescue intervention is critically important. A ready-to-use, liquid stable glucagon, administered subcutaneously by glucagon autoinjector (GAI), Gvoke HypoPen (glucagon injection; Xeris Pharmaceuticals)...

Descripción completa

Detalles Bibliográficos
Autores principales: Christiansen, Mark P, Cummins, Martin, Prestrelski, Steven, Close, Nicole C, Nguyen, Anh, Junaidi, Khaled
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8499286/
https://www.ncbi.nlm.nih.gov/pubmed/34620618
http://dx.doi.org/10.1136/bmjdrc-2021-002137
_version_ 1784580300383191040
author Christiansen, Mark P
Cummins, Martin
Prestrelski, Steven
Close, Nicole C
Nguyen, Anh
Junaidi, Khaled
author_facet Christiansen, Mark P
Cummins, Martin
Prestrelski, Steven
Close, Nicole C
Nguyen, Anh
Junaidi, Khaled
author_sort Christiansen, Mark P
collection PubMed
description INTRODUCTION: To prevent medical sequelae of severe hypoglycemic emergencies, prompt and reliable rescue intervention is critically important. A ready-to-use, liquid stable glucagon, administered subcutaneously by glucagon autoinjector (GAI), Gvoke HypoPen (glucagon injection; Xeris Pharmaceuticals), was evaluated for rescue treatment of severe hypoglycemia. RESEARCH DESIGN AND METHODS: Two phase III, randomized, controlled, blinded, non-inferiority crossover studies were conducted in 161 adults with type 1 diabetes to compare 1 mg doses of GAI versus glucagon emergency kit (GEK) for treating insulin-induced severe hypoglycemia. Efficacy was evaluated as either a return of plasma glucose to >70 mg/dL (3.9 mmol/L) or increase ≥20 mg/dL (1.1 mmol/L) from a baseline glucose of <50 mg/dL (2.9 mmol/L), within 30 min of dosing. RESULTS: For successful plasma glucose recovery within 30 min, treatment with GAI was non-inferior to GEK. Treatment with GAI was non-inferior to GEK for a plasma glucose >70 mg/dL (3.9 mmol/L) or neuroglycopenic symptom relief within 30 min. From administration of glucagon, the mean time to achieve plasma glucose >70 mg/dL (3.9 mmol/L) or increase ≥20 mg/dL (1.1 mmol/L) was 13.8±5.6 min for GAI and 10.0±3.6 min for GEK. This mean time does not account for the significantly shorter (p<0.0001) drug preparation and administration time for GAI (27.3±19.7 s) versus GEK (97.2±45.1 s). The incidence of treatment emergent adverse events was comparable in both groups. CONCLUSIONS: A ready-to-use GAI was non-inferior to GEK, with a similar tolerability profile. GAI is an effective, safe, and well-tolerated rescue treatment for severe hypoglycemia and is a viable alternative to GEK. TRIAL REGISTRATION NUMBERS: NCT02656069 and NCT03439072.
format Online
Article
Text
id pubmed-8499286
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-84992862021-10-22 Comparison of a ready-to-use liquid glucagon injection administered by autoinjector to glucagon emergency kit for the symptomatic relief of severe hypoglycemia: two randomized crossover non-inferiority studies Christiansen, Mark P Cummins, Martin Prestrelski, Steven Close, Nicole C Nguyen, Anh Junaidi, Khaled BMJ Open Diabetes Res Care Emerging Technologies, Pharmacology and Therapeutics INTRODUCTION: To prevent medical sequelae of severe hypoglycemic emergencies, prompt and reliable rescue intervention is critically important. A ready-to-use, liquid stable glucagon, administered subcutaneously by glucagon autoinjector (GAI), Gvoke HypoPen (glucagon injection; Xeris Pharmaceuticals), was evaluated for rescue treatment of severe hypoglycemia. RESEARCH DESIGN AND METHODS: Two phase III, randomized, controlled, blinded, non-inferiority crossover studies were conducted in 161 adults with type 1 diabetes to compare 1 mg doses of GAI versus glucagon emergency kit (GEK) for treating insulin-induced severe hypoglycemia. Efficacy was evaluated as either a return of plasma glucose to >70 mg/dL (3.9 mmol/L) or increase ≥20 mg/dL (1.1 mmol/L) from a baseline glucose of <50 mg/dL (2.9 mmol/L), within 30 min of dosing. RESULTS: For successful plasma glucose recovery within 30 min, treatment with GAI was non-inferior to GEK. Treatment with GAI was non-inferior to GEK for a plasma glucose >70 mg/dL (3.9 mmol/L) or neuroglycopenic symptom relief within 30 min. From administration of glucagon, the mean time to achieve plasma glucose >70 mg/dL (3.9 mmol/L) or increase ≥20 mg/dL (1.1 mmol/L) was 13.8±5.6 min for GAI and 10.0±3.6 min for GEK. This mean time does not account for the significantly shorter (p<0.0001) drug preparation and administration time for GAI (27.3±19.7 s) versus GEK (97.2±45.1 s). The incidence of treatment emergent adverse events was comparable in both groups. CONCLUSIONS: A ready-to-use GAI was non-inferior to GEK, with a similar tolerability profile. GAI is an effective, safe, and well-tolerated rescue treatment for severe hypoglycemia and is a viable alternative to GEK. TRIAL REGISTRATION NUMBERS: NCT02656069 and NCT03439072. BMJ Publishing Group 2021-10-07 /pmc/articles/PMC8499286/ /pubmed/34620618 http://dx.doi.org/10.1136/bmjdrc-2021-002137 Text en © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Emerging Technologies, Pharmacology and Therapeutics
Christiansen, Mark P
Cummins, Martin
Prestrelski, Steven
Close, Nicole C
Nguyen, Anh
Junaidi, Khaled
Comparison of a ready-to-use liquid glucagon injection administered by autoinjector to glucagon emergency kit for the symptomatic relief of severe hypoglycemia: two randomized crossover non-inferiority studies
title Comparison of a ready-to-use liquid glucagon injection administered by autoinjector to glucagon emergency kit for the symptomatic relief of severe hypoglycemia: two randomized crossover non-inferiority studies
title_full Comparison of a ready-to-use liquid glucagon injection administered by autoinjector to glucagon emergency kit for the symptomatic relief of severe hypoglycemia: two randomized crossover non-inferiority studies
title_fullStr Comparison of a ready-to-use liquid glucagon injection administered by autoinjector to glucagon emergency kit for the symptomatic relief of severe hypoglycemia: two randomized crossover non-inferiority studies
title_full_unstemmed Comparison of a ready-to-use liquid glucagon injection administered by autoinjector to glucagon emergency kit for the symptomatic relief of severe hypoglycemia: two randomized crossover non-inferiority studies
title_short Comparison of a ready-to-use liquid glucagon injection administered by autoinjector to glucagon emergency kit for the symptomatic relief of severe hypoglycemia: two randomized crossover non-inferiority studies
title_sort comparison of a ready-to-use liquid glucagon injection administered by autoinjector to glucagon emergency kit for the symptomatic relief of severe hypoglycemia: two randomized crossover non-inferiority studies
topic Emerging Technologies, Pharmacology and Therapeutics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8499286/
https://www.ncbi.nlm.nih.gov/pubmed/34620618
http://dx.doi.org/10.1136/bmjdrc-2021-002137
work_keys_str_mv AT christiansenmarkp comparisonofareadytouseliquidglucagoninjectionadministeredbyautoinjectortoglucagonemergencykitforthesymptomaticreliefofseverehypoglycemiatworandomizedcrossovernoninferioritystudies
AT cumminsmartin comparisonofareadytouseliquidglucagoninjectionadministeredbyautoinjectortoglucagonemergencykitforthesymptomaticreliefofseverehypoglycemiatworandomizedcrossovernoninferioritystudies
AT prestrelskisteven comparisonofareadytouseliquidglucagoninjectionadministeredbyautoinjectortoglucagonemergencykitforthesymptomaticreliefofseverehypoglycemiatworandomizedcrossovernoninferioritystudies
AT closenicolec comparisonofareadytouseliquidglucagoninjectionadministeredbyautoinjectortoglucagonemergencykitforthesymptomaticreliefofseverehypoglycemiatworandomizedcrossovernoninferioritystudies
AT nguyenanh comparisonofareadytouseliquidglucagoninjectionadministeredbyautoinjectortoglucagonemergencykitforthesymptomaticreliefofseverehypoglycemiatworandomizedcrossovernoninferioritystudies
AT junaidikhaled comparisonofareadytouseliquidglucagoninjectionadministeredbyautoinjectortoglucagonemergencykitforthesymptomaticreliefofseverehypoglycemiatworandomizedcrossovernoninferioritystudies